3-7. CAPACITY CORRECTION TABLE BY TEMPERATURE
(3) M-SERIES COOLING CORRECTION
70
60
1.11
63
1.16
64
1.18
68
1.23
72
1.28
75
1.34
79
1.38
(4) M-SERIES DEFROST CORRECTION
Outdoor
intake
43
temperature
W.B. [° F]
Outdoor
intake
6
temperature
W.B. [° C]
Correction
1.00
factor
Due to continuing improvement, above specification may be subject to change without notice.
MSZ-GE-32
2013 M-Series - MSZ-GE Heat Pump Systems (June 2013)
77
81
1.06
1.01
1.10
1.06
1.13
1.08
1.18
1.14
1.23
1.20
1.29
1.26
1.34
1.32
39
36
32
4
2
0
0.80
0.82
0.84
86
95
0.97
0.91
1.02
0.96
1.04
0.98
1.10
1.03
1.15
1.09
1.22
1.15
1.28
1.21
28
25
21
-2
-4
-6
0.87
0.90
0.93
104
115
0.83
0.76
0.88
0.81
0.90
0.83
0.96
0.89
1.02
0.95
1.08
1.02
1.14
1.07
18
14
-8
-10
0.96
1.00