INSTALLATION INSTRUCTIONS FOR LENNOX MODELS EAC-14-2, EAC-16-2 AND EAC-20-2
Introduction
Please read instructions before installing and using the Elec-
tronic Air Cleaner. This will help you obtain the full benefit from
the Electronic Air Cleaner you have selected. It will also help
you avoid needless service costs that result from causes we
cannot control and cannot cover in our guarantee.
L
!
ELECTROCUTION HAZARD
Shut off power at fuse panel before
servicing. Failure to do so could result
in serious personal injury or death.
L
WARNING
!
Do not attempt installation of this unit unless you are
familiar with the necessary tools, equipment, utility
connections and potential hazards.
Installation should be performed only by a qualified
service provider.
Failure to do so could result in reduced performance
of the unit, serious personal injury or death.
Shipping and Packing List
Package 1 of 1 contains:
1 - EAC Cabinet
2 - Cells
1 - Power Pack
2 - Pre-Filters
1 - Wash Reminder Label
1 - High Voltage Warning Label
1 - Installation Instructions
1 - IAQ Guide and Warranty
Electronic Air Cleaner Models
EAC-14 (90N80) is designed for application with air
handlers which deliver air volumes up to 1600 cfm.
EAC-16 (X1187) is designed for application with air
handlers which deliver air volumes up to 2000 cfm.
EAC-20 (90N81) is designed for application with air
handlers which deliver air volumes up to 2200 cfm.
AIR CLEANERS/
®
FILTERS
504,812M
06/03
WARNING
HEALTHY CLIMATE
ELECTRONIC AIR CLEANER
Rules for Safe Installation and Operation
1. Read this manual carefully. Failure to follow these rules
and instructions could cause a malfunction of air cleaner
or unsatisfactory service and could void your warranty.
2. Follow a regular service and maintenance schedule
to ensure efficient operation.
3. Unit must run for one full hour after installation to allow
the collecting cells to reach peak efficiency.
L
WARNING
!
Installation of this unit must comply with local
electric codes or other applicable codes.
Review and understand local codes prior to
installation.
L
WARNING
!
Persons with respiratory illness or conditions
should consult their physician prior to installing an
electronic air cleaner.
L
WARNING
!
Sparks which occur during air cleaner operation
may become a source of ignition.
Fire or explosion may occur if flammable vapor or
other combustible products are present while air
cleaner is operating.
Do not operate air cleaner when flammable vapor
or other combustible products are present.
L
CAUTION
!
CABINET
MAY
CONTAIN
Use care when servicing unit. Failure to do so could
result in personal injury.

Required Tools

• Tin Snip
• Screwdriver
• Rule or Tape Measure
• Drill
Lennox Industries, Inc.
Dallas, Texas
1-800-9-LENNOX
www.lennox.com
®
SHARP
EDGES.
PART NO. 37-6128D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EAC-14-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lennox EAC-14-2

  • Page 1: Required Tools

    Dallas, Texas USA 504,812M 06/03 ELECTRONIC AIR CLEANER INSTALLATION INSTRUCTIONS FOR LENNOX MODELS EAC-14-2, EAC-16-2 AND EAC-20-2 Introduction Rules for Safe Installation and Operation Please read instructions before installing and using the Elec- 1. Read this manual carefully. Failure to follow these rules tronic Air Cleaner.
  • Page 2: Table Of Contents

    ➁ black soiling contaminants (dirt and Odors are gas molecules, not particles. For best odor smoke particles). removal options, ask your Lennox dealer about other Healthy Climate products, such as the PureAir The residue on the collecting plates of an electronic air purification system.
  • Page 3: Parts Identification

    Parts Identification Its basic components, and their functions, are as follows: (See Figure 2) Cabinet - mounts to existing duct and houses the collecting cells and pre-filters. Pre-Filters Handle Cabinet Collecting Cells - two separate cells are included. Each cell includes ionizing wires which charge the particles and collecting plates which collect the ionized dust, dirt and other impurities from the air.
  • Page 4: Preinstallation

    Preinstallation Not to Exceed 20˚ (Interchangeable) (Interchangeable) Air Flow Collecting Cell Collecting Cell Outlet Box Cabinet Power Pack Handle Air Flow Furnace Opening Electronic Air Cleaner Contact Opening Button Contact Furnace Electronic Pre-Filters Button Transition Section Air Cleaner (Interchangeable) See text for Cell (if Needed) Removal Clearance Figure 4...
  • Page 5 TYPICAL APPLICATIONS Air Flow Air Flow Air Flow Rear View Rear View Figure 6 Figure 8 Figure 7 BASEMENT FURNACE UPFLOW FURNACE (LOWBOY) (Figure 6) (Figure 8) DOWNFLOW FURNACE (Figure 7) Cleaner is mounted hori- Side installation. Cleaner zontally in return plenum, is mounted vertically, Cleaner is mounted horizon- just above furnace.
  • Page 6: Installation

    Installation WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, per- sonal injury or loss of life. Installation and service must be performed by a qualified installer or service agency. REMOVE OLD FILTER AND DISCARD (Figure 12) Figure 12 NOTE - The existing filter may be installed inside the air handler cabinet.
  • Page 7: Wiring Instructions

    Wiring Instructions 7. With the cabinet installed, the air cleaner can now be 10. With the cabinet Installed, reinstall pre-filter(s) and collecting cell(s) (Figure 19). wired to electrical input source. NOTE: The contact button and handles on the cell WARNING must be facing you and ionizing wires must be on the air intake side.
  • Page 8: Operation

    Operation 1. Make sure 120VAC power is turned on at the circuit breaker which serves the air handler. Slide the air cleaner switch into the “ON” position (Figure 20). 2. The air cleaner should operate when the indoor blower is on. You may hear an occasional arcing or snapping sound.
  • Page 9: Specifications

    Specifications AIR CLEANER MODEL NUMBER SPECIFICATIONS EAC-14 EAC-16 EAC-20 Rated Capacity 1400 cfm 1600 cfm 2000 cfm Max. Pressure Drop .08 in. W.G. .12 in. W.G. .09 in. W.G. Cell Weight (2) 9 lbs. each (2) 9 lbs. each (2) 11 lbs. each Power Pack Weight 8 lbs.
  • Page 10: Basic Service Guide

    Basic Service Guide This guide covers most homeowner complaints. If, after checking the items listed, the unit still fails to operate properly, contact your Lennox dealer. SYMPTOM POSSIBLE CAUSE ON/OFF switch “ON” Unit functioning normally. Blower ON Operating Light ON ON/OFF switch “ON”...
  • Page 11: Service

    Service All voltage measurements indicated can be made with a WARNING high voltage D.C. probe and a general purpose volt ohm Do not attempt repair of this unit unless you are meter. For example: Simpson 260 or equivalent. familiar with the necessary tools, equipment, For test purposes, the air flow switch may be “wired out”...
  • Page 12 POWER SUPPLY CHECK OUT PROCEDURE AIR FLOW MONITOR TEST 1. Connect a multimeter set to read 120 VAC to power 1. Turn power switch to the “OFF” position and remove supply terminals marked “LINE.” the power pack from cabinet. 2. Connect 120 VAC to power pack plug, turn power 2.
  • Page 13: Healthy Climate ® Electronic Air Cleaner Upgrade Kit

    OZONE REDUCTION Ozone Reduction Jumper OZONE WARNING Figure 24 All electronic air cleaners produce a small amount of ozone. Some individuals are sensitive to ozone and Cut and separate may notice an odor or may experience a physiological Ozone Reduction response (including lung irritation), especially at high Jumper altitudes or low airflow rates.
  • Page 14 Replacement Parts...
  • Page 15 • 69H98 • X1194 • 72H09 Air Flow Switch (w/Mtg.Hdwr) 80K61 80K61 80K61 • Two (2) Required † Not Shown Contact your local Lennox dealer to order replacement parts. For the Lennox dealer nearest you, dial 1-800-9-LENNOX, or visit www.lennox.com.
  • Page 17 Dallas, Texas USA 504,812M 06/03 ® HEALTHY CLIMATE INSTRUCTIONS D’INSTALLATION, MODÈLES LENNOX EAC-14-2, EAC-16-2 ET EAC-20-2 Introduction Installation et exploitation sécuritaires Veuillez lire les directives avant d’installer et d’utiliser l’épurateur Lire attentivement le présent guide. Si ses directives n’étaient pas électronique, ce qui vous permettra de profiter pleinement des avan-...
  • Page 18 Pour connaître le meilleur moyen d’éliminer les odeurs, les irritants et les contaminants mentionnés plus haut, soit parce consulter le détaillant Lennox à propos des autres produits Healthy qu’elles se sont déposées avant d’avoir pu atteindre le filtre. La Climate, comme l’équipement de purification de l’air PureAir...
  • Page 19: Identification Des Pièces

    Identification des pièces Voici une brève description des principaux composants de l’appareil et de leurs fonctions (voir la figure 2). Le boîtier : Installé dans les conduits existants, il renferme les cellules et les préfiltres. Les cellules collectrices : Deux cellules sont incluses. Chacune comporte des fils ionisants, qui donnent une charge électri- que aux particules, et des plaques collectrices, qui captent la poussière, la saleté...
  • Page 20: Installation Préliminaire

    Installation préliminaire Ne pas d passer 20° C llul c ll c c C llul c ll c c Écoulement chang abl ) chang abl ) de l’air Écoulement de l’air u erture du n rateur u erture de l’ purateur lectroni ue c n ac n rateur...
  • Page 21 POSITIONS DE MONTAGE TYPIQUES Écoulement de l’air Écoulement de l’air Écoulement de l’air ue de l’arri re ue de l’arri re i ure i ure i ure GÉNÉRATEUR DE SOUS- GÉNÉRATEUR À CAISSONS SOL (À CAISSONS JUXTA- SUPERPOSÉS (figure 8) GÉNÉRATEUR À...
  • Page 22: Installation

    Installation MISE EN GARDE Des dommages matériels ainsi que des blessures ou même la perte de vies peuvent survenir si l’appareil est installé, ajusté, modifié, révisé ou entretenu incorrectement. Toute installa- tion ou révision doit être laissée aux soins d’un installateur ou d’une entreprise disposant des qualifications requises.
  • Page 23: Câblage

    Câblage Une fois le boîtier installé, on peut raccorder l’épurateur sur le 10. Une fois le boîtier installé, y introduire les préfiltres et les circuit d’alimentation électrique. cellules (figure 19). REMARQUE : Le bouton de contact et les poignées des cellules MISE EN GARDE doivent être orientés vers soi et les fils ionisants doivent être orientés vers l’entrée d’air.
  • Page 24: Exploitation

    Exploitation S’assurer que le générateur d’air est alimenté en courant de 120 V c.a. Glisser l’interrupteur à la position de marche (figure 20). L’épurateur devrait fonctionner lorsque le ventilateur intérieur est en marche. Un claquement peut parfois se faire entendre. Il survient lorsqu’une grosse particule de saleté...
  • Page 25: Fiche Technique

    Fiche technique E E ’ P CA ACT EAC 14 EAC 16 EAC 20 Capacité nominale 1400 pi /min 1600 pi /min 2000 pi /min Chute de pression maxi. 0,08 po C.E. 0,12 po C.E. 0,09 po C.E. Poids des cellules 2 x 4,1 kg (9 lb) chacune 2 x 4,1 kg (9 lb) chacune 2 x 5,0 kg (11 lb) chacune Poids, module d’alim.
  • Page 26: Guide De Révision De Base

    Guide de révision de base Ce guide répond à la plupart des questions des propriétaires. Si l’appareil continue de faire défaut après vérification des points figurant ci- dessous, communiquer avec le détaillant Lennox. SYMPTÔME CAUSE POSSIBLE Interrupteur en position de L’appareil fonctionne correctement.
  • Page 27: Révision

    Révision Toutes les mesures de tension peuvent être effectuées à l’aide d’une MISE EN GARDE sonde C.C. à haute tension et d’un multimètre, comme par exemple un appareil Simpson 260 ou l’équivalent. Ne pas tenter de réparer l’appareil avant de s’être complète- Pour vérifier le module d’alimentation, on peut mettre le détecteur de ment familiarisé...
  • Page 28 PROCÉDURE DE RÉVISION DU BLOC ESSAI DU DÉTECTEUR DE DÉBIT D’AIR D’ALIMENTATION Brancher un multimètre réglé pour une lecture de 120 V C.A. sur les bornes « LINE » du bloc d’alimentation. Mettre l’interrupteur à la position d’arrêt (OFF) et détacher le Alimenter la fiche du module d’alimentation en courant de 120 V module d’alimentation du boîtier.
  • Page 29: Ensemble D'épurateur D'air Électronique Healthy Climate Pour Mise À Niveau

    RÉDUCTION DE L’OZONE MISE EN GARDE CONCERNANT L’OZONE Tous les épurateurs d’air électroniques dégagent une petite quantité d’ozone. Certaines personnes sensibles à l’ozone peuvent détecter une odeur ou avoir une réaction physiologi- que (irritation pulmonaire, par exemple), tout particulièrement à haute altitude ou lorsque le débit d’air est faible. Dans de tels cas, il y a deux méthodes possibles pour réduire la concentra- tion d’ozone : Couper et séparer le...
  • Page 30: Pièces De Rechange

    Pièces de rechange...
  • Page 31 • 72H09 Détecteur de débit d’air (+pcs montage) 80K61 80K61 80K61 • Deu (2) pi ces requises † Élément non illustré Commandez les pièces de rechange auprès de votre détaillant Lennox. Pour connaître votre détaillant Lennox, composez 1-800-9-LENNOX ou visitez www.lennox.com.

This manual is also suitable for:

Eac-16-2Eac-20-2

Table of Contents

Save PDF