9. Click the "Save Script" button to save the revised script(s).
10. Run the test show a couple times and review the log. It should appear similar to figure 2 but
with the latest values not in red. Measured values that are not between the specified minimum
and maximum are shown in red.
11. Click on a value in the log. A graph of the measured values (similar to figure 3 but with fewer
values) should appear. If the test script has only run once, no graph will appear. At least two
measurements are required to draw the graph.

Script Test Run

The script test run buttons located on the Command Script Definition page allow the user to manually
trigger LSS-100P Command Scripts without having to run the corresponding DCP show normally used.
This may be useful when testing the "post to server" commands. Note that the LSS-100P home page
shows the number of the currently running script (or "none" if one is not running).

Data Analysis

The LSS-100P presents the captured data in a log (as shown in figure 2) and a graph (as shown in figure
3). Out of limit operation is easily identified in the log by a value being printed in red. The graphs show
the measured values along with limit lines allowing easy detection of trends and out of limit operation.
Ethernet Device Discoverer
also be used to show out of tolerance operation within a theater.
v160817
LSS−100P Installation & Operation Manual
Figure 11 - LSS-100P Command Script Page