WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An unvented
room he osphere experienced during cold weather.
Unvented room heaters are recommended as supplemental heat (a
room) rather than a primary heat source (an entire house). In most
supplemental heat applications, the water vapor does not create a
problem. In most applications, the water vapor enhances the low
humidity atmosphere experienced during cold weather.
PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR
This heater shall not be installed in a confined space or unusually
tight construction unless provisions are provided for adequate com-
bustion and ventilation air.
The National Fuel Gas Code defines a confined space as a space
whose volume is less than 50 cubic feet per 1,000 Btu per hour
3
(4.8m
per kw) of the aggregate input rating of all appliances in-
stalled in that space and an unconfined space as a space whose
volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8
3
m
per kw) of the aggregate input rating of all appliances installed
in that space. Rooms communicating directly with the space in
which the appliances are installed, through openings not furnished
with doors, are considered a part of the unconfined space.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough
fresh air for combustion and ventilation. However, in buildings of
unusually tight construction, you must provide additional fresh
air.
Unusually tight construction is defined as construction
where:
a. Walls and ceilings exposed to the outside atmosphere have
a continuous water vapor retarder with a rating of one perm
or less with openings gasketed or sealed, and
b. Weatherstripping has been added on openable windows
and doors, and
c. Caulking or sealants are applied to areas such as joints
around window and door frames, between sole plates and
Page 6

SPECIFICATIONS

VFHS-20/10T
20,000/10,000
7,000/7,000
26 1/2"
11"
11"
22 3/4"
17 1/4"
3/8"
3/8"
Accessories For VFHS-20R Only
FRBC-1
Battery Operated Remote Control
FRBTC-1
Battery Operated Remote Control
w/Thermostat
FREC-1
Electric Remote Control
FWS-1
Wall Switch
GWSG-T
Wall Thermostat, Millivolt
Mantel Accessories
EHM24-U
Mantel - Unfinished
EHM24-OF
Mantel - Oak
EHM24-CU
Corner Mantel - Unfinished
EHM24-COF
Corner Mantel - Oak
The following steps will help insure that water vapor does not
become a problem.
1. Be sure the heater is sized properly for the application, including
ample combustion air and circulation air.
2. If high humidity is experienced, a dehumidifier may be used to
help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary heat source.
floors, between wall-ceiling joints, between wall panels, at
penetrations for plumbing, electrical, and gas lines, and at
other openings.
If your home meets all of the three criteria above, you must
provide additional fresh air. See "Ventilation Air From
Outdoors," page 7.
Determining if You Have a Confined or Unconfined Space
Use this worksheet to determine if you have a confined or
unconfined space.
Space: Includes the room in which you will install heater plus any
adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height =
of space)
Example: Space size 16 ft. (length) x 10 ft. (width) x 8 ft.
(ceiling height) = 1,280 cu. ft. (volume of space)
If additional ventilation to adjoining room is supplied with
grills or openings, add the volume of these rooms to the total
volume of the space.
2. Divide the space volume by 50 cubic feet to determine the
maximum BTU/Hr the space can support.
(volume of space) ÷ 50 cu. ft. = (maximum
BTU/Hr the space can support)
Example: 1,280 cu. ft. (volume of space) ÷ 50 cu. ft. = 25.6 or
25,600 (maximum BTU/Hr the space can support)