G Check of R.V. coil
)LUVW RI DOO PHDVXUH WKH UHVLVWDQFH RI 59 FRLO WR FKHFN LI WKH FRLO LV GHIHFWLYH 5HIHU WR
,Q FDVH &1.$&1.$ LV QRW FRQQHFWHG RU 59 FRLO LV RSHQ YROWDJH LV JHQHUDWHG EHWZHHQ WKH
WHUPLQDO SLQV RI WKH FRQQHFWRU DOWKRXJK DQ\ VLJQDO LV QRW EHLQJ WUDQVPLWWHG WR 59 FRLO
&KHFN LI &1.$&1.$ LV FRQQHFWHG
Unit operates COOL mode even if it is set to HEAT mode.
'LVFRQQHFW FRQQHFWRU EHWZHHQ
WKH FRPSUHVVRU DQG WKH LQWHOOLJHQW
SRZHU PRGXOH
7XUQ 21 WKH SRZHU VXSSO\ DQG VWDUW
KHDWLQJ WHVW UXQ
7(67 581 23(5$7,21 5HIHU WR
)
Unit operates HEAT mode even if it is set to COOL mode.
'LVFRQQHFW FRQQHFWRU EHWZHHQ
WKH FRPSUHVVRU DQG WKH LQWHOOLJHQW
SRZHU PRGXOH
7XUQ 21 WKH SRZHU VXSSO\ DQG VWDUW
FRROLQJ WHVW UXQ
7(67 581 23(5$7,21 5HIHU WR
)
H Check of outdoor fan motor
'LVFRQQHFW WKH FRQQHFWRUV &1
DQG &1 IURP WKH LQYHUWHU 3&
ERDUG &KHFN WKH FRQQHFWLRQ EHWZHHQ
WKH FRQQHFWRU &1 DQG &1
,V WKH UHVLVWDQFH EHWZHHQ HDFK WHU-
PLQDO RI RXWGRRU IDQ PRWRU QRUPDO"
5HIHU WR
No
)L[HG WR HLWKHU RU 9'&
5HSODFH WKH RXWGRRU IDQ PRWRU
OCH530A
,V WKHUH 9$& EHWZHHQ &1
.$&1.$
RQ WKH LQYHUWHU 3& ERDUG PLQXWHV DIWHU
WKH SRZHU VXSSO\ LV WXUQHG 21"
<HV
5HSODFH WKH ZD\ YDOYH
,V WKHUH 9$& EHWZHHQ &1
.$&1.$
RQ WKH LQYHUWHU 3& ERDUG PLQXWHV DIWHU
WKH SRZHU VXSSO\ LV WXUQHG 21"
No
5HSODFH WKH ZD\ YDOYH
<HV
'LVFRQQHFW &1 IURP WKH LQYHUWHU 3& ERDUG DQG WXUQ RQ WKH SRZHU VXS-
SO\
5RWDWH WKH RXWGRRU IDQ PRWRU PDQXDOO\ DQG PHDVXUH WKH YROWDJH RI &1
%HWZHHQ DQG
%HWZHHQ DQG
%HWZHHQ DQG
'RHV WKH YROWDJH EHWZHHQ HDFK WHUPLQDO EHFRPH DQG
No
9'& UHSHDWHGO\"
'RHV WKH RXWGRRU IDQ PRWRU URWDWH VPRRWKO\"
No
and
5HSODFH WKH LQYHUWHU
No
3& ERDUG
and
5HSODFH WKH LQYHUWHU
<HV
3& ERDUG
<HV
<HV
5HSODFH WKH LQYHUWHU 3& ERDUG