1 – Power Button – On/Off and activating rotary beams
2 – Button for slope and clockwise beam rotation in scanning mode
3 – Button for slope and counterclockwise beam rotation in scanning
mode
4 – Button for manual or automatic mode
5 – Button for detector mode
Counterclock-
wise rotation
Arrow down (3)
Manual
mode (4)
Usage
1) Press once the power button (1), to switch the instrument on. The
MODE LED fl ashes green. The horizontal line is activated. After leveling
the MODE LED is permanently green and the rotation starts. If the in-
strument is not able to level, the red LED fl ashes quickly. Re-position the
rotary laser in a more horizontal way. Pressing the power button again
activates the additional lines (according to model H/V/HV/HVV).
2) Press the button (4) once to switch to the manual mode. The red
ALARM LED is on. By pressing the button (4) again, the instrument goes
back to the automatic mode.
3) In manual mode press the buttons (2) and (3) to slope the laser re-
ference. (2) inclines the X axis upwards. (3) inclindes the X axis down-
wards.
4) Press the button (5) several times to change the rotation speed
(800/400 and 2000 rotations per minute). For usage with a laser de-
tector, please select 800 or 2000. Press the button (5) long to switch
to the scanning mode. This function is only available for the horizontal
beam. You can rotate the scanner beam with the buttons (2) and (3) .
MODE
Buttons and LEDs
ALARM
SPEED
On-/Off (1)
Clockwise
rotation
Arrow up (2)
Scanning/
Rotation
speed(5)