Environmental Specifications; Power Specifications - Cisco CPS-UCS-2RU-K9 User Manual

Css ucs platform series
Table of Contents

Advertisement

Cisco Connected Safety and Security UCS C220 (1RU) Specifications

Environmental Specifications

Table A-2
Table A-2
Description
Temperature, operating:
Temperature, non-operating
Humidity (RH), noncondensing
Altitude, operating
Altitude, non-operating
Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)
Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)

Power Specifications

Up to two 650 W power supplies are supported, including 1+1 redundancy (the 450W is not supported).
Note
Table A-3
Table A-3
Description
AC input voltage range
AC input frequency
AC line input current (steady state)
Maximum output power for each power
supply
Power supply output voltage
Cisco CSS UCS Platform Series User Guide, CPS-UCS-1RU-K9 / CPS-UCS-2RU-K9
A-2
lists the environmental specifications for the server.
Environmental Specifications
You can get more specific power information for your exact server configuration by using the Cisco
UCS Power Calculator:
http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/
Do not mix power supply types in the server. Both power supplies must be 650W (the 450W is not
supported).
lists the specifications for each 650W power supply (Cisco part number CPS-PSU-650W=).
Power Supply Specifications
Appendix A
Specification
41 to 104°F (5 to 40°C)
Derate the maximum temperature by 1°C per every
305 meters of altitude above sea level.
–40 to 149°F (–40 to 65°C)
10 to 90%
0 to 10,000 feet
0 to 40,000 feet
5.4
37
Specification
90 to 264 VAC (self-ranging, 180 to 264 VAC nominal)
Range: 47 to 63 Hz (single phase, 50 to 60Hz nominal)
7.6 A peak at 100 VAC
3.65 A peak at 208 VAC
650 W
Main power: 12 VDC
Standby power: 12 VDC
Server Specifications

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cps-ucs-1ru-k9

Table of Contents