30 km/h or on complete stop (depends on the settings of Idle phase. In this phase AntiHiJack follows two different algorithms the safe stop). depending on the availability of Speed control. If the Speed control is TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
Setting the electromechanical hood lock You can install an optional (third-party) hood lock and program the Immobilizer to lock the hood when locking the vehicle, and open it only after enter PIN code. TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
Accelerometer allows starting the engine and locking it if the information about speed in the CAN-bus, and enables extra features vehicle began movement. for vehicles that have information about speed present in the CAN- bus: TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
Turn the ignition on. Analog steering wheel buttons must be programmed within 15 minutes after the interfacing with the vehicle is completed. If 15 minutes have passed, initiate the reset sequence, and perform programming steps again. TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
Sets alarm values for any of 26 functions to Output5. Individual configuration of alarm inputs – any of 5 functions No. 2. Polarity can be configured if any of the 26 functions is assigned can be assigned to each input. to this output. TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
If the vehicle has failed to travel 10 km after installation and Turn the ignition on. factory default PIN code remained unchanged, it is allowed Enter PIN code, wait for confirmation. to use PIN code “2” for identity verification by pressing an integrated button. TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
Page 8
7. Programming algorithm for function 10 – Original buttons. With the brake pedal pressed go to option 10. The Immobilizer will generate 2 successive series of 10 audible signals, and then will emit intermittent audible signals. With the brake TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
In order to assign any of the buttons recognized by the Immobilizer as the Programming button, press the selected button and hold it for at least 5 seconds until a long audible signal is heard. TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
10 km only by the registered user. after installation. using the button and PUK. By installing the Alarm in the same vehicle as it was installed before (if you know the PIN-code). TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
1 А/20 mA black Maximum current through normally open relay is limited by the cross-section (0,35 мм ) of the wire Current consumption: 1 A (pulse) when transferred, up to 20 mA for acceptance TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
Immobilizer units arrangement in the vehicle Use the picture to draw arrangement of alarm units. This can help when trying to find specific units. Keep this sketch out of the reach of third parties. TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
Maximum current consumption in standby mode, mA Maximum current consumption in standby mode, mA 1200 (for PRIZRAK-520)/200 (for PRIZRAK-510) Operating temperature, °С –40 … +85 Storage temperature, °С –40 … +85 Maximum relative air humidity, % TEC-61201-1 Technical Manualе PRIZRAK-510, 520 v7...
Page 16
Producer - TEC electronics Ltd. The product is produced according to TU 4573-009-78025716-12. Certificate of conformityTS RU C-RU.OC13.B.01026. The product conforms to the requirements of the Technical reglament of Custom Union TR TS 018/2011 "Safety of wheeled vehicles"...
Need help?
Do you have a question about the PRIZRAK-510 and is the answer not in the manual?
Questions and answers