Bodet BT6000 Installation And Use Manual page 24

Scoreboard
Hide thumbs Also See for BT6000:
Table of Contents

Advertisement

Netball
Sport rules
Netball
1: 4 x 15 min
Netball
2: 2 x 20 min
All these parameters are modifiable with the configuration programme for each type.
ý 12:34 &
[[[
6
- Countdown of rest times if programmed.
- Reset of scores in black if correction score to zero.
N.B.: rest times can be stopped during the working out by pressing on "Start/Stop" key and the time break on
"time break" key corresponding. At the end of working out of those times, the game timer does not start up
automatically. Start up by pressing "Start/Stop" key.
The pre-recorded configuration for each sport can be modified. Select and validate a sport and a type of rules Hold down
the SEL (8) key to access to the configuration menu :
- Press the + or – (13) keys to modify the values of each parameter.
- Press the RIGHT (13) key to scroll down through all the parameters
- Press the LEFT (13) key to scroll up
- Press the OK (11) key to save the new parameters and return to the display of the match.
Rule 1
Period duration
/game
:
15 min
Period Number
/game
:
4
Time out
duration
:
60 sec
Horn before time
out end
:
10 sec
Extra time
duration
:
0 min
Keep display
result
:
60sec
Horn
duration
:
3 sec
Factory
data
load
: No
24
Game in 4 periods of 15 minutes - 3 time outs of 1 minute - Auto. horn.
Game in 2 periods of 20 minutes - 3 time outs of 1 minute - Auto. horn.
Main keyboard VDU
2/4
3
]]]
Between the game periods
Configuration menu per sport
Rule 2
Parameters
1 to 90 minutes
20 min
1 to 9 periods
2
0 to 99 seconds
60 sec
0 to 99 seconds
10 sec
0 to 90 minutes
0 min
0 to 60 seconds by
60 sec
step of 10 sec
0 to 5 seconds
3 sec
Yes or No
No
Designation
Counting of rest time.
Playing time.
Timer stopped indicator.
ÿ
Auto. horn indicator.
Visiting team time outs indicator.
Visiting team score.
Period or time out countdown.
Home team score.
Home team time outs indicator.
Select game period duration.
Select number of game period.
Select time out duration.
If = 0, no automatic horn.
If > 0, signal with a short blast at the next end of time out.
Selection of extra time period of match if there is a tie.
If = 0, no extra time.
Maintains display of the last period for a programmable time if the break time is
not counted down.
If = 0, no automatic horn.
If > 0, limit the duration of the horn's ringing for reduce the sound level in the
room.
If YES, reload the values of parameters as provided on putting the display board
into service.
Description
3/3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents