WATER ON TOP COOKING RANGE (NATURAL GAS)
SET UP PROCEDURE
The Appliance must be set up using the following procedure:
FOR CEFT50, 41, 40, 32, 31, 30, 21, 20,10
Inlet pressure at its nominal according to gas being used. Light all burners at full rate. Adjust
the 1" governor so that the burner pressure is reading 15.0 mbar. For an ungoverned
appliance, ensure the correct nominal inlet pressure. After setting the governor, it must be
sealed immediately and may not be adjusted by the user.
FOR CEFT54, 53, 52, 51, 43, 42
Inlet pressure at its nominal according to gas being used. Light all burners at full rate. Adjust
the 1½" governor so that the burner pressure is reading 16.0 mbar. For an ungoverned
appliance, ensure the correct nominal inlet pressure. After setting the governor, it must be
sealed immediately and may not be adjusted by the user.
Page 5 of 10
Installation instructions and user guide