Hide thumbs Also See for AC100KXADEH:

Advertisement

Quick Links

Air conditgioner
Air conditioner
User manual/Installation manual
Installation manual
AR✴✴HVSD✴✴
AC✴✴✴KNPDEH/AC✴✴✴KXAD✴H
• Thank you for purchasing this Samsung air conditioner.
• Thank you for purchasing this Samsung air conditioner.
• Before operating this unit, please read this user manual carefully and retain it for future
• Before operating this unit, please read this user manual carefully and retain it for future
reference.
reference.

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AC100KXADEH

  • Page 1 Installation manual AR✴✴HVSD✴✴ AC✴✴✴KNPDEH/AC✴✴✴KXAD✴H • Thank you for purchasing this Samsung air conditioner. • Thank you for purchasing this Samsung air conditioner. • Before operating this unit, please read this user manual carefully and retain it for future • Before operating this unit, please read this user manual carefully and retain it for future reference.
  • Page 2: Table Of Contents

    Step 18 Performing the final check and trial operation Appendix COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Troubleshooting For information on Samsung’s environmental commitments and product specific regulatory obligations e.g. REACH visit: samsung.com/uk/aboutsamsung/samsungelectronics/corporatecitizenship/data_corner.html English...
  • Page 3: Safety Information

    ∙ This manual explains how to install an indoor unit ∙ This product has been determined to be in compliance with a split system with two SAMSUNG units. The use with the Low Voltage Directive (2006/95/EC), and the of other types of units with different control systems Electromagnetic Compatibility Directive (2004/108/ may damage the units and invalidate the warranty.
  • Page 4: Installing The Unit

    Safety Information Installing the unit ∙ Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety IMPORTANT: When installing the unit, always remember standards. to connect first the refrigerant tubes, then the electrical lines.
  • Page 5 ∙ Do not install the air conditioner in following places. – Place where there is mineral oil or arsenic acid. Resin parts flame and the accessories may drop or water may leak. The capacity of the heat exchanger may reduce or the air conditioner may be out of order.
  • Page 6: Installation Procedure

    Installation Procedure Step 1 Choosing the installation ∙ Install the unit where the pipes and cables can be easily connected to the indoor unit. location ∙ Maintain sufficient space for repairs and service. Determine the installation location considering the ∙ Make sure that condensed water dripping from the following conditions and obtain the user approval.
  • Page 7 ∙ Construct a protection wall made of solid material such as concrete to block sea breeze. Make sure that 600 or more 300 or more its height and width are 1.5 times greater than the 300 or more size of the outdoor unit. In addition, secure a space larger than 600 mm between the protection wall and 1500 or more the outdoor unit for exhausted air to ventilate.
  • Page 8 Installation Procedure ∙ A ventilation system is required when the outdoor WARNING unit is installed in a closed space or room, even though R-410A is not poisonous or flammable. ∙ After installing the outdoor unit, apply rust inhibitor on the internal pipes and heat exchanger. ∙...
  • Page 9: Step 2 Unpacking

    Step 2 Unpacking M4 X L12 screws (4) M4 X L14 screws (4) Unpacking the indoor unit 1 Open the indoor unit package. Pipe outlet protection Insulation for drain hose 2 Remove the top and middle cushions. rubber (1) 3 Remove the bottom cushion. Unpacking the outdoor unit 1 Pull out the outdoor unit from the package.
  • Page 10: Step 5 Taping The Pipes, Cables, And Drain Hose

    Step 6 Connecting the refrigerant drain hose pipes 1 Wrap the refrigerant pipes with the provided Items Maximum allowable length insulation. This wrapping minimises condensation. Outdoor unit AC100KXADEH AC140KXADGH models Insulation Main pipe (L1) 50 m 75 m Max. height...
  • Page 11 1 Connect each assembly pipe to the appropriate valves on the indoor and outdoor units and fasten the flare nuts. 2 As depicted in the illustration below, tighten the flare nut manually, and then apply the following torque with a torque wrench. Pipe Flare Indoor unit...
  • Page 12: Step 7 Optional: Cutting And Flaring The Pipes

    Installation Procedure Step 7 Optional: Cutting and flaring Step 8 Connecting the power and the pipes communication cables 1 Make sure that you have the required tools; pipe Electrical work must be done by the certified personnel. cutter, reamer, flaring tool, and pipe holder. ∙...
  • Page 13 More than 4.5 Connecting the cables Less than 15 More than 8.4 AC100KXADEH Connecting the cable to the power terminal ∙ This product uses a single phase power, with 220 to 240V supply. Connect the cables to the terminal board with the ring terminals.
  • Page 14 Installation Procedure Entire system diagram ∙ When connecting the communication and outdoor-to- indoor power cables, make sure these cables do not Communication cable touch the service valve on the refrigerant pipe on the Outdoor-to-indoor power cable gas side or the pipes, without proper insulation. Fix the Main power cable Electrical panel outdoor-to-indoor power cables to the insulated pipes.
  • Page 15 Total Volts Min. Max. Cooling Heating AC100KNPDEH 220-240 21.7 21.7 23.2 23.2 29.0 AC100KXADEH AC140KXPDEH 380-415 456.5 14.6 14.6 16.1 16.1 16.1 16.1 AC140KXADGH NOTE 1 Voltage range ∙ Units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits 2 Maximum allowable voltage variation between phases is 2%.
  • Page 16: Step 9 Optional: Extending The Power Cable

    Installation Procedure Step 9 Optional: Extending the power 4 Using a crimping tool, compress the two points and flip it over and compress another two points in the same location. cable ∙ The compression dimension should be 8.0. 1 Prepare the following tools. Tools Spec Shape...
  • Page 17: Step 10 Checking The Earthing

    4 Install a green/yellow coloured earthing wire: CAUTION ∙ If the earthing wire is too short, connect an ∙ Make sure that the connection parts are not exposed extension lead in a mechanical way and wrap it to outside. with insulating tape (do not bury the connection). ∙...
  • Page 18: Step 12 Evacuating The Air

    Installation Procedure 1 Connect the charging hose of low pressure side of Step 13 Charging the refrigerant manifold gauge to the packed valve having a service port as shown at the figure. Important information regulation regarding the refrigerant used NOTE ∙...
  • Page 19 Refrigerant amount R-410A: Thread of the screw -1/2-2OUNF Standard Additional Tightening torque for charging port cap (Refer to the table) Model name (less 30m) (over 30m) AC100KXADEH 3000 Tightening torque Outer diameter AC140KXADGH 3500 Body cap Charging port cap (mm) (N•m)
  • Page 20 Installation Procedure Pressure table for each temperature If extra refrigerant charging is required due to gas leakage or product relocation, see the following table. Pipe insulation Cooling operation Unit: [kPa, G] Indoor temperature (°C) (Dry bulb / Insulator for pipe 32/23 27/19 21/15...
  • Page 21: Step 15 Installing And Connecting The Drain Hose

    Step 15 Installing and connecting the drain hose 1 Wrap the drain hose with the provided insulation. This wrapping minimises condensation. Indoor unit Drain hose Insulation ∙ When the hole of the drain hose on the wall is higher than that of the drain hose connection Indoor unit 2 Insert the end of the drain hose to the extension drain hose to make a connection.
  • Page 22: Step 17 Checking The Earthing

    Installation Procedure 3 Press K1 or K2 on the outdoor unit PCB to run the CAUTION test mode and stop. ∙ Install the drain hose in a downward direction. ∙ Press K1 button → Start Heating test mode → Press K1 button twice →...
  • Page 23 6 View mode: When the K4 switch is pressed, you can see information about our system state, as detailed below. short Display contents SEG1 SEG2 SEG3 SEG4 Unit push Order frequency Hundreds digit Tens digit Units digit Current frequency Hundreds digit Tens digit Units digit The number of...
  • Page 24 Installation Procedure 7 DIP switch option 8 Silence Mode DIP switch option ∙ DIP switch (SW507) option Switch 3 Switch 4 Operation Disable Silence mode Silence mode 1st step Silence mode 2nd step Silence mode 3rd step ∙ DIP switch (SW507) option On (default) Switch 1 Auto address...
  • Page 25: Appendix

    Appendix COMMISSION DELEGATED REGULATION (EU) No 626/2011 PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS) Supplier's name Samsung Electronics Co., Ltd. Model name (Indoor/Outdoor) AC100KNPDEH/AC100KXADEH Sound Power Level (Indoor/Outdoor) dB(A) 60 / 70 Refrigerant name R-410A 2088 SEER Energy efficiency class (SEER)
  • Page 26 Appendix [Spanish-ES] [French-FR] [Italian-IT] [Portuguese-PT] REGOLAMENTO DELEGATO REGULAMENTO DELEGADO REGLAMENTO DELEGADO (UE) RÈGLEMENT DÉLÉGUÉ (UE) No (UE) N. 626/2011 DELLA (UE) N.o 626/2011 DA No 626/2011 DE LA COMISIÓN 626/2011 DE LA COMMISSION COMMISSIONE COMISSÃO Fiche produit (l'indication, Ficha del producto Scheda prodotto (l'etichettatura Ficha de produto (rotulagem par voie d'étiquetage, de la...
  • Page 27 [German-DE] [Greek-EL] [Dutch-NL] [Polish-PL] ΚΑΤ’ ΕΞΟΥΣΙΟΔΌΤΗΣΗ DELEGIERTE VERORDNUNG GEDELEGEERDE ROZPORZĄDZENIE ΚΑΝΟΝΙΣΜΌΣ (ΕΕ) αριθ. (EU) Nr. 626/2011 DER VERORDENING (EU) VAN DE DELEGOWANE KOMISJI (UE) nr 626/2011 ΤΗΣ ΕΠΙΤΡΟΠΉΣ KOMMISSION COMMISSIE Nr. 626/2011 626/2011 Produktdatenblatt (die Δελτίο προϊόντος (επισήμανση Productkaart (energie- Karta produktu (etykiet Kennzeichnung von της...
  • Page 28 Appendix [Hungarian-HU] [Czech-CS] [Slovak-SK] [Romanian-RO] NAŘÍZENÍ KOMISE V A BIZOTTSÁG 626/2011/EU DELEGOVANÉ NARIADENIE REGULAMENT DELEGAT (UE) PŘENESENÉ PRAVOMOCI (EU) FELHATALMAZÁSON ALAPULÓ KOMISIE (EÚ) č. 626/2011 NR. 626/2011 AL COMISIEI č. 626/2011 RENDELETE Termékismertető adatlap (a Informační list (energie Fișa produsului (etichetarea légkondicionáló...
  • Page 29 [Bulgarian-BG] [Croatian-HR] [Slovenian-SL] [Danish-DA] KOMMISSIONENS DELEGEREDE ДЕЛЕГИРАН РЕГЛАМЕНТ (ЕС) DELEGIRANA UREDBA DELEGIRANA UREDBA FORORDNING (EU) Nr. № 626/2011 НА КОМИСИЯТА KOMISIJE (EU) br. 626/2011 KOMISIJE (EU) št. 626/2011 626/2011 Informacijski list proizvoda Podatkovna kartica izdelka Продуктов фиш (енергийното Datablad (energimærkning af (označivanja energetske (energijskim označevanjem етикетиране...
  • Page 30 Appendix [Swedish-SV] [Finnish-FI] [Estonian-ET] [Latvian-LV] KOMMISSIONENS KOMISJONI DELEGOITU KOMISSION DELEGERADE KOMISIJAS DELEĢĒTĀ DELEGEERITUD MÄÄRUS ASETUS (EU) N:o 626/2011, FÖRORDNING (EU) nr REGULA (ES) Nr. 626/2011 (EL) nr 626/2011, 626/2011 Tuoteseloste Produktblad Tootekirjeldus Ražojuma speciālā zīme (huoneilmastointilaitteiden (energimärkning av (kliimaseadmete (gaisa kondicionētāju energiamerkinnän osalta) luftkonditioneringsapparater) energiamärgistusega)
  • Page 31 [Lithuanian-LT] [Serbian-SR] KOMISIJOS DELEGUOTASIS КОМИСИЈА ДЕЛЕГАТЕД REGLAMENTAS (ES) Nr. УРЕДБА (ЕС) № 626/2011 626/2011 Gaminio vardinių parametrų ПРОИЗВОДА ФИЦХЕ lentelė (oro kondicionierių (енергетског означавања клима energijos vartojimo уређаја) efektyvumo ženklinimo reikalavimus) kWh/godišnje kWh/a Naziv dobavljača Tiekėjo pavadinimas Naziv modela (unutršnja jedinica/ Modelis pavadinimas spoljašnja jedinica) (patalpoje / lauke)
  • Page 32 Appendix [Spanish-ES] 1 Las fugas de refrigerante contribuyen al cambio climático. Cuanto mayor sea el potencial de calentamiento global (GWP) de un refrigerante, más contribuirá a dicho calentamiento su vertido a la atmósfera. Este aparato contiene un líquido refrigerante con un GWP igual a [xxx]. Esto significa que, si pasara a la atmósfera 1 kg de este líquido refrigerante, el impacto en el calentamiento global sería, a lo largo de un periodo de 100 años, [xxx] veces mayor que si se vertiera 1 kg de CO2.
  • Page 33 [Portuguese-PT] 1 A fuga de fluido refrigerante contribui para as alterações climáticas. Os fluidos refrigerantes com menor potencial de aquecimento global (PAG) contribuem menos para o aquecimento global do que os fluidos refrigerantes com maior PAG, em caso de fuga para a atmosfera. Este aparelho contém um fluido refrigerante com um PAG igual a [xxx].
  • Page 34 Appendix [Dutch-NL] 1 Lekkage van koelmiddel leidt tot klimaatverandering. Bij lekkage in de lucht draagt een koelmiddel met een laag aardopwarmingsvermogen (GWP) minder bij tot de opwarming van de aarde dan een koelmiddel met een hoog GWP. Dit apparaat bevat een koelmiddel met een GWP gelijk aan [xxx]. Dit houdt in dat als 1 kg van deze koelvloeistof in de lucht vrijkomt, het effect op de aardopwarming over een periode van 100 jaar [xxx] keer groter zou zijn dan bij het vrijkomen van 1 kg CO2.
  • Page 35 [Czech-CS] 1 Únik chladiva se podílí na změně klimatu. Chladivo s nižším potenciálem globálního oteplování (GWP) by se v případě úniku do ovzduší podílelo na globálním oteplování méně než chladivo s vyšším GWP. Toto zařízení obsahuje chladicí kapalinu s GWP ve výši [xxx]. To znamená, že pokud by do ovzduší unikl 1 kg této chladicí kapaliny, dopad na globální...
  • Page 36 Appendix [Bulgarian-BG] 1 Изпускането на хладилен агент допринася за изменението на климата. Хладилен агент с по-нисък потенциал за глобално затопляне (ПГЗ) би допринесъл по-малко за глобалното затопляне, отколкото хладилен агент с по-висок ПГЗ при евентуално изпускане в атмосферата. Настоящият уред съдържа хладилен агент с ПГЗ в размер на [xxx]. Това означава, че ако 1 kg от хладилния...
  • Page 37 [Swedish-SV] 1 Läckage av köldmedium bidrar till klimatförändringen. Köldmedium med lägre global uppvärmningspotential (GWP) skulle vid läckare ge upphov till mindre global uppvärmning än ett köldmedium med högre GWP. Den här apparaten innehåller ett köldmedium med GWP motsvarande [xxx]. Det betyder att om 1 kg av köldmediet skulle läcka ut i atmosfären, skulle påverkan på...
  • Page 38 Appendix [Lithuanian-LT] 1 Šaldalo nuotėkis prisideda prie klimato kaitos. Jei šaldalo nutekėtų į atmosferą, mažesnį visuotinio atšilimo potencialą turintis šaldalas mažiau prisidėtų prie visuotinio atšilimo negu didesnį visuotinio atšilimo potencialą turintis šaldalas. Šiame prietaise yra skysto šaldalo, kurio visuotinio atšilimo potencialas yra [xxx]. Tai reiškia, kad jei 1 kg šio šaldalo nutekėtų...
  • Page 39 Troubleshooting The table below lists the self-diagnostic routines. For some of error codes, you must contact an authorized service centre. If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB.
  • Page 40 Appendix Error Code Meaning Remarks E470 Outdoor unit EEPROM Checksum error Check Outdoor EEPROM Data E471 Outdoor unit EEPROM error Check Outdoor EEPROM PBA Error on IPM (IGBT Module) or PFCM E474 Check Outdoor Inverter PBA temperature sensor E475 Error on inverter fan 2 FAN2 error E484 PFC overload (over current) error...
  • Page 41 Memo English...
  • Page 42 Memo English...
  • Page 43 Memo English...

This manual is also suitable for:

Ac100knpdehAc140kxadghAc140kxpdeh

Table of Contents