Specifications - Onkyo A-8150 Service Manual

Hide thumbs Also See for A-8150:
Table of Contents

Advertisement

A-8150
SPECIFICA TIONS
Power Output:
Total Harmonic Distortion
I M Distortion
Damping Factor:
Frequency and Response:
Sensitivity and Impedance
Phono Overload:
Bass Control:
Treble Control:
Signal to Noise Ratio:
Loudness Control:
Muting:
Selective Tone Control
General
Power Supply:
Dimensions (W x H x D):
Weight:
PRECAUTIONS
60 watts per channel, min, RMS, at
8 ohms, both channels driven from
20 Hz to 20 kHz, with no more than
0.06% THO.
0.06% at 60 watts
0.06% at 60 watts
40 at 8 ohms
15 -30,000
Hz ± 1 dB
Phono (MM):
2.5 mV/50 kohms
Phono (MC):
350 ~V/330 ohms
Tuner/CD/AUX:
!.§Q...wV/50 kohms
Tape/Play:
~V/50
kohms
Tape/Rec:
~V/4.5
kohms (phono)
150 mV RMS at 1 kHz, 0.06% THO (MM)
± 10 dB at 100 Hz
±10 dB at 10,000 Hz
Phono: 83 dB (IHF A), 5 mV input
CD
&
Tape:
95 dB (IHF A)
+7 dB at 70 Hz/+5 dB at 10 kHz
-20 dB
±15 dB at 50
Hz/±6
dB at 10kHz
European models:
AC220V, 50Hz
Canadian models:
AC120V, 60Hz
British & Australian models:
AC240V, 50Hz
Worldwide models: AC120V and 220V
switchable, 50/60
Hz
435 x 110 x 272 mm
17-1/8"
x 4-5/16"
x 10-11/16"
7.0 kg, 15.4 Ibs.
1. Replacing the fuses
For continued protection against risk fire, replace only with same type and same rating fuse.
CIRCUIT NO.
F901
F902
PART NO.
252050
252075 or
252075CC
252078 or
252078CC
F911,F912
DESCRIPTION
5A(ST-6), Primary fuse 020V model)
2.5A-SE·EAK Primary fuse (220V, 240V, 120V/220V model)
2.5A-SE-EAK Primary fuse (220V, 240V, 120V/220V model)
5A-SE-EAK, Secondary fuse (220V, 240V model)
5A-SE-EAK, Secondary fuse (220V, 240V model)
2. Insulation resistance mesurement (Only U.S.A. model)
Connect the insulating-resistance tester between the plug of power supply cable and the terminal GND on the back panel.
Specifications; More than 10 MD at 500V.
3. Voltage selector (rear panel)
Worldwide models are equipped with a voltage selector to conform with local power supplies. Be sure to set this switch
to match the voltage of the power supply in your area before turning the power switch on. Voltage is changed by sliding
the groove in the switch with a screwdriver or similar instrument to the right or left position. Confirm that the switch has
been moved all the way to the right or left before turning the power switch on. If there is no voltage selector switch
on the unit you have purchased, it can only be used in areas where the power supply voltage is the same as that of the
unit.
220V~
120V~
120V~
220V~
at AC 120V
at AC 220V
-2-

Hide quick links:

Advertisement

Table of Contents
loading