Voltage Detectors Check
Check the following detectors;
Low battery message detector for alkaline batteries.(2.0 V ± 1 %)
VDET1:
Foced power off detector for alkaline batteries.(1.6V ± 1 %)
VDET2:
Low battery message detector for rechargeable battery.(3.3 V ± 2 %)
VDET1R:
Foced power off detector for rechargeable battery.(3.0 V ± 2 %)
VDET2R:
Low battery message detector for back-up battery.(2.7 V ± 1 %)
VDETS:
Step
Operation
Vb = 2.6 ± 0.02 V
Setting
ENTER, 7, 1
VDET1
Put power supply voltage
down by degrees.
VDET2
Put power supply voltage
down by degrees.
Display (Wiring)
Alkaline battery terminal
-
V
+
Vb
AC adapter
Charger
VDET1
OFF
VDET2
OFF
VDET1R
OFF
VDET2R
(indefinite)
VDET3
OFF
VDETS
ON
Recharge
OFF
CHKPRG
OFF
AC Adapter
USED
Cover
CLOSED
CardLock
CLOSED
Cradle
NOT STAY
VDET1
ON
VDET2
OFF
VDET1
ON
VDET2
ON
— 52 —
Note
Connect the items as
shown.
A-20
Measure the voltage that
VDET1 becomes ON.
VDET1 = 2.0 V ± 5 %
Measure the voltage that
VDET2 becomes ON.
VDET2 = 1.6 V ± 1 %