IRFLOW CONTROL MODE
Airfl ow Control mode offers air conditioning according to a location of
an occupant in a room detected by i-see Sensor.
1
Press
during COOL, DRY, HEAT or AUTO
mode to activate the AIRFLOW CONTROL mode. This
mode is only available when the i-see control mode is
effective.
2
Each press of
changes AIRFLOW CONTROL
in the following order:
(INDIRECT)
(DIRECT)
(INDIRECT) : An occupant will be less exposed to
direct airfl ow.
(DIRECT)
: Mainly the vicinity of an occupant will
be air-conditioned.
(EVEN)
: The unit learns the area where an
occupant spend most of the time,
and evens out the temperature of
that area.
• Horizontal and vertical airflow directions will be automatically selected.
• When more than a couple of people are in a room, the AIRFLOW
CONTROL mode may work less effectively.
• If you still feel uncomfortable with the air direction determined by the
INDIRECT mode, adjust the air direction manually.
3
Cancelling the i-see control mode automatically can-
cels the AIRFLOW CONTROL mode.
• The AIRFLOW CONTROL mode is also cancelled when the VANE or
WIDE VANE buttons is pressed.
En-9
(EVEN)
(OFF)
Page 8
A
BSENCE DETECTION
This function automatically changes the operation to No occupancy
energy-saving mode or No occupancy Auto-OFF mode when nobody
is in the room.
1
To activate this No occupancy energy-saving mode,
press
until
appears on the operation display of
the remote controller.
2
To activate this No occupancy Auto-OFF mode, press
until
appears on the operation display of the
remote controller.
3
Press
again to cancel the ABSENCE DETEC-
TION.
No
occupancy
detected
About
About 1 HR.
10 min.
Energy-
Normal
Saving energy
saving
mode
Normal
Auto-OFF
Saving energy
mode
• Even if the unit is turned OFF due to No occupancy Auto-OFF mode,
the display of the remote controller remains to indicate the unit is in
operation. Press
then press
tion.
• When OFF timer is set, a priority is given to OFF timer.
• No occupancy energy saving mode or No occupancy Auto-OFF mode
are not available during POWERFUL operation.
• The unit will not be turned off if no one is detected during normal
operation mode, even though No occupancy Auto-OFF mode is acti-
vated.
Cancel
Occupancy
detected
Normal
Saving more
Turn OFF
again to restart opera-