Mitsubishi FB18KT Service Manual page 32

Controller
Table of Contents

Advertisement

Setup Options (Group 2)
Option
Title of Option
#
Auxiliary Input for or inhibit lifting or reduce power
#11
Lift and Drive
Speed 1
Auxiliary Travel
#12
Speed Limit 1
Auxiliary Power
#13
Reduction 1
Auxiliary Input for
#14
Lift and Drive
Speed 2
Auxiliary Travel
#15
Speed Limit 2
Auxiliary Power
#16
Reduction 2
Auxiliary Input for
#17
Lift and Drive
Speed 3
Auxiliary Travel
#18
Speed Limit 3
Auxiliary Power
#19
Reduction 3
#20
Stall Timer
#21
Regen Function
Regen Adjustment
#22
for Lever Reg
Regen Adjustment
#23
for Auto Reg
#24
Chat Timer
#25
Seat Switch Timer
#26
Speed Alarm
Tire Size
#27
Adjustment
Description
When the auxiliary input signal is
on, the controller will limit top speed
according to the selection. The speed
limit set by this operation is prior to
#7 top travel speed limit.
Travel speed limit for #11
Power reduction ratio for #11
Same as #11
Travel speed limit for #14
Power reduction ratio for #14
Same as #11
Travel speed limit for #17
Power reduction ratio for #17
If a drive motor stalls for the amount
time set by this option, the motor
current gets to 0.
2 regen modes
5 characteristic curves of lever regen
5 characteristic curves of auto regen
Sets the amount time before the truck
enters chat mode.
If the operator leaves the seat for the
amount of time set by this option,
the line contactor will turn off.
If the truck reaches to the speed set
by this option, the controller outputs
a speed alarm signal.
Adjusts the tire diameter. It changes
the truck's speed recognition and the
speedometer.
0: Turned off
1: Disable lift (input; low volts)
2: Speed limit (input; low volts)
3: Power reduction (input; low volts)
4: Disable lift (input; high volts)
5: Speed limit (input; high volts)
6: Power reduction (input; high volts)
48 V type: 5 to 16 km/h
0 to 99%
Same as #11
48 V type: 5 to 16 km/h
0 to 99%
Same as #11
48 V type: 5 to 16 km/h
0 to 99%
2 to 10 sec
1: Brake regen (accelerator must be
off)
2: Accelerator regen (also called
"auto reg")
1 to 5
1 to 5
0 to 40 sec
3 to 15 sec
48 V type: 5 to 16 km/h
0 to 40
1-23
MAIN CONTROLLER
Default
Range
value
0
10
0
0
10
0
0
10
0
5
2
4
3
20
5
12
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fb16ktFb20kt

Table of Contents