Setup And Operation; Setup - ADC RF Wofx User Manual

Dual a/b switch wit automatic switchback
Table of Contents

Advertisement

ADCP-61-813 • Issue 2 • February 2005
5. Place the fuse module back into the power inlet module, making sure that the fuse module
is seated properly.
6. Close the power inlet module door, making sure that it snaps firmly into place, and that
"115V" does show through the window.
7. Connect the correct type of power cord corresponding to the local electrical code.
8. The front panel (green) NORMAL and (red) FAILURE LED's will be lit, indicating that
the internal power supply is operational. Then proceed to Section 5 to set up and operate
the switch.

5 SETUP AND OPERATION

5.1

Setup

Power-up (plug in) the RDS-AS. (The front panel status should indicate normal and failure
status.) As a special feature, the system performs internal diagnostics to ensure proper
operation. After power-up a lower case "C" will be displayed for one minute. The "C" will
immediately disappear if communication with the Swatch switch monitoring software is
established. In rare instances an A or B may show continuously in the display when powering
up. This indicates that an internal failure has occurred. Contact ADC
Note: After initial power-up, the 7-segment display
status for PORT 1 and PORT 2 by flashing either the top or bottom segment for
approximately two seconds, then displaying threshold and status information for the
associated port (1 or 2).
Toggle the threshold switch to the "up" position to configure PORT 1. The display will then
lock on to the status indications for this port.
Note: If no changes are made within 15 seconds, the display will revert to its alternating
PORT 1/PORT 2 flashing display.
While locked onto PORT 1, calibrate the base level of the receiver using the calibration
procedure described in
Page 10
© 2005, ADC Telecommunications, Inc.
100/120VAC OR 240 VAC
FUSE
MODULE
Figure 12. Power Inlet Module
Section
5.1.1.
20372-A
WINDOW
(Section
(Figure
13) will alternately indicate
7) for assistance.