Kenwood NX-210(G) Service Manual page 45

Vhf digital transceiver
Hide thumbs Also See for NX-210(G):
Table of Contents

Advertisement

Test Equipment Required for Alignment
Test Equipment
1. Standard Signal Generator
(SSG)
2. Power Meter
3. Deviation Meter
4. Digital Volt Meter (DVM)
5. Oscilloscope
6. High Sensitivity
Frequency Counter
7. Ammeter
8. AF Volt Meter (AF VM)
9. Audio Generator (AG)
10. Distortion Meter
11. 8 Dummy Load
12. Regulated Power Supply
■ The following parts are required for adjustment
1. Antenna connector adapter
The antenna connector of this transceiver uses an SMA
terminal.
Use an antenna connector adapter [SMA(f) – BNC(f) or
SMA(f) – N(f)] for adjustment. (The adapter is not provided
as an option, so buy a commercially-available one.)
2. Nut wrench
In order to turn the volume nut and the channel selector
nut, use a recommendation tool.
KENWOOD part No.: W05-1123-00
3. Universal connector
Use the interface cable (KPG-36A/36U) for PC tuning or
the lead wire with plug (E30-3287-28) and screw (N08-0535-
08) for panel tuning. Connect the plug to the universal con-
nector of the transceiver and tighten the screw.
The lead wire with plug (E30-3287-28) and screw (N08-
0535-08) terminals are as follows. Numbers are universal
connector terminal numbers.
Caution
1. When connecting the plug to the universal connector of
the transceiver, a short circuit may occur. To prevent this,
be sure to turn the transceiver POWER switch off.
2. Since the RX AF output is a BTL output, there is a DC
component. Isolate this with a capacitor or transformer as
shown in the fi gure.
ADJUSTMENT
Frequency Range
136 to 174MHz
Modulation
Frequency modulation and external modulation
Output
–127dBm/0.1µV to greater than –20dBm/22.4mV
When performing the Frequency adjustment, the following accuracy is necessary.
• 0.003ppm
Use a standard oscillator for adjustments, if necessary.
Input Impedance
50
Operation Frequency
136 to 174MHz
Measurement Capability
Vicinity of 10W
Frequency Range
136 to 174MHz
Measuring Range
10mV to 10V DC
Input Impedance
High input impedance for minimum circuit loading
DC through 30MHz
Frequency Range
10Hz to 1000MHz
Frequency Stability
0.2ppm or less
5A
Frequency Range
50Hz to 10kHz
Voltage Range
1mV to 10V
Frequency Range
50Hz to 5kHz or more
Output
0 to 1V
Capability
3% or less at 1kHz
Input Level
50mV to 10Vrms
Approx. 8, 3W
5V to 10V, approx. 3A
Useful if ammeter equipped
Major Specifi cations
3. Do not connect an instrument between red or black and
GND.
• Universal connector
1 : SSW
3 : SP–
5 : EMC
7 : PTT
9 : OPT
11 : 5V
13 : RXD
NX-210(G)
2 : SP+
4 : MSW
6 : ME
8 : PF
10 : E
12 : TXD
14 : NC
45

Hide quick links:

Advertisement

Table of Contents
loading