Optional Blower Installation Instructions - Empire Comfort Systems VFHS-20R-1 Installation Instructions Manual

Unvented gas fireplace
Table of Contents

Advertisement

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

VFS-BK for Unvented Gas Fireplace Model VFHS-20/10T, VFHS-20R
INSTALLING OPTIONAL BLOWER VFS-BK
1. Lower bottom louver.
2. Remove screen front by lifting upward on screen front.
3. Remove top louver [(2) 8 x 1/2" Phillips screws].
4. Remove rear log support from inner casing [three (3) 10
x 1/2" screws.] (See Figure 1)
5. Remove three (3) 10 x 1/2" screws that attach burner
assembly to inner bottom. (See Figure 1)
6. Remove six (6) 10 x 1/2" screws that attach inner casing to
outer casing. Loosen two (2) 10 x 1/2" screws at interior, top
of inner casing. Remove inner casing from outer casing by
pivoting left side of inner casing. (See Figure 1)
7. For fireplace that is not installed, remove burner assembly
from interior of fireplace.
7. For fireplace that is installed, burner assembly will remain
with fireplace.
8. Insert blower assembly into left side of outer casing. Motor
with wiring will be to inside of outer casing, blower chute
will be facing upward. (See Figure 2)
9. Place and align two (2) orange motor mounting gaskets at
rear of motor mounting brackets. Start two (2) 8 x 1/2"
Phillips screws into motor mounting brackets and gaskets on
side opposite motor. Start one (1) 8 x 1/2" Phillips screw into
top motor mounting bracket and gasket adjacent to motor.
Align and attach blower assembly to outer casing side. (See
Figure 2)
10. Snap Heyco into blower shield side.
11. Place blower shield side adjacent to motor. Route blower
motor wires through Heyco on blower shield side. (See
Figure 3 and Figure 4)
VFHS-20/10
Figure 1
12. Attach black wire from wire harness to ON terminal on
AUTO/OFF/ON switch.
13. Attach white/black wire from wire harness to OFF terminal
on AUTO/OFF/ON switch.
14. Attach black/red wire from wire harness to AUTO terminal
on AUTO/OFF/ON switch.
Figure 2
15. Route two (2) flag terminals on wire harness through Heyco
on blower shield side.
16. Attach two (2) flag terminals on wire harness to fan control
(bracket).
17. Route cord set wires through access hole on right side of
outer casing.
18. Insert strain relief in access hole on right side of outer casing.
19. Attach plastic terminals on wiring harness into plastic
terminals on cord set.
20. Attach green ground wires from wiring harness and cord set
to interior back of outer casing with one (1) 8 x 1/2" Phillips
screw.
21. Position blower shield side beneath left flange on burner
Page 23