10.2 Controller input • Output Measurement
・ Re-confirm the following output level and resistance at the time of controller replacement.
・ Measure output level by tester while switching a load part
・ Value mentioned below may be changed depend on power supply voltage or an error of the tester.
・ For the motor measurement, apply 3 combinations of [red - blue] [red - purple] [blue - purple]
to confirm normal value.
・ Value of the push switch measurement is 220~240V without pushing power button and 0V to push the button once.
Warning
Beware of electric
shock at a lead wire
of charge unit during
Beware
of Electric
measurement.
Shock
※ ( ) is a color of the connectors
※ Disconnect connectors for measuring resistance