Ro 1-Bit; Ro 8/16-Bit - ABB AquaMaster 3 Manual

Electromagnetic flowmeter
Hide thumbs Also See for AquaMaster 3:
Table of Contents

Advertisement

AquaMaster 3
Electromagnetic flowmeter

1.3.2 RO 1-Bit

Read-only access to single bit types.
Read Discrete Inputs 501 to 503
Read all RO 1-bits
Request Message
Address
Function
Starting Address Hi
Starting Address Lo
Quantity of Inputs Hi
Quantity of Inputs Lo
CRC
CRC
*Outputs status = 06
Output status
Bit
Register
Value
0
501
0
1
502
1
2
503
1
3 to 7 —

1.3.3 RO 8/16-Bit

Read-only access to 8- and 16-bit types.
8-Bit quantities use the Lo byte of Register Value. The Hi byte is 'don't care' and shows value 0 in
Response Messages.
Read Input Register 1002
var12 – Flow sensor settling time (battery power) (16-bit)
Request Message
Address
Function
Starting Address Hi
Starting Address Lo
Quantity of Inputs Hi
Quantity of Inputs Lo
CRC
CRC
*Register Value = 01d1h = 465
MODBUS Tables Supplement COI/FET2XX/MOD/TBL-EN
(Hex)
Response Message
01
Address
02
Function
01
Byte Count
f4
Outputs Status*
00
CRC
03
CRC
78
05
Variable
007
008
416
(Hex)
Response Message
01
Address
04
Function
03
Byte Count
e9
Register Value Hi*
00
Register Value Lo*
01
CRC
e0
CRC
7a
(Hex)
Error Message
01
Function
02
Exception Code
01
06
21
8a
Meaning
Flow sensor is not reverse wired
Flow sensor is a Probe
MID (read only switch) is Active
Not Used
(Hex)
Error Message
01
Function
04
Exception Code
02
01
d1
78
fc
MODBUS Protocol
(Hex)
82
Exception Code
(Hex)
84
Exception Code
5