DTT Series Digital Torque Testers
User Manual
for DTT Models above Serial Number: 2000
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
44110-3898
Phone: (
| Fax: (
888) 486-6163
216) 481-4519
© 2017 Jergens, Inc. All Rights Reserved | Revision Date: 04/10/17
Page 1 of 23
Email: asginfo@asg-jergens.com | Web: www.asg-jergens.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DTT-5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ASG DTT-5

  • Page 1 DTT Series Digital Torque Testers User Manual for DTT Models above Serial Number: 2000 ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH 15700 44110-3898 Phone: ( | Fax: ( 888) 486-6163 216) 481-4519 © 2017 Jergens, Inc. All Rights Reserved | Revision Date: 04/10/17 Page 1 of 23 Email: asginfo@asg-jergens.com | Web: www.asg-jergens.com...
  • Page 2: Table Of Contents

    Memory ......................15 View ......................15 Delete Last ....................16 Delete All ...................... 16 Upload All ..................... 16 ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 3 Pass/Fail ......................21 Retrieving Information from the DTT............. 22 Capturing Data in Real Time ................. 23 Error ......................23 ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 4: Service And Warranty

    ASG, Division of Jergens, Inc., warrants to the original purchaser buying the ASG DTT meter with the intention of use rather than resale, for a period of 1 year. ASG will replace those items found to be defective or otherwise fail to conform, or at ASG’s option repay the price paid for the item.
  • Page 5: Battery Charger

    Graphics LCD Display Size 128x64 dots Battery 17 hour battery life (NiMH 7.2/v Rechargeable) Battery Charger 110-120 VAC 60 Hz 12W input, 12 VDC 500ma output (Optional International Charger Available: 220-240 VAC input, ASG # 915966) 16 Bit 8 Bit Communication...
  • Page 6: Standard Equipment

    All DTT meters are supplied with the following standard items: • DTT torque meter • Battery charger • Mini USB to USB cable (ASG #66629) • Rundown adapter (see chart below) • Carrying case with insert ASG #CP66614 and Included with DTT-5 (66700)
  • Page 7: Instructions For Using The Rundown Adapter

    5.65 - 22.6 66642 3/8" Hex 50.0 - 500.0 5.65 - 56.5 * ASG Adapter #66612 comes with two springs covering torque range from 1.3-5.0 lbf.in (0.15-0.56) and 4.5-26.0 lbf.in (0.51-2.94 N.m) ASG #66620 ASG #66631 ASG #66612 ASG #66617...
  • Page 8: Usage

    The proper reading may be an average of several readings. • Always unwind the rundown adapter after each test. Do NOT leave the spring under tension while not in use. ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 9: Battery Indicator

    A load indicator bar alerts the operator as to how much torque load is being applied to the transducer as related to its full scale rating. ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 10: Zeroing The Tester

    Press the MODE key until “Peak” appears on the display. The display will show the maximum torque applied to the transducer during a cycle. ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 11: Backlit Display

    Output Signal The DTT meter can output data using the supplied mini USB cable (or the optional RS-232 cable, not supplied) and the TorqueLink 2.4 software. TorqueLink 2.4 can be downloaded at www.asg-jergens.com on the Literature and Downloads page. Command...
  • Page 12: Setting

    Press and hold the RESET/SAVE key to reset to zero • • Function of button will change depending on the menu ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 13: Pass-Fail

    Upper Torque Level Level Level Lower Torque Level TIME TIME TIME ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com 15700 44110-3898 888) 486-6163 216) 481-4519 Page 13 of 23...
  • Page 14: Auto Memory

    • If COUNTER-CLOCKWISE is selected in this mode, the auto print feature will work in specific counter-clockwise direction only ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 15: Factory Reset

    VIEW and press ENTER. The display will show the view menu page. Press the MENU/ESC key to return to the memory menu page • ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 16: Delete Last

    • The display will show the transfer memory menu page • Press the ESC key to return to the memory menu page ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 17: Statistics

    If the % offset is between 5%-10%, please contact ASG to arrange a recalibration of your tester • If the % offset is greater than 10%, please contact ASG to arrange for repair or replacement • These values are given only as an indicator – the need for repair may vary according to the individual characteristics of the transducer ASG, Division of Jergens, Inc.
  • Page 18: Date And Time

    Use the UP or DOWN arrow keys to move the cursor to ABOUT and press ENTER. • Press the ESC key to return to the main menu page ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 19: Software

    • Download: For downloading the data in the memory of DTT • Delete Last: To delete data at the end of the table ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 20: Table

    • Data & Time: The date and time the reading was taken Edit the table by double-clicking the cell and then changing it ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 21: Real Time

    When the data does not meet set conditions of upper limit or lower limit, the character will turn to red • In this example, ‘PASS-FAIL’ was not enabled ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 22: Retrieving Information From The Dtt

    4. When the connection is complete, the “Download” button appears. Press the “Download” button to download the data in the DTT meters memory. 5. All information is downloaded into a table. Data is analyzed automatically. ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...
  • Page 23: Capturing Data In Real Time

    • Data that has errors can be corrected manually by double-clicking to edit them directly ASG, Division of Jergens, Inc. S. Waterloo Road | Cleveland, OH | Phone: ( | Fax: ( | Email: asginfo@asg-jergens.com | www.asg-jergens.com...