Owner's Manual for the Redman Power Chair 107 ZRX
Optional accessories, such as automotive horn and 12-volt outlet are
connected to the batteries with separately fused circuits. Please check the
fuses if you are experiencing any problem with the automotive horn and/or
12-volt outlet. The fuses are located on the exterior of the battery box.
Power wheelchair veers left or right
Power wheelchair has sluggish turn
performance
Front casters flutter
All other control components are under the power chair, in the event of a power failure of motor check to
make sure connections are tight. The ISM controls the actuators for positioning. If the chair will not stand or
positioning systems fail try a re-set by disconnecting the main power at the circuit breaker. Leave the circuit
breaker pulled out for 8-10 minutes before pushing back in. If the component is defective and the chair will
not stand to access the ISM you might have to remove the seat pan to access.

Mechanical Troubleshooting

Body Positioning Troubleshooting
Check for correct and equal tire pressure
Check for correct and equal tire pressure.
Adjust turn acceleration.
Check for correct and equal tire pressure.
Check for loose front stem nuts/bolts