Performing Resistance Measurement and Continuity Test

C A U T I O N
1 Set the rotary switch to
2 Connect the red (+) and black
(–) test leads to the INPUT
terminals.
3 Probe the resistor (or shunt)
leads and read the display.
4 To perform continuity test,
press
to toggle the
audible continuity function on
or off.

Performing Temperature Measurements

WA R N I N G
1 Set the slide switch to the M
position to disable the output.
2 Set the rotary switch to mV.
3 Press and hold
than 1 second.
4 Plug the thermocouple probe
(with adapter) into the INPUT
terminals.
5 Touch the surface to be
measured with the
thermocouple probe and read
the display.
Disconnect circuit power and discharge all high-voltage capacitors before measuring
resistance to prevent possible damage to the instrument or the device under test.
.
• Before measuring the temperature of a circuit or device, disconnect its power.
• The bead type thermocouple probe is suitable for measuring temperature from
–40 °C to 204 °C in PTFE compatible environments. The probes may emit toxic
gas above this temperature range.
for more
For continuity test, the instrument will
beep if the resistance is less than the
values indicated below:
Measurement range
500.00 Ω
5.0000 kΩ
50.000 kΩ
500.00 kΩ
5.0000 MΩ
50.000 MΩ
Best practices:
• Do not bend the thermocouple
leads at sharp angles.
Repeated bending may break
the leads.
• Do not immerse the
thermocouple probe in any
liquid.
• Clean the surface to be
measured and make sure that
the probe is securely touching
the surface.
U1401A Quick Start Guide
Resistance
threshold
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ