Sr5005 - Protection History Display Mode (3 Of 3) - Marantz SR5005 Model Information

Hide thumbs Also See for SR5005:
Table of Contents

Advertisement

Model Information
Index
Clearing the Protection History
If the unit is in "Protection History Display Mode", just press and hold the "ENTER" button for 3 seconds. Note: If you do not mind
erasing your settings from this unit, you can also "Initialized/Micro Reset the unit to clear the Protection History from the unit's
memory.
If the unit is not in "Protection History Display Mode", enter the "Protection History Display Mode":
1. Press and hold the "STATUS" and the "CURSOR" buttons at the same time and press the "POWER" button to turn on the
power.
2. Press the "STATUS" button to turn on the FL display.
Press and hold "ENTER" for 3 seconds.
Press and hold "ENTER" for 3 seconds and "CLEAR"
is displayed followed by "NO PROTECT". The unit's
Protection History is now cleared.
Warning Displays by POWER LED
If the power is turned off while a protection is detected, the POWER LED (red) flashes in the following ways as a warning according
to the protection status.
(a) ASO/DC protection: Flashes in 0.5-second cycles (0.25 seconds lit, 0.25 seconds unlit)
(b) THERMAL protection: Flashes in 2-second cycles (1 seconds lit, 1 seconds unlit)
Protection History Display Mode Procedure

SR5005 - Protection History Display Mode (3 of 3)

L1
FLD
L2
L3
FLD
L3
FLD
L3
P
R
O
T
E
C
H
I
S
T
O
:
D
C
C
L
E
A
R
:
N
O
HOME
Front Panel and Button Locations
T
R
Y
20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents