Service Logbook; Service Checklist - Far East Europe CEFT54 Installation And User Manual

Water on top wok cooking range (natural gas)
Table of Contents

Advertisement

WATER ON TOP COOKING RANGE (NATURAL GAS)

SERVICE LOGBOOK

Your cooker should be serviced by a Gas Safe engineer certified to work on industrial catering
equipment, at least once every 12 months. For heavy usage this frequency should be
increased to every 6 months. Failure to do so will have a serious impact on your cookers
reliability and will invalidate your warranty or guarantee. You should ensure the engineer
completes the service log overleaf as evidence of having the appropriate work performed.
Far East Europe Ltd recommends using parts and accessory products on this cooker that are
specifically approved for this purpose by us. These parts and products have been functionally
tested for safety and reliability by us. Original parts and accessories, and accompanying
expert advice can be obtained by contacting our Service and Parts hotline on 01246 25 11 77
or visiting our website www.FarEastWok.com.
Your wok cooker is supplied with 2x replacement pilot lights, 2x replacement thermocouples
and 1x custom-sized allen key for adjusting the valve handles. These should be installed/used
by suitably qualified persons only.
COOKER DATA
Model: _______________
I hereby confirm that the appliance above has been installed to a satisfactory and legal standard
Date of installation:_____/_____/______
Installer's name (print): ___________________
Business name (if applicable): ________________
I hereby confirm I have taken delivery of my Far East Europe Ltd wok cooker
Owner's name (print): ___________________ Owner's signature :_______________

SERVICE CHECKLIST

Gas safety check (pipes, valves, manifold inspection; pressure test; leak check)
Inspect and grease all CE gas valves
Clean burners and all jets
Inspect water valves and pipework, repair/replace as required
Inspect pilot lights, replace as required
Inspect thermocouples, replace as required
Visual check for corrosion and heat erosion of all metal parts, repair/replace as
required
SERVICE ONE
– TO BE COMPLETED 12 MONT HS AFTER INSTALLATION
I hereby confirm that the appliance has been serviced in accordance with the service checklist
Service logbook
Serial No: _______________
Installer's signature :_______________
Gas Safe Badge No:____________
Gas Safe Cert No:____________
FAR EAST EUROPE LTD
Gas: N.G. L.P.G