Summary of Contents for Bang & Olufsen BeoVision 4 – 65 type 8959
Page 1
Plasma Display Panel – 65 HD Type D7 BeoVision 4 – 65, type 8959, 8990 - 8996 Service Manual Danish English, German, French, Italian, Spanish and Dutch versions are available in the Retail System This Service Manual must be returned with the defective parts/back-up suitcase !
Page 2
CONTENTS Survey of modules ..................1.1 How to service .................... 1.2 Fault flow chart ..................... 2 Placement of measuring points ..............3.1 PDP self-check ..................... 3.2 PDP pixel test ....................3.3 Local Screen Failure and OSD menu ............3.4 Replacement of modules ................3.5 Test, adjustment and configuration after repair ........
Page 3
Oversigt over moduler Oversigt over moduler, Plasma Display Panel (PDP) P (SC) P (SS) PC-module Data Drive (Upper left) Line Filter Data Drive (Upper center) Scan Out Data Drive (Upper right) Scan Connection (Lower) Data Drive (Lower right) Sustain Out Sustain Connection (Upper) Data Drive (Lower center) Data Drive (Lower left)
Page 4
Udførelse af service Udførelse af service Servicering PDP’en må kun serviceres af uddannet teknisk personale. Hvis det ikke er muligt at lokalisere fejlen, eller hvis fejlen ikke kan afhjælpes ved at udskifte reservedele, skal det danske servicecenter kontaktes for teknisk support.
Page 5
Udførelse af service Fejlfinding Før fejlfindingen påbegyndes Bed kunden demonstrere eller forklare fejlen. Kontrollér, at Produktet er indstillet på den korrekte Option. Alle ledninger er korrekt tilsluttet. Netspændingen er tilsluttet. Alle eksterne kilder er korrekt tilsluttet, og at produktopsætningen er korrekt. Opsætning til test Forbind følgende produkter for at klargøre opsætningen til test, BeoVision 4, et BeoSystem og en DVD-afspiller.
Page 7
Fejltræ Fejltræ System F900 & F901 på PCB Fejlsymptom: Udskift defekt sikring - TV-kanaler - intet billede PF OK? - PDP stand-by lys = intet lys - Netspænding OK Mulige årsager: - F900 og/eller F901 defekt - Defekt 5V-forsyning - PCB P Bekræft spænding PCB P (SS) STB 5V Udskift PCB P (SS)
Page 8
Fejltræ Vpfc-, Vsus-, Vlow- eller Vda-fejl Fejlsymptom: Udskift PCB P (SC) - Støj i billede, PDP menuen OSD eller PCB P (SS) Mulige årsager: - Støj i PDP - effekt eller digital behandling - Justeret spænding svarer ikke til specifika- tioner - Defekt PCB P, SC eller SS Bekræft/juster...
Page 9
Fejltræ Frakobl RS232-kabel Fejlsymptom: fra PDP’en - Fjernbetjening af PDP ikke mulig - Stand-by lys tændt Mulige årsager: - Kabel til PCB V1 - PCB V1 defekt Tænd for PDP’en ved at trykke på den Kontrollér kabel til første knap fra PCB V1 venstre på...
Page 10
Fejltræ Fejlsymptom: - TV-kanaler - intet billede eller kun sne - PDP stand-by lys blinker Mulige årsager: Blinker - 2 gange: Scan-driver 1, PCB P, SC, SS - 3 gange: 3,3V, PCB D eller P - 4 gange: 5,0V, PCB D eller P - 5 gange: Strømforsyning, PCB P - 6 gange: Blæsereffekt, blæser, PCB SS eller Z...
Page 11
Fejltræ PDP stand-by lys blinker 4 gange Udskift PCB P (SS) Bekræft 5V på - - - - - - - - PCB D D25 ben 6 Ikke 5V fra PCB P Udskift PCB D PDP stand-by lys blinker 5 gange Erstat PCB P (SC) Udskift PCB P (SS) med den gamle...
Page 12
Fejltræ PDP stand-by lys blinker 6 gange - - - - - - - - Defekt blæser Frakobl og tilslut atter netkablet - - - - - - - - Visuel bekræftelse af, at blæser er defekt Alle blæsere tilsluttet Alle blæsere tilsluttet Udskift defekt blæser PCB SS defekte...
Page 13
Fejltræ PDP stand-by lys blinker 9 gange Bekræft, at PCB SS D261 er tændt Bekræft, at PCB SS Bekræft +15V ved - - - - - - - - D063 er tændt? PCB SS P12 ben 4 Tændt = 15V-forsyning OK Bekræft/juster 1.
Page 15
Placering af målepunkter Placering af målepunkter - Brug et ikke-ledende værktøj til justering. R670 (TPVbk) R665 (Vda) R661 (Vlow) R665 (Vda) R641 (Vsus) R641 (Vsus) VR801 (Vad) R443 (PFC) R443 (PFC) VR250 (Ve) Panel label TPVbk TPVsus2 TPVda2 W66 PR401 PR401 TPVda TPVsus...
Page 16
PDP selvkontrol PDP selvkontrol Selvkontrol kontrollerer status på de kredsløb, der er tilsluttet IIC-bussen Hvis PDP’en er monteret i en aluminiumsramme, skal du pege fjernbetjeningen uden navn mod hullet i det forreste, nederste venstre hjørne af PDP’en. Se ➢6. - Se illustrationerne vedrørende: - Placering af knapper på...
Page 17
PDP pixel-test PDP pixel-test Pixel-testen kontrollerer PDP’ens status for at fastslå antallet af defekte pixler Testen skal gennemføres: - Før produktet transporteres til PDP-værkstedet - Før og efter service på PDP’en Hvis PDP’en er monteret i en aluminiumsramme, skal du pege fjernbetjeningen uden navn mod hullet i det forreste, nederste venstre hjørne af PDP’en.
Page 18
Lokal skærmfejl og menuen OSD Lokal skærmfejl PDP’en kan have en fejl i et lokalt område på skærmen. Illustrationen nedenfor viser en mulig sammenhæng mellem fejl og modul. �� ������ �� ������ �� ������ � ������ � ������ � ������ ��...
Page 19
Udskiftning af moduler Udskiftning af moduler Udskiftning af moduler Udskiftning af kontrastskærm Handlinger før demontering af PDP’en Vent mindst 1 minut, efter at du har taget stikket ud af stikkontakten, så de elektrolytiske kondensatorer kan aflades, før du demonterer PDP’en. Tilslut ESD-måtten.
Page 20
Test, justering og konfiguration efter reparation Test, justering og konfiguration efter reparation Konfigurer PDP til B&O menu. Test og justering efter udskiftning af modul(er). Advarsel Der kan opstå burn-in på PDP’en, hvis der vises et still-billede i mere end 30 minutter. Test og justering Test og justering efter udskiftning af modul(er) skal udføres efter enhver reparation af PDP’en.
Page 21
Test, justering og konfiguration efter reparation A LED ➢7 MiCom Software version 2.11 S6 Memory data version 1.20 24 8 63 Memory data version -- -- -- -- Memory data change Address Data...
Page 22
Afsluttende kontrol efter reparation Test og justering efter udskiftning af modul(er) Forberedelser før justering - Tilslut ikke ESD-måtten til PDP’en. - Indstil PDP’en til at modtage et billede. Generér f.eks. et internt billede. Se PDP pixel-test, side 3.3. - Kontrol og justering af spænding kan foretages med et DC-voltmeter (f.eks. et multimeter).
Page 23
PDP in service position Mounting service stands - Remove blinds - Mount service stands incl. brackets - Mount straps - Remove screws for wall bracket...
Page 24
PDP in service position - Lift of PDP and place on floor - Keep your backs straight! - Positioning straps as shown, and keep your backs straight, lift the PDP - Carry the PDP to a place suited for the repair...
Page 25
PDP in service position Remove aluminium frame and back cover - Remove screws holding the aluminium frame TX10 - Remove screws holding the iron frame - Remove screws holding the back cover...
Page 26
Replace contrast screen and plasma frame ☞ 4.1 PDP in service position - Remove plugs SSP34 C4P04 - Remove screws - Pull out front at lift up ➁ ➀ - Remove screws and gently lift out contrast screen...
Page 27
Replace PCB C1, Data Drive (Upper left) ☞ 4.1 PDP in service position - Placement of PCB C1 - Remove screws for FAN, unplug FAN - Remove plugs CAP01 CAP02 CAP03 CAP00 - Open plugs as shown CAP04 CAP03 CAP02 CAP01...
Page 28
Replace PCB C1, Data Drive (Upper left) - Remove screws and genly pull out cables - Remove screws...
Page 29
Replace PCB C2, Data Drive (Upper center) ☞ 4.1 PDP in service position - Placement of PCB C2 - Remove screws for FAN, unplug FAN - Remove plugs CAP03 CAP02 CAP00 CAP04 CAP05 CAP01 - Open plugs as shown CAP08 CAP07 CAP06...
Page 30
Replace PCB C2, Data Drive (Upper center) - Remove screws and genly pull out cables - Remove screws...
Page 31
Replace PCB C3, Data Drive (Upper right) ☞ 4.1 PDP in service position - Placement of PCB C3 - Remove screws for FAN, unplug FAN - Remove plugs CAP05 CAP03 CAP01 CAP02 - Open plugs as shown CAP04 CAP03 CAP02 CAP01...
Page 32
Replace PCB C3, Data Drive (Upper right) 4.10 - Remove screws and genly pull out cables - Remove screws...
Page 33
Replace PCB C4, Data Drive (Lower right) 4.11 ☞ 4.1 PDP in service position - Placement of PCB C4 - Remove screws for FAN, unplug FAN - Remove plugs CBP02 CBP01 CBP03 CBP04 - Open plugs as shown CBP11 CBP10 CBP09 CBP08...
Page 34
Replace PCB C4, Data Drive (Lower right) 4.12 - Remove screws and genly pull out cables - Remove screws...
Page 35
Replace PCB C5, Data Drive (Lower center) 4.13 ☞ 4.1 PDP in service position - Placement of PCB C5 - Remove plugs CBP05 CBP04 CBP00 CBP02 CBP01 CBP03 - Open plugs as shown CBP07 CBP06 CBP05 - Remove screws and genly pull out cables...
Page 37
Replace PCB C6, Data Drive (Lower left) 4.15 ☞ 4.1 PDP in service position - Placement of PCB C6 - Remove screws for H3, remove H3 - Remove plugs CBP02 CBP00 CBP03 - Open plugs as shown CBP04 CBP03 CBP02 CBP01...
Page 38
Replace PCB C6, Data Drive (Lower left) 4.16 - Remove screws and genly pull out cables - Remove screws...
Page 39
Replace PCB D, Digital Signal Processor 4.17 ☞ 4.1 PDP in service position - Placement of PCB D - Remove cables from PCB D and PCB Z ZP05 ZP06 ZP07 ZP08 ZP09 ZP10 ZP30 ZP31 ZP32 ZP33 ZP34 DP01 DP03 DP05 DP20 DP25...
Page 40
Replace PCB D, Digital Signal Processor 4.18 - Remove screws...
Page 41
Replace PCB F, Fuse & Line Filter 4.19 ☞ 4.1 PDP in service position - Placement of PCB F - Remove shield from PCB F - Remove plugs - Remove screws...
Page 42
4.20 Replace PCB HX, PC Type Input Terminal ☞ 4.1 PDP in service position - Placement of PCB HX - Remove plugs on PCB J JP10 - Remove screws on PCB J - Remove screws on backside and remove PCB J...
Page 43
Replace PCB HX, PC Type Input Terminal 4.21 - Remove screws - Remove “screws” on the bottom - Remove screw on PCB HX...
Page 44
Replace PCB J, Slot Interface & SYNC processor 4.22 ☞ 4.1 PDP in service position - Placement of PCB J - Remove plugs on PCB J JP10 - Remove screws on PCB J - Remove screws on backside and remove PCB J...
Page 45
Replace PCB P (SC), Power Supply (left) 4.23 ☞ 4.1 PDP in service position - Placement of PCB P (SC) - Remove plugs PP02 PP07 PP09 PP10 PP11 PP12 PP23 PP25 PP27 PP700 - Remove screws...
Page 46
Replace PCB P (SS), Power Supply (right) 4.24 ☞ 4.1 PDP in service position - Placement of PCB P (SS) - Remove plugs PP02 PP05 PP07 PP09 PP10 PP11 PP12 PP25 PP27 PP700 - Remove screws...
Page 47
Replace PCB PC, Power Supply Interface 4.25 ☞ 4.1 PDP in service position - Placement of PCB PC - Remove plugs PCP700 PCP701 - Remove screws...
Page 48
Replace PCB PF, Line Filter 4.26 ☞ 4.1 PDP in service position - Placement of PCB PF - Remove cover and plugs PFP01 PFP02 PFP09 PFP10 - Remove GND wires - Remove screws...
Page 49
Replace PCB SC, Scan Out 4.27 ☞ 4.1 PDP in service position - Placement of PCB SC - Remove FAN - Remove PCB SU as shown SCP45 - Remove PCB SD as shown SCP46...
Page 50
Replace PCB SC, Scan Out 4.28 - Remove plugs SCP02 SCP10 SCP11 SCP12 SCP13 SCP20 SCP23 SCP62 - Remove screws - Very gentle pull out PCB SC...
Page 51
Replace PCB SD, Scan Connection (Lower) 4.29 ☞ 4.1 PDP in service position - Placement of PCB SD - Remove PCB SD as shown SCP46 - Remove cables on backside of PCB SD SDP1 SDP2 SDP3 SDP4...
Page 52
Replace PCB SU, Scan Connection (Upper) 4.30 ☞ 4.1 PDP in service position - Placement of PCB SU - Remove PCB SU as shown SUP45 - Remove cables on backside of PCB SU SUP1 SUP2 SUP3 SUP4...
Page 53
Replace PCB SS, Sustain Out 4.31 ☞ 4.1 PDP in service position - Placement of PCB SS - Remove FAN tower - Remove plugs on PCB SS2 and PCB SS3 SS2P23 SS2P24 SS3P27 SS3P28 - Remove plugs SSP01 SSP02 SSP03 SSP04 SSP05 SSP10...
Page 55
Replace PCB SS2, Sustain Connection (Upper) 4.33 ☞ 4.1 PDP in service position - Placement of PCB SS2 - Open plugs as shown and remove plugs SSP51 SSP52 SSP23 SSP24 - Remove plugs SSP51 SSP52 - Remove screws...
Page 56
Replace PCB SS3, Sustain Connection (Lower) 4.34 ☞ 4.1 PDP in service position - Placement of PCB SS3 - Open plugs as shown and remove plugs SSP23 SSP24 SSP57 SSP58 - Remove plugs SSP57 SSP58 - Remove screws...
Page 57
Replace PCB Z, Audio out 4.35 ☞ 4.1 PDP in service position - Placement of PCB Z - Remove cables from PCB Z ZP05 ZP06 ZP07 ZP08 ZP09 ZP10 ZP30 ZP31 ZP32 ZP33 ZP34 - Remove srews and pull of PCB Z...
Page 59
Specification guidelines for service use Specification guidelines for service use Plasma Display Panel – 65HD, Type D7 Mains voltage 230V (198V – 264V) 50Hz, 120V (90V – 132V) 60Hz Power consumption Typical: 635W, standby 1.0W, power off: 0.3W Dimensions without handles (W x H x D) 1554mm x 925mm x 99mm, 61.18in x 36.42in x 3.90in Weight 81.0kg (178.6Lb)
Page 62
Available parts Survey of modules - Plasma Display Panel P (SC) P (SS) PC-module 8002320 PC Board C1 8002321 PC Board C2 8002327 PC Board C3 8002328 PC Board C4 8002329 PC Board C5 8002330 PC Board C6 8003021 PC Board D 8002229 PC Board F 8002228...
Page 63
Available parts Packing 9301 9302 9303 9304 9304 9305 9302 9301 9306 9301 3392406 Outer box, top/bottom 9302 3396299 Set of foam, top and bottom 9303 3917105 Foam foil 9304 3392407 Outer box, side 9305 3392200 Distance pipe 9306 3392419 Pallet 3375424 Tip and tell...
Page 64
Available parts Accessories 6270099 RGB/RS 232 cable, 5m black 6270115 RGB/RS 232 cable, 10m black 6270116 RGB/RS 232 cable, 15m black 6270117 RGB/RS 232 cable, 20m black 3395264 Back-up suitcase Back-up suitcase 3375447 Product cover Parts not shown 8053466 Special remote control 3375706 Micro fibre cloth 3390436 Bag w/wall bracket f/IR sensor 3390519 Bag w/rear plate f/IR sensor...
Need help?
Do you have a question about the BeoVision 4 – 65 type 8959 and is the answer not in the manual?