Procedure Of Usage; At The Time The Operation Is Over; The Holding’s Adjustment - HASHIMA HP-450CS Instruction Manual

Compact fusing press
Table of Contents

Advertisement

Procedure of usage

1. Set the power source to 'ON'.(Ensure the 'off ' condition of the timer switch.)
2. Press the start button. The lamp will light up and the machine will start
moving.
3. Set pressure to the designated by using the pressure adjust knob.
4. Set the fusing time by using the speed controller .Use it within the limit
between 5 and 20 seconds for the warp prevention.
5. Set the setting temperature by using the thermostat .It takes about 15
minutes before you'll get the usable thermo-lamp will start blinking.
6. Here, you are able to start the operation.

At the time the operation is over.

1. Set the pressure to 0(zero).
2. Set the timer switch to 'ON'. The machine stop automatically and the
surface temperature of the belt is below 100 degrees.
3. When the machine has stopped , set the power source breaker to 'OFF'.
The holding's adjustment
In the case where you want to strengthen the holding at the injecting entrance
of the machine when you've put the inside belt scale, pocket folding and others to
use, turn the holding's handle to the right. Set the holding's adjustment to
0(zero),when you try to fuse the interlining.