A-4
Supplemental Drive Information
Category
Specification
Electrical
Voltage Tolerance:
Frequency Tolerance:
Input Phases:
Displacement Power Factor:
Efficiency:
Maximum Short Circuit Rating:
Actual Short Circuit Rating:
Transistor Type:
Internal DC Bus Choke:
200-240V AC Input:
380-480V AC Input:
Control
Method:
Carrier Frequency
Frames C and D:
Frames E and F:
Frequency Accuracy
Digital Input:
Analog Input:
Analog Output:
Speed Regulation - Open Loop with Slip
Compensation:
Output Frequency:
Stop Modes:
Accel/Decel:
Intermittent Overload:
Electronic Motor Overload Protection
Control Inputs
Digital:
Analog:
Quantity:
Type
Source Mode (SRC):
Sink Mode (SNK):
Quantity:
Specification
Resolution:
0 to 10V DC Analog:
4-20mA Analog:
External Pot:
200-240V ±10%
380-480V ±10%
48-63 Hz
Three-phase input provides full rating. Single-phase
operation provides 50% rated current.
0.98 across entire speed range
97.5% at rated amps, nominal line voltage
100,000 Amps Symmetrical (Frame C Drives)
200,000 Amps Symmetrical (Frame D, E, F Drives)
Determined by AIC Rating of installed fuse/circuit
breaker
Isolated Gate Bipolar (IGBT)
11-37 kW (15-50 HP) Panel Mount Drives
11-110 kW (15-150 HP) Panel Mount Drives
Sinusoidal PWM, Volts/Hertz
2-10 kHz, Drive rating based on 4 kHz
2-8 kHz, Drive rating based on 4 kHz
Within ±0.05% of set output frequency
Within 0.5% of maximum output frequency, 10-Bit
resolution
±2% of full scale, 10-Bit resolution
±1% of base speed across a 60:1 speed range
0-320 Hz (programmable)
Multiple programmable stop modes including - Ramp,
Coast, DC-Brake, Ramp-to-Hold and S Curve.
Two independently programmable accel and decel
times. Each time may be programmed from 0 - 600
seconds in 0.1 second increments.
110% Overload capability for up to 1 minute
Class 10 protection with speed sensitive response.
(3) Semi-programmable
(4) Programmable
18-24V = ON, 0-6V = OFF
0-6V = ON, 18-24V = OFF
(1) Isolated, –10 to 10V or 4-20mA
(1) Non-isolated, 0 to 10V or 4-20mA
10-bit
100k ohm input impedance
250 ohm input impedance
1-10k ohm, 2 Watt minimum

Hide quick links: