Mitsubishi FB18KT Service Manual page 31

Controller
Table of Contents

Advertisement

MAIN CONTROLLER
Setup Options (Group 1)
Option
Title of Option
#
Application
Pre-Sets
# 1
(Truck Operation
Mode)
# 2
Start Lift Speed
#3
Top Lift Speed
#4
Tilt Speed
#5
Auxiliary 1 Speed
#6
Auxiliary 2 Speed
#7
Top Travel Speed
Limit
#8
Acceleration Rate
#9
Traveling Power
#10
Service Indicator
(1) The service indicator shows the set value, not the current value. If the key switch is turned off without entering
data (without setting the switch to R), the current value is maintained. When data is entered, the current value is
replaced by the setting value on the display.
(2) The output power control function of the service indicator is the same as the output power control that is activated
when the battery voltage level drops.
(3) When the truck mode is selected, all data is replaced by the set values of the selected mode. When the set values
are changed, the truck mode indicator (A to E) flashes to notify that the settings are modified.
Description
There are 5 truck modes and each has 7
option values:
Top travel speed, Acceleration rate,
Traveling power, Regen adjustment, Start
lift speed, Top lift speed, Tilt speed.
For details, see page 1-8.
Lift speed when first lift switch is on.
Start lift speed cannot exceed Top lift speed.
Maximum lift speed when second lift
switch is on.
Tilt speed is prior to Lift speed in case that
the two levers are simultaneously operated.
Speed setting for attachment 1
(1: SLOW → 10: FAST)
Speed setting for attachment 2
(1: SLOW →10: FAST)
Maximum travel speed
Choice of acceleration rate
(1: SLOW, 2: MIDDLE, 3: FAST)
Choice of powering characteristic
(1: ECONOMY, 2: STANDARD,
3: POWERFUL)
This option sets the time which indicates
the maintenance time for the operator. The
amount of time set by this operation is
added to the truck's hourmeter at that time
and the total value is stored in memory as
the "maintenance time". When the truck's
hourmeter reaches maintenance time,
service indicator LED will turn on.
It will flash 20 hours before maintenance
time. You can reduce the truck power
when the LED is solid on by selection.
You can also setthe demo-mode, which
shows the ServiceIndicator function quickly.
(6 min aftersetting 0.1)
A, B, C, D, E
If any of these
option values are
changed, A thru E
will flash in order to
show that the truck
mode is not default
setting.
1 to 10
1 to 10
2 to 8
1 to 10
1 to 10
48 V type: 5 to16 km/h
1,2,3
1,2,3
100 to 500 hours in
50-hr. increments.
Attached "=" to the
value, the power
reduction function
will be effective.
Selecting 0.1 makes
the truck demo-
mode.
NOTE
1-22
Default Value
Range
48 V type
MC type
A
7
9
6
3
1
14
2
2
0
FC type
A
5
9
6
3
1
14
2
2
0