Timer Control; Dmx 512 Connection - Beamz S2500 Instruction Manual

Dmx led 24x10w 4in1
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
DISPLAY
Via the Menu key, you can adjust the desired settings. After pressing the menu, the display shows the following settings:
1.
Man Vol Out xxx%.
Adjust the manual volume output within the range of 0% to 100% by means
of the Up/Down keys.
2.
Interval Set xxxS
Adjust the interval between each fog emission within the range of 1 to 100S
by means of the Up-/Down keys.
3.
Duration Set xxxS
Adjust the duration of each fog emission within the range of 1 to 100S.
4.
Volume Out xxx%
Adjust the volume output during the timer function within the range of 0-
100%
5.
DMX 512 #xxx
Adjust the DMX address for DMX control.
6.
Wind For Class xx
NO FUNCTION for this model.
7.
Angel Set xx%
NO FUNCTION for this model.
8.
LED Pro Set xx
Adjust the LED program within the range of 0 to 11.
9.
LED Spe xxx
Adjust the LED speed/strobe/fade of the LED program mode
10. Temper Max:xxx
Adjust the maximum heating temperature of the heating element, adjustable between 285° - 330°C.
11. LED Sync Set Yes/No
Adjust the LED mode. Yes=LEDs work together with the smoke output, NO=LEDs are always on.

TIMER CONTROL

Press the Timer key to activate the timer function. The display shows the adjusted interval and the device counts the seconds
down to "0". After that, the fog emission is triggered at the volume adjusted under "Volume Out". The duration depends on the
settings adjusted under "Duration Set". If you wish to deactivate the timer function, press the Timer key once more.
Manual control (locked)
Press the Lock button for immediate triggering of the fog emission at the volume adjusted under "Man Volume". Press the lock
button more in order to stop the fog emission.
Manual control (100% output)
Press the Manual key for immediate triggering of the fog emission at 100 % volume. Let the Manual key loose in order to stop
the fog emission.
DMX-512 CONNECTION
If you are using a standard DMX controller, you can connect the DMX-output of the controller directly to the DMX-
input of the first unit in a DMX-chain. Always connect the output of one unit with the input of the next unit until all
units are connected. If you use a controller with 5 pin DMX connection you will need to use a 5-pin to 3-pin adapter.
At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between signal (-) and signal (+)
into a 3-pin XLR connector and plug this into the DMX output of the last fixture in the chain.
Address Setup:
Press the MODE button a number of times until Add appears on the display, with the UP / DOWN buttons the start address may
be set. The start address is defined as a first channel to which the machine will respond to. Check that there are no overlapping
channels used!
CLEANING
After 40 operating hours, the smoke machine must be cleaned to avoid deposits in the machine, pump and heater.
Procedure:
Remove smoke fluid from the tank, fill "Beamz smoke machine cleaner fluid" (item no. 160.670) into empty tank.
1.
2.
Switch the power on and wait until smoke machine is warmed up.
3.
Press on the button of remote control and pump the liquid through the machine.
4.
Perform the above operation until the tank is empty.
5.
Fill the tank with Beamz smoke fluid.
Run clean procedure in a well-ventilated area!
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents