Muy-Ge18Na-1; Muy-Ge24Na - Mitsubishi Electric MSY-GE09NA-8 Engineering Manual

M-series msy/muy-ge-na2 cooling only wall-mount air system
Hide thumbs Also See for MSY-GE09NA-8:
Table of Contents

Advertisement

3-5. REFRIGERANT SYSTEM DIAGRAMS

MUY-GE18NA-1

Refrigerant pipe ø 1/2
(with heat insulator)
Stop valve
(with service port)
Flared connection
Flared connection
Stop valve
(with strainar)
Refrigerant pipe ø 1/4
(with heat insulator)

MUY-GE24NA

Refrigerant pipe ø 5/8
(with heat insulator)
Stop valve
(with service port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe ø 3/8
(with heat insulator)
Due to continuing improvement, above specification may be subject to change without notice.
MSY-GE-NA2-26
M-Series - MSY/MUY-GE-NA2 Wall-Mount Systems (August 2014)
Muffler
#100
4-way valve
Discharge
temperature
thermistor
RT62
Service port
Compressor
LEV
Receiver
Capillary tube
O.D. 0.142 × I.D. 0.094
× 1-31/32
(ø 3.6 ×ø 2.4 × 50)
Muffler
#100
4-way valve
Discharge
temperature
thermistor
Service
RT62
port
Compressor
LEV
Strainer
#100
Capillary tube
O.D.0.157 × I.D.0.094
× 3-15/16
(ø 4.0 ×ø 2.4 × 100)
Service port
Outdoor
heat
exchanger
Outdoor heat
exchanger
temperature
thermistor
RT68
Strainer
#100
Refrigerant flow in cooling
Service
port
Outdoor
heat
exchanger
Outdoor heat
exchanger
temperature
thermistor
RT68
Strainer
#100
Refrigerant flow in cooling
Unit: inch
Ambient
temperature
thermistor
RT65
Ambient
temperature
thermistor
RT65
© 2014 Mitsubishi Electric US, Inc.