Maintenance
LAMP CHECKOUT (Does not illuminate.)
1. Check power cord for 120V power.
2. Unplug power cord and remove access door.
3. Slide out assembly and remove pleated filter or
metal insert.
4. Check lamps for proper connection in sockets.
5. Exchange non-working lamp with one of the
working lamps. If the new lamp operates nor-
mally, replace defective lamp.
6. If steps 1 through 5 pass inspection then the ballast
may be at fault. Ballast must be replaced with an
approved ballast by a qualified service technician.
LAMP DISPOSAL
Hg-LAMP CONTAINS MERCURY.
Manage in accord with disposal laws.
Refer to www.lamprecycle.org or call 1-800-9-LENNOX.
CAUTION
Lamps contain Mercury.
Ingestion or contact with mercury or mercury vapor
is hazardous to your health.
Take care when handling lamps. If lamp breaks,
avoid contact with mercury.
Model PCO-12C Exploded View
Replacement Parts
No.
Description
Complete PureAir™ System
1
Cabinet
2
Assembly
3
Access Door
4
Electrical Socket
5
UVA Lamp
6
Lamp Socket
7
Ballast
8
Titanium dioxide coated metal insert
9
MERV 9 pleated filter
Power Cord (Not Shown)
Contact your local Lennox dealer to order replacement parts.
For the Lennox dealer nearest you, dial 1-800-9-LENNOX.
Visit us at http://www.Lennox.com
PROPER CLEAN-UP TECHNIQUE IN CASE OF
LAMP BREAKAGE
●
Wear protective gloves, eyewear and mask.
●
Sweep the broken glass and debris into a plastic bag,
seal the bag, and dispose of properly. Contact your
local waste management office for proper disposal.
●
Do not use a vacuum cleaner. Do not incinerate
Model PCO-20C Exploded View
1
2
3
4
5
6
7
8
9
7
PCO-12C-2 PCO-20C-2
75X69
75X61
75X72
75X65
75X70
75X62
93X39
75X64
75X77
75X77
10M35(4)
10M35(6)
49M00
49M00
56M12
56M12
75X73
75X66
75X74
75X67
49M48
49M48
.
Need help?
Do you have a question about the PureAir PCO-12C-2 and is the answer not in the manual?