Operation near (e . g . 1 m from) a short wave or microwave device may cause fluctuations in the baseline values of the electrotherapy device . The minimum area of the electrodes should not be less than 2 cm Operating Instructions EMP 4 Expert...
The maximum output parameters of the product follow this symbol . The product contains a NiMH accumulator . This accumulator ist reusable . Please observe the regulations for reuse . NiMH Conform with Council Directive 93/42/EEC of 14 June 1993 concerning medical devices . 0197 Operating Instructions EMP 4 Expert...
. 175 mm x 90 mm x 30 mm Weight approx . 280 g without accessories Pulse forms Biphasic, symmetrical with 1kΩ load real with ANSI 00 without pause with output short circuit control element Biphasic, asymmetrical with 1kΩ load real with ANSI 00 with output short circuit control element Biphasic, symmetrical with 1kΩ load real with ANSI 00 with pause without output short circuit control element Change in output current depending on load Operating Instructions EMP 4 Expert...
Use the 4 key to display current settings and to change them if necessary . 6.4 Starting stimulation Start stimulation by pressing the key . Use the modifica- tion keys to set intensity to a pleasant value . Operating Instructions EMP 4 Expert...
Page 7
. 6. Switching off the device Pressing the on/off key will switch off the device . The EMP 4 Expert will switch itself off when no key is pressed for 3 minutes or when stimulation is not started . Operating Instructions EMP 4 Expert...
Intensity modulation in channels 1 and 2 Continuous modulation in channels 3 and 4 Agonist/Antagonist Standard stimulation All 4 channels work simultaneously Agonist/Antagonist stimulation Channels 1 and 2 switch with channels 3 and 4 Timer (0 = no treatment time) Operating Instructions EMP 4 Expert...
Page 9
The parameters indicated here apply to channels 3 and 4 only . The values could be changed by using the modification keys . Pulse form channels 3 and 4 Pulse width channels 3 and 4 Frequency channels 3 and 4 Operating Instructions EMP 4 Expert...
Page 10
. Use the key to check set parameters and to change them if necessary . Use the key to interrupt stimulation (pause) . .1. Stimulation icons Standard stimulation Intensity modulation: Pause Intensity modulation: Ramp Intensity modulation: Work Operating Instructions EMP 4 Expert...
Page 11
P Q R S T U V W X Y Z [ / ] ^ _ ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ SPACE Operating Instructions EMP 4 Expert...
Page 12
The on/off key switches off the appliance and stops stimulation . .1.11 Switching off the appliance Pressing the on/off key will switch off the device . The EMP 4 Expert will switch itself off when no key is pressed for 3 minutes or when stimulation is not started . Operating Instructions EMP 4 Expert...
. Increasing ramp Work Decreasing ramp GENERAL General parameter The parameters indicated here apply to all 4 channels . The values could be changed by using the modification keys . Pause Number of stimulation cycles Operating Instructions EMP 4 Expert...
Page 14
(ramps), can be set with the modification keys to a pleasant value . The flashing dot marks this setting mode . Use the key to stop stimulation . Use the key to increase intensity of all 4 channels simul- taneously . Operating Instructions EMP 4 Expert...
Page 15
. Use the key to stop stimulation . .. Stimulation icons Standard stimulation Intensity modulation: Pause Intensity modulation: Ramp Intensity modulation: Work Operating Instructions EMP 4 Expert...
Page 18
. The flashing circles identify this stimulation . identifies the time left of the current sequence and the entire programme . also identifies the current sequence . Operating Instructions EMP 4 Expert...
Page 19
Stimulation is stopped during the stimulation pause . No pulses are STRENGTH generated . Use the key to stop stimulation . Use the key to switch to the sequence alteration screen . Use the key to continue stimulation with a 1 second ramp . Operating Instructions EMP 4 Expert...
Page 20
The on/off key switches off the appliance and stops stimulation . ..14 Switching off the appliance Pressing the on/off key will switch off the device . The EMP 4 Expert will switch itself off when no key is pressed for 3 minutes or when stimulation is not started . Operating Instructions EMP 4 Expert...
. It may only be used to charge the WA 60- batteries supplied with the device using the AL 1 A charging station . The plug-in battery charger and the batteries must not be short-circuited . Operating Instructions EMP 4 Expert...
1 . Checking to see whether the user instructions and the medical device book are included in the accompanying documentation . 2 . Checking the equipment for completeness . 3 . Visual check: - for mechanical damage - for damage to all cables and connections Operating Instructions EMP 4 Expert...
1 Pack self adhering electrodes REF 283400 50 mm x 50 mm (Packing Unit = 4 electrodes) 2 Packs self adhering electrodes REF 283600 50 mm x 90 mm (Packing Unit = 2 electrodes) 1 Transport box REF 450980-0039 Operating Instructions EMP 4 Expert...
Stimex, round 32 mm Ø 4 pc . 282000 Stimex, round 50 mm Ø 4 pc . 283300 Stimex, 50 x 30 mm 4 pc . 283400 Stimex, 50 x 50 mm 4 pc . Operating Instructions EMP 4 Expert...
Page 25
Electrode cable type 5 .17, red 1 pc . 106354 Electrode cable type 5 .18, yellow 1 pc . 104704 Charger P 60-8 1 pc . 104709 Charging station AL 1 A 1 pc . Operating Instructions EMP 4 Expert...
Page 26
Art. No. Description Quantity 104706 Rechargeable battery WA 60-8 (NiMH) 1 pc . Operating Instructions EMP 4 Expert...