Table of Contents

Advertisement

Quick Links

Stratus ftServer 3300, 5600, and 6600:

Site Planning Guide

Stratus Technologies
R553-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ftserver 3300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stratus ftserver 3300

  • Page 1: Site Planning Guide

    Stratus ftServer 3300, 5600, and 6600: Site Planning Guide Stratus Technologies R553-01...
  • Page 2 Stratus, the Stratus logo, ftServer, Continuum, Continuous Processing, StrataLINK, and StrataNET are registered trademarks of Stratus Technologies Bermuda, Ltd. The Stratus Technologies logo, the ftServer logo, Stratus 24 x 7 with design, The World’s Most Reliable Servers, The World’s Most Reliable Server Technologies, ActiveService, ftGateway, ftMemory, ftMessaging, ftStorage, Selectable Availability, XA/R, SQL/2000, and The Availability Company are trademarks of Stratus Technologies Bermuda, Ltd.
  • Page 3: Table Of Contents

    Site Planning for Fault-Tolerant Systems Site Planning Checklist System Documentation 2. Cabinet and Monitor Requirements Rack Requirements Cabinet Requirements for ftServer 3300, 5600, and 6600 Systems Additional Cabinet Requirements for ftServer 6600 Systems 2-2 Additional Cabinet Requirements for ftServer 3300 and 5600 Systems Monitor Requirements 3.
  • Page 4 APC UPS Models for Use with ftServer 6600 Systems APC UPS Models for Use with a Single ftServer 5600 System APC UPS Models for Use with Multiple ftServer 3300 and 5600 Systems APC UPS Models for Use with a Single ftServer 3300...
  • Page 5 Contents Appendix B. Specifications of Peripheral and Storage Components B-1 D540 Storage Enclosure Specifications V128 LCD Monitors Specifications V129 LCD Monitor Specifications V115 Keyboard Specifications AAP41105 PDU Specifications AAP41104 PDU Specifications B-10 AK470 KVM Switch Specifications B-12 AA000400 USB Floppy Disk Drive Specifications B-14 T521 and T522 Tape Drive Enclosure Specifications B-15...
  • Page 6 Figure A-6. Pedestal ftServer 3300 System - Rear View A-11 Figure A-7. Rack-Mountable ftServer 3300 System - Front View A-13 Figure A-8. Rack-Mountable ftServer 3300 System - Rear View A-14 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 7 Figures Figure B-1. D540 Storage Enclosure Figure B-2. V128 LCD Monitor Figure B-3. V129 LCD Monitor Figure B-4. AAP41105 PDU Figure B-5. AAP41104 PDU B-10 Figure B-6. AK470 KVM Switch B-12 Figure B-7. AA000400 USB Floppy Disk Drive B-14 Figure B-8. T521 and T522 Tape Drives B-15 Figure B-9.
  • Page 8 4-11 Table 4-16. ftServer 3300 System Power Cords: 100–127V and 50–60 Hz 4-11 Table 4-17. ftServer 3300 System Power Cords: 200–240V and 50 Hz 4-11 Table 4-18. ftServer 3300 System Power Cords: 200–240V and 50–60 Hz 4-12 Table 4-19. ftServer 3300 Systems: Power Cords to Connect Systems...
  • Page 9 APC Symmetra Models for PDUs and Multiple ftServer 5600 Systems Table 5-7. APC UPS Models for a Single Rack-Mountable ftServer 3300 System Table 5-8. APC UPS Models for a Single Pedestal ftServer 3300 System Table 6-1. Customer-Supplied Ethernet Cables Table 7-1. Component Power Requirements Table 7-2.
  • Page 10 Tables Table D-4. Noise Standards Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 11: Preface

    Autoloader, which can no longer be purchased. • Describes new uninterruptible power supply (UPS) models available from APC for use with a single ftServer 3300 system and for use with a single ftServer 5600 system. • Directs you to consider the requirements for the U574 Dual-Port Fiber Gigabit Ethernet Adapters and U575 Dual-Port Copper Gigabit Ethernet Adapters.
  • Page 12: Getting Help

    If you have a technical question about ftServer system hardware or software, try these online resources first: • Online support from Stratus Customer Service. You can find the latest technical information about an ftServer system through online product support at the Stratus Technical Support Web site: http://www.stratus.com/support/technics.htm...
  • Page 13 If you are unable to resolve your questions with the help available at these online sites, and the ftServer system is covered by a service agreement, please contact the Stratus Customer Assistance Center (CAC) or your authorized Stratus service representative.
  • Page 14 Preface Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 15: Welcome To Site Planning For Ftserver Systems

    Chapter 1 Welcome to Site Planning for ftServer Systems For an overview of the information you need to know and the tasks you need to perform to prepare a site for ftServer systems, see: • “Site Planning Overview” on page 1-2 •...
  • Page 16: Site Planning Overview

    • Purchasing an appropriate cabinet and monitor If you do not purchase a cabinet from Stratus, ensure that the cabinet you plan to use meets the system’s requirements. If you do not purchase a monitor from Stratus, make sure that the monitor you plan to use meets the system’s requirements.
  • Page 17: Site Planning For Fault-Tolerant Systems

    • ftServer systems can connect to the Stratus ActiveService Network (ASN). Connecting a system to the ASN allows the CAC or your authorized Stratus service representative to remotely diagnose, troubleshoot, and resolve problems online. To enable connectivity to the Stratus ActiveService Network (ASN), which allows...
  • Page 18: Site Planning Checklist

    Referring to the information in this document, answer the following questions: Planning for ActiveService Network Connectivity Will your system use ftServer Access Adapters to connect to the Stratus ASN? If your system uses ftServer Access Adapters, will you connect the adapters to a...
  • Page 19 U574 Dual-Port Fiber Gigabit Ethernet Adapter U575 Dual-Port Copper Gigabit Ethernet Adapter Will you supply your own monitor or will you use a monitor supplied by Stratus? Is the monitor rack-mountable or do you need to provide a table or desk? N O T E Use the USB keyboard and mouse supplied by Stratus.
  • Page 20 If you have any questions about the number and types of components, contact your Stratus account executive or distributor. Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 21: System Documentation

    System Documentation System Documentation When you receive your system, you will receive a printed copy of the Stratus ftServer 3300: Installation Guide (R528), Stratus ftServer 5600: Installation Guide (R539), or Stratus ftServer 6600: Installation Guide (R542). You can order additional copies of the system documentation set, consisting of these printed documents and the StrataDOC ftServer CD (part number R002FCDK).
  • Page 22 Use ftServer Management Console (ftSMC) to administer or troubleshoot an ftServer system Stratus ftServer Software Availability Monitor the performance of critical ftServer Manager User’s Guide (R007W) system components and the status of user applications Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 23 Notice page and the page numbers. – For online documentation, include the Help subject and topic title. This information will assist Stratus Publications in making any needed changes to the ftServer documentation. Your assistance is most appreciated.
  • Page 24 System Documentation 1-10 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 25: Cabinet And Monitor Requirements

    310-D standard. For ftServer 6600 systems, use a cabinet that is either 24U or 38U high. For ftServer 3300 and 5600 systems, use a cabinet that is either 25U or 42U high. Cabinet Requirements for ftServer 3300, 5600, and 6600 Systems Make sure that: •...
  • Page 26: Additional Cabinet Requirements For Ftserver 6600 Systems

    The distance between the front and rear vertical rails is between 25 in. and 30 in. (63.50 cm and 76.20 cm). • The vertical mounting rails accept M-5 cage nuts and mounting hardware. Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 27: Figure 2-1. Rail Clearance

    Rack Requirements Figure 2-1 shows the required rail clearance between the front vertical rails and the inside edge of an accessory leg. Figure 2-1. Rail Clearance 0.5-inch (1.27-cm) 0.5-inch minimum minimum msys182 Front vertical EIA rail Accessory leg Front of cabinet Cabinet and Monitor Requirements...
  • Page 28: Monitor Requirements

    Monitor Requirements Monitor Requirements If you are using a monitor that is not supplied by Stratus, make sure that: • The monitor accepts universal 100–240 VAC, 50–60 Hz power. • The VGA cable has a 15-pin D-sub connector. • The power cord for the monitor is long enough to reach the power source.
  • Page 29: Space Planning

    • “Planning for Cables” on page 3-2 Room Requirements If you have ordered an ftServer 6600 system already assembled in a Stratus cabinet, Table A-1, which provides the dimensions of the 24U and 38U cabinets. Otherwise, determine the dimensions of the cabinet in which you will install the system.
  • Page 30: Planning For Cables

    Make sure that any cables you plan to connect to the system are long enough to reach between the system and external components or connections. Table 3-1 lists the cables Stratus supplies and, for space planning, specifies the lengths of each cable. Table 3-1. Cables Supplied by Stratus Component Cable Description...
  • Page 31 Planning for Cables Table 3-1. Cables Supplied by Stratus (Continued) Component Cable Description Length Second tape drive in One SCSI-3 daisy chain cable with a 68-pin 3 ft (91.5 cm) a T522 tape drive SCSI-3 connector at each end enclosure, or second...
  • Page 32 Planning for Cables Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 33: Electrical (Ac) Power Planning

    • “Power Outlet Requirements” on page 4-5 • “Connecting a System Directly to Two Separate Power Sources” on page 4-7 • “Stratus-Supplied Power Cords” on page 4-9 Related Topics • Chapter 5, “UPS Planning” • Chapter 7, “ftServer Rack Configuration Planning”...
  • Page 34: Ac Power Service Requirements

    200–240V; 50 Hz Table 4-17. Rack-mountable system that 100–127V; 50 Hz For Japan, NEMA 5-15. does not connect to a PDU 200–240V; 50 Hz For other countries, see Table 4-17. Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 35: Table 4-4. Optional Components: Ac Power Service Requirements

    AC Power Service Requirements Table 4-3. ftServer 3300 Systems: AC Power Service Requirements (Continued) Nominal Input Voltage; Frequency Component Range Receptacle Rack-mountable system that 200–240V; 50–60 Hz Table 4-17 does not connect to a PDU High leakage current Table 4-18.
  • Page 36: Table 4-5. Worksheet For Determining A-Side Power Requirements

    (Extended) ftServer 6600 system 1300 ftServer 5600 system ftServer 3300 system D540 storage enclosure V128 1U LCD unit KVM switch T521 and T522 tape drive enclosure TOTAL A-SIDE POWER REQUIREMENTS Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 37: Power Outlet Requirements

    @ Power AC Power System Component Quantity (Watts) (Extended) ftServer 6600 system ftServer 5600 system ftServer 3300 system D540 storage enclosure TOTAL B-SIDE POWER REQUIREMENTS Table 4-7. Worksheet for Determining External Power Requirements @ Power AC Power System Component Quantity...
  • Page 38: Table 4-8. Worksheet: A-Side External Power Outlet Requirements - Pdus Used

    Table 4-10. Worksheet: A-Side External Power Outlet Requirements - No PDUs Component Quantity Outlets Subtotal Systems Monitors Storage enclosures T521 and T522 tape drives TOTAL NUMBER OF A-SIDE POWER OUTLETS Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 39: Connecting A System Directly To Two Separate Power Sources

    Connecting a System Directly to Two Separate Power Sources Table 4-11. Worksheet: B-Side External Power Outlet Requirements - No PDUs Component Quantity Outlets Subtotal Systems Monitors Storage enclosures T521 and T522 tape drives TOTAL NUMBER OF B-SIDE POWER OUTLETS Connecting a System Directly to Two Separate Power Sources If you do not connect the ftServer system or PDUs to a UPS, provide two AC power sources that are as electrically independent of each other as the installation site allows.
  • Page 40: Figure 4-2. Ftserver 5600 System Connected Directly To Ac Power

    AC power outlets Figure 4-3 shows the power connections for a pedestal ftServer 3300 system connected directly to two separate power sources. Figure 4-3. Pedestal ftServer 3300 Systems Connected Directly to AC Power s4u090 System power receptacles AC power outlet...
  • Page 41: Stratus-Supplied Power Cords

    5600 systems • ftServer 3300 systems • PDUs for ftServer 6600 systems • PDUs for ftServer 3300 and 5600 systems • Monitors, KVM switches, tape drives, and storage enclosures • External modems W A R N I N G Place all power cords out of the way of foot traffic.
  • Page 42: Ftserver 5600 System Power Cords

    Table 4-14. ftServer 5600 System Power Cords: 200 240V and 50 60 Hz Current Locale Plug Type Rating Length Marketing ID International NEMA L6-20 4.5m B50161-45M International IEC 309 4.5m B50153-45M 4-10 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 43: Ftserver 3300 System Power Cords

    3300 systems directly to an AC power source (not to a PDU or to a UPS). Table 4-19 lists the power cords that connect ftServer 3300 systems to APC Smart-UPS and APC Symmetra UPS models. –...
  • Page 44: Table 4-19. Ftserver 3300 Systems: Power Cords To Connect Systems To A Ups

    Marketing ID International NEMA L6-20 4.5m B50161-45M International IEC 309 4.5m B50153-45M Table 4-19. ftServer 3300 Systems: Power Cords to Connect Systems to a UPS Locale Voltage Rating Plug Types Marketing ID North America (Chicago) 120V IEC 320 C13 to B50104-15...
  • Page 45: Ftserver 6600 Systems: Pdu Power Cords

    Stratus-Supplied Power Cords ftServer 6600 Systems: PDU Power Cords The AA-P41105 PDU supplies power to ftServer 6600 systems. Table 4-20 describes the permanently attached power cords that supply power to the AA-P41105 PDU. These cords are 12 ft (3.7m) long.
  • Page 46: Ftserver 3300 And 5600 Systems: Pdu Power Cords

    AA-P41104 PDUs to the APC Smart-UPS and APC Symmetra UPS models. These power cords are supplied for ftServer 5600 systems. Table 4-22. ftServer 3300 and 5600 Systems: Power Cords to Connect PDUs to AC Power Current Locale...
  • Page 47: Power Cords For Monitors, Kvm Switches, And Tape Drives

    Stratus-Supplied Power Cords Power Cords for Monitors, KVM Switches, and Tape Drives Table 4-25 lists the specifications of the power cords that connect monitors, KVM switches, and tape drives directly to external AC power sources. Table 4-25. Monitor, KVM Switch, and Tape Drive Power Cords...
  • Page 48: Power Cords For External Modems

    6.5 ft (2.0m) AK-000377 CEE 7 VII Iceland, Sweden 250V/10A, plug type 6.5 ft (2.0m) AK-000378 CEE 7 VII India 250V/10A, plug type 6.5 ft (2.0m) AK-000379 CEE 7 VII 4-16 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 49 Stratus-Supplied Power Cords Table 4-26. External Modem Power Cords (Continued) Marketing Locale Description Length United Kingdom, Ireland 250V/10A, plug type 6.5 ft (2.0m) AK-000380 BS1363/A Italy 250V/10A, plug type 6.5 ft (2.0m) AK-000381 CEI 23-16 Netherlands 250V/10A, plug type 6.5 ft (2.0m)
  • Page 50 Stratus-Supplied Power Cords 4-18 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 51: Ups Planning

    Qualified APC UPS Models Stratus has qualified certain UPS models from American Power Conversion Corporation (APC) for use with ftServer systems. For a list the qualified UPS models for ftServer 3300, 5600, and 6600 systems, see one of the following: –...
  • Page 52: Table 5-1. Apc Symmetra Rm Models For North America For Ftserver 6600 Systems

    (2) NEMA L6-20R APC Symmetra 4kVA (1) NEMA L6-30R Scalable to 6kVA N+1 200V SYH6K6RMJ 6kVA; 4200W (2) NEMA L6-20R APC Symmetra 6kVA (1) NEMA L6-30R Scalable to 6kVA N+1 200V Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 53: Table 5-3. Apc Symmetra Rm International Models For Ftserver 6600 Systems

    † To convert an output connector panel to two IEC 309 30R connectors for 30A electrical connectivity to the PDU, obtain an SYPD9 output conversion kit from APC and an AW-B50172-01M interface cable from Stratus. Contact your distributor for availability of the interface cable. Table 5-4. APC Symmetra Tower Models for ftServer 6600 Systems Output Rating;...
  • Page 54: Table 5-5. Apc Smart-Ups Models For A Single Ftserver 5600 System

    Rest of the world Model SUA2200RMI2U 230V APC UPS Models for Use with Multiple ftServer 3300 and 5600 Systems Table 5-6 lists the APC Symmetra models to use when you connect PDUs or multiple ftServer 3300 or 5600 systems to the UPS.
  • Page 55: Apc Ups Models For Use With A Single Ftserver 3300 System

    Smart-UPS models to use with a single rack-mountable ftServer 3300 system. Table 5-8 lists the Smart-UPS models to use with a single pedestal ftServer 3300 system. Table 5-7. APC UPS Models for a Single Rack-Mountable ftServer 3300 System...
  • Page 56: Connecting The A-Side Pdu To A Ups

    UPS to the A-side PDU that supplies power to ftServer 6600 systems. N O T E A UPS is required if you use PDUs to supply power to ftServer 6600 systems. Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 57: Figure 5-1. Ftserver 6600 System: A-Side Pdu Connected To A Ups

    Connecting the A-Side PDU to a UPS Figure 5-1. ftServer 6600 System: A-Side PDU Connected to a UPS s10u052 A-side PDU A-side PDU power cord B-side PDU B-side PDU power cord UPS power cable A-side system power cables AC power outlet B-side system power cables AC power (mains) distribution circuit breaker...
  • Page 58: Figure 5-2. Ftserver 3300 And 5600 Systems: A-Side Pdu Connected To A Ups

    Figure 5-2 shows how to connect a UPS to the A-side PDU that supplies power to rack-mountable ftServer 3300 and 5600 systems. Figure 5-2. ftServer 3300 and 5600 Systems: A-Side PDU Connected to a UPS s6u104 A-side PDU A-side PDU power cord...
  • Page 59: Connecting Ftserver Systems Directly To A Ups

    Connecting ftServer Systems Directly to a UPS Connecting ftServer Systems Directly to a UPS The A-side power connector of ftServer systems can be connected directly to a UPS. Figure 5-3 shows how to connect a UPS directly to an ftServer 6600 system. Figure 5-3.
  • Page 60: Figure 5-4. Ftserver 3300 Or 5600 Systems: A-Side Power Directly Connected To A Ups

    Figure 5-4 shows how to connect a UPS directly to a rack-mountable ftServer 3300 or 5600 system. (An ftServer 3300 system is shown, but the connections are identical for both systems.) Figure 5-4. ftServer 3300 or 5600 Systems: A-Side Power Directly Connected to a UPS...
  • Page 61: Figure 5-5. Pedestal Ftserver 3300 Systems: A-Side Power Directly Connected To A Ups

    Connecting ftServer Systems Directly to a UPS Figure 5-5 shows how to connect a UPS to a pedestal ftServer 3300 system. Figure 5-5. Pedestal ftServer 3300 Systems: A-Side Power Directly Connected to a UPS s4u100 System power receptacles A-side system power cord...
  • Page 62 Connecting ftServer Systems Directly to a UPS 5-12 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 63: Network And Telephone Line Planning

    2. If you have a unique network requirement, contact Stratus Professional Services.For a list of available services, see http://www.stratus.com/services/ps/offerings.htm. 3. See the Stratus ftServer: PCI Adapter Guide (R461) for more information about the adapters Stratus supplies for ftServer systems. Network and Telephone Line Planning...
  • Page 64: Telephone Line Requirements

    In addition to Ethernet cables, plan to accommodate cables from any U486 Eight-Port Asynchronous PCI Adapters in the system. The U486 PCI adapters are paired and each adapter uses an eight-port fan-out cable with DB-25 connectors, which Stratus supplies. Telephone Line Requirements Generally, an ftServer system requires two telephone lines: •...
  • Page 65: Site Planning For Systems In An Ftgateway Group

    Make sure that only layer 1 and layer 2 devices separate the gateway and slave systems. During a connection, the gateway system assigns the slave system a temporary IP address from an IP address range reserved by Stratus and uses that address for all traffic.
  • Page 66 Site Planning for Systems in an ftGateway Group Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 67: Ftserver Rack Configuration Planning

    Systems and storage enclosures have two power receptacles. Correspondingly, two power distribution units (PDUs) provide power to the receptacles. Use of PDUs is optional unless you have a support agreement with Stratus. If so, use pairs of power distribution units (PDUs) to provide AC power to systems and components in a cabinet if six or more power cords would otherwise exit from the cabinet.
  • Page 68: Determining Pdu Power Requirements

    A-side PDU, complete the information in Table 7-2 to determine the current ftServer 3300 or 5600 systems and components will draw and whether you need a second pair of PDUs. To determine the A-side power usage...
  • Page 69: Table 7-2. A-Side Power Usage Calculation

    Using PDUs 3. In Table 7-2, for the first component in the table, write the same value in column 3 that you entered in column 2. For subsequent components, add the wattage of the new component to the subtotal in the previous row and write it in column 3. 4.
  • Page 70: Sample Power Usage Calculation

    A-side PDU. The A-side PDU can support four ftServer 3300 systems, three D540 storage enclosures, the V128 1U LCD unit, and the KVM switch. Adding the fourth D540 storage enclosure trips the 15A limit and would require a second pair of PDUs.
  • Page 71: Determining A-Side Pdu Power Outlets Usage

    Using PDUs Determining A-Side PDU Power Outlets Usage Make sure that ftServer 3300 or 5600 systems and components consume no more than the eight power outlets supported by the A-side PDU. To determine the number of A-side PDU power outlets used 1.
  • Page 72: Determining Rack Space Usage

    Determining Rack Space Usage Determining Rack Space Usage Make sure that the ftServer 3300 or 5600 systems and components fit into the vertical space available in the rack. To determine the vertical space used 1. In the Quantity column of Table 7-5, enter the number of each component.
  • Page 73: Supported Ftserver 6600 Cabinet Configurations

    Supported ftServer 6600 Cabinet Configurations Supported ftServer 6600 Cabinet Configurations The following figures show combinations of ftServer 6600 systems and optional components that are supported. N O T E S 1. The illustrations show where to place filler panels between components, but be sure to fill the rack above the components with filler panels and, if you do not use PDUs, fill the bottom 2U with filler panels.
  • Page 74: Figure 7-1. 24U And 38U Cabinet Configurations - Pdus Optional

    1U Filler Panel 10U System 10U System 1U Filler Panel or A-Side PDU 1U Filler Panel or A-Side PDU 1U Filler Panel or B-Side PDU 1U Filler Panel or B-Side PDU Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 75: Figure 7-2. 24U And 38U Cabinet Configurations - Pdus Optional

    Supported ftServer 6600 Cabinet Configurations Figure 7-2. 24U and 38U Cabinet Configurations – PDUs Optional (Continued) 1U LCD Unit 1U LCD Unit 1U Filler Panel 1U Filler Panel 1U Filler Panel 1U Filler Panel 1U Filler Panel 1U Filler Panel 1U Filler Panel 1U Filler Panel 1U Filler Panel...
  • Page 76: Figure 7-3. 24U And 38U Cabinet Configurations - Pdus Required

    3U Tape Drive 3U Tape Drive 1U Filler Panel 3U Storage Enclosure 2U Storage Enclosure 10U System 10U System 1U A-Side PDU 1U A-Side PDU 1U B-Side PDU 1U B-Side PDU 7-10 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 77: Figure 7-4. 24U And 38U Cabinet Configurations - Pdus Required

    Supported ftServer 6600 Cabinet Configurations Figure 7-4. 24U and 38U Cabinet Configurations – PDUs Required (Continued) 1U LCD Monitor 1U KVM Switch 3U Tape Drive 1U LCD Monitor 1U LCD Unit 1U Filler Panel 1U Filler Panel 3U Storage Enclosure 3U Storage Enclosure 10U System 3U Storage Enclosure...
  • Page 78: Figure 7-5. 38U Cabinet Configurations - Pdus Required

    3U Tape Drive 1U Filler Panel 1U Filler Panel 3U Tape Drive 3U Storage Enclosure 10U System 10U System 1U A-Side PDU 1U A-Side PDU 1U B-Side PDU 1U B-Side PDU 7-12 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 79: Figure 7-6. 38U Cabinet Configurations - Pdus Required

    Supported ftServer 6600 Cabinet Configurations Figure 7-6. 38U Cabinet Configurations – PDUs Required (Continued) 10U System 10U System 1U LCD Unit 1U LCD Monitor 1U KVM Switch 1U KVM Switch 1U Filler Panel 3U Tape Drive 1U Filler Panel 1U Filler Panel 1U Filler Panel 1U Filler Panel 1U Filler Panel...
  • Page 80: Figure 7-7. 38U Cabinet Configurations - Pdus Required

    Tape Drive Tape Drive 1U Filler Panel 3U Storage Enclosure 2U Storage Enclosure 10U System 10U System 1U A-Side PDU 1U A-Side PDU 1U B-Side PDU 1U B-Side PDU 7-14 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 81: Figure 7-8. 38U Cabinet Configurations - Pdus Required

    Supported ftServer 6600 Cabinet Configurations Figure 7-8. 38U Cabinet Configurations – PDUs Required (Continued) 3U Storage Enclosure 3U Storage Enclosure 3U Storage Enclosure 10U System 10U System 1U LCD Monitor 1U LCD Unit 1U KVM Switch 1U KVM Switch 3U Storage Enclosure 3U Tape Drive 3U Storage Enclosure 3U Storage Enclosure...
  • Page 82: Figure 7-9. 38U Cabinet Configurations - Pdus Required

    1U Filler Panel 1U Filler Panel 1U Filler Panel 3U Storage Enclosure 2U Storage Enclosure 10U System 10U System 1U A-Side PDU 1U A-Side PDU 1U B-Side PDU 1U B-Side PDU 7-16 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 83: Figure 7-10. 38U Cabinet Configuration - Pdus Required (Continued)

    Supported ftServer 6600 Cabinet Configurations Figure 7-10. 38U Cabinet Configuration – PDUs Required (Continued) 3U Storage Enclosure 3U Storage Enclosure 10U System 1U LCD Monitor 1U KVM Switch 3U Storage Enclosure 3U Storage Enclosure 10U System 1U A-Side PDU 1U B-Side PDU ftServer Rack Configuration Planning 7-17...
  • Page 84 Supported ftServer 6600 Cabinet Configurations 7-18 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 85: Appendix A. System Specifications

    “ftServer 6600 System Specifications” on page A-2 • “ftServer 5600 System Specifications” on page A-6 • “Pedestal ftServer 3300 System Specifications” on page A-10 • “Rack-Mountable ftServer 3300 System Specifications” on page A-13 N O T E The system temperature and humidity requirements,...
  • Page 86: Ftserver 6600 System Specifications

    24U and 38U shipping container and of the unpacked 24U and 38U cabinets. Table A-2 lists specifications for the ftServer 6600 system. Figure A-1. ftServer 6600 System - Front View s10u004 Core I/O enclosures CPU enclosures Expansion I/O enclosures Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 87: Figure A-2. Ftserver 6600 System - Rear View

    ftServer 6600 System Specifications Figure A-2. ftServer 6600 System - Rear View s10u150 SCSI port ftServer Access Adapter Ethernet port ftServer Access Adapter modem port 10/100/1000-Mbps Ethernet port 10/100-Mbps Ethernet port Serial ports USB ports VGA (monitor) port Power receptacles System Specifications...
  • Page 88: Table A-1. Ftserver 6600 Cabinet Dimensions

    Power Output wattage A-side power: 1300 W (AC) B-side power: 900 W (AC) Nominal input voltage; Frequency 200–240 volts AC; 50-60 Hz Physical Dimensions Height 17.75 in. (45 cm; 10U) Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 89 ftServer 6600 System Specifications Table A-2. ftServer 6600 System Specifications (Continued) Width 19 in. (48.26 cm) Depth (including ejectors) 30.9 in. (78.5 cm) Weight 310 lb (141 kg) Environmental Requirements ° ° ° ° Operating temperature F to 95 F (5 C to 35 For every 800 ft (243.8m) above 2,000 ft (609.6m), °...
  • Page 90: Ftserver 5600 System Specifications

    Table A-3 lists specifications for the ftServer 5600 system. Figure A-3. ftServer 5600 System - Front View s6u105 Core I/O enclosures CPU enclosures Expansion I/O enclosures Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 91: Figure A-4. Ftserver 5600 System - Rear View

    ftServer 5600 System Specifications Figure A-4. ftServer 5600 System - Rear View s6u089 SCSI port ftServer Access Adapter (optional) Ethernet port ftServer Access Adapter (optional) modem port 10/100/1000-Mbps Ethernet port 10/100-Mbps Ethernet port Serial ports USB ports VGA (monitor) port Power receptacles System Specifications...
  • Page 92: Table A-3. Ftserver 5600 System Specifications

    4500 BTUs per hour Features Processors One or two Intel Xeon processors in each CPU enclosure Memory Six dual data rate (DDR) inline memory module (DIMM) slots in each CPU enclosure Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 93 ftServer 5600 System Specifications Table A-3. ftServer 5600 System Specifications (Continued) Ports One 10/100-Mbps Ethernet port, one 10/100/1000-Mbps Ethernet port, and one external SCSI port on each core I/O enclosure Two AC power connectors, one VGA port, two serial ports, and two USB ports PCI slots One 32-bit 66MHz PCI slot for a video adapter or ftServer...
  • Page 94: Pedestal Ftserver 3300 System Specifications

    Pedestal ftServer 3300 System Specifications Pedestal ftServer 3300 System Specifications Figure A-5 shows the front of a pedestal ftServer 3300 system, its bezel pulled forward. Figure A-6 shows the rear of a pedestal ftServer 3300 system, specifying the locations of the connectors at the back of the system.
  • Page 95: Figure A-6. Pedestal Ftserver 3300 System - Rear View

    Pedestal ftServer 3300 System Specifications Figure A-6. Pedestal ftServer 3300 System - Rear View s4u102a SCSI port ftServer Access Adapter (optional) Ethernet port ftServer Access Adapter (optional) modem port 10/100/1000-Mbps Ethernet port 10/100-Mbps Ethernet port Power receptacles Serial ports USB ports...
  • Page 96: Table A-4. Pedestal Ftserver 3300 System Specifications

    One 10/100-Mbps Ethernet port, one 10/100/1000-Mbps Ethernet port, and one external SCSI port on each core I/O enclosure Two AC power connectors, one VGA port, two serial ports, and two USB ports A-12 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 97: Rack-Mountable Ftserver 3300 System Specifications

    Figure A-8 shows the rear of a rack-mountable ftServer 3300 system, specifying the locations of the connectors at the back of the system. Table A-5 lists the specifications for the rack-mountable ftServer 3300 system.
  • Page 98: Figure A-8. Rack-Mountable Ftserver 3300 System - Rear View

    A-side: 500W (AC) B-side: 500W (AC) Nominal input voltage Model dependent 100–127 volts AC; 50–60 Hz Model dependent 100–127, 200–240 volts AC; 50 Hz Model dependent 200–240 volts AC; 50–60 Hz A-14 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 99 Rack-Mountable ftServer 3300 System Specifications Table A-5. Rack-Mountable ftServer 3300 System Specifications (Continued) Physical Dimensions Height 7 in. (17.78 cm; 4U) Width 17.75 in. (45 cm) Depth 29.23 in. (75 cm) System weight 124 lb (56.25 kg) to 137 lb (62 kg) Environmental °...
  • Page 100 Rack-Mountable ftServer 3300 System Specifications A-16 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 101: Appendix B. Specifications Of Peripheral And Storage Components

    Appendix B Specifications of Peripheral and Storage Components For specifications of optional components, see: • “D540 Storage Enclosure Specifications” on page B-2 • “V128 LCD Monitors Specifications” on page B-4 • “V129 LCD Monitor Specifications” on page B-6 • “V115 Keyboard Specifications” on page B-7 •...
  • Page 102: D540 Storage Enclosure Specifications

    D540 storage enclosure. Figure B-1. D540 Storage Enclosure d540001 Disk drives Two advanced cooling and power supply (CAPS) modules Environmental services module (ESM) Two loop I/O modules Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 103: Table B-1. D540 Storage Enclosure Specifications

    D540 Storage Enclosure Specifications Table B-1. D540 Storage Enclosure Specifications Power Output wattage 300 W (AC) Nominal input voltage; Input frequency 100–240 volts AC; 50–63 Hz Physical Height 3.5 in. (8.9 cm; 2U) Width 17.6 in. (44.7 cm) Depth 19.5 in. (49.5 cm) Weight, fully configured 60 lb (27 kg) Disk drives...
  • Page 104: V128 Lcd Monitors Specifications

    V128 LCD monitor, which contains an integrated keyboard and trackpad. Table B-2 lists the specifications for the V128 LCD monitor. Figure B-2. V128 LCD Monitor Rear Front v128001 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 105: Table B-2. V128 Lcd Monitor Specifications

    V128 LCD Monitors Specifications Table B-2. V128 LCD Monitor Specifications Power Output wattage 21 W (AC) Input voltage 90-265 volts AC; 47-63 Hz Physical Height 1.75 in. (4.45 cm; 1U) Width 19 in. (48.3 cm) Depth 24 in. (61 cm) Environmental °...
  • Page 106: V129 Lcd Monitor Specifications

    Nominal input voltage; Frequency 90–265 volts AC; 47–63 Hz Physical Height 14.3 in. (36.2 cm) Width 13.6 in. (34.2 cm) Depth 7.3 in. (18.5 cm) Weight 5.7 lb (2.6 kg) Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 107: V115 Keyboard Specifications

    V115 Keyboard Specifications Table B-3. V129 LCD Monitor Specifications (Continued) Environmental ° ° ° ° Operating temperature F to 95 F (5 C to 35 ° ° ° Storage temperature F to +113°F (5 C to 45 Relative humidity during operation 30% to 80% (noncondensing) Relative humidity during storage 5% to 90% (noncondensing)
  • Page 108: Aap41105 Pdu Specifications

    AAP41105 power distribution unit (PDU) you can use to supply power to ftServer 6600 systems and optional rack-mountable components. Table B-5 lists the specifications for the AAP41105 PDU. Figure B-4. AAP41105 PDU pdu41150a Power cord (input) Power cord (output) Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 109: Table B-5. Aa-P41105 Pdu Specifications

    AAP41105 PDU Specifications Table B-5. AA-P41105 PDU Specifications Power Output wattage Nominal input voltage; Frequency 200–240 volts AC; 50–60 Hz Physical Dimensions Height 1.75 in. (4.45 cm) Width 19.1 in. (48.51 cm) Depth 6.75 in. (17.15 cm) Environmental ° ° °...
  • Page 110: Aap41104 Pdu Specifications

    AAP41104 PDU Specifications AAP41104 PDU Specifications Figure B-5 illustrates the AAP41104 PDU you can use to supply power to ftServer 3300 and 5600 systems and optional rack-mountable components. Table B-6 lists the specifications for the AAP41104 PDU. Figure B-5. AAP41104 PDU...
  • Page 111: Table B-6. Aap41104 Pdu Specifications

    AAP41104 PDU Specifications Table B-6. AAP41104 PDU Specifications Power Output wattage Nominal input voltage; 200–240 volts AC; 50–60 Hz Frequency range Physical Dimensions Height 1.75 in. (4.45 cm) Width 19.1 in. (48.51 cm) Depth 6.75 in. (17.15 cm) Environmental ° °...
  • Page 112: Ak470 Kvm Switch Specifications

    Physical Dimensions Width (front) 19 in. (48.26 cm) Width (rear) 16.75 in. (42.55 cm) Depth 10 in. (25.4 cm) Height 1.75 in. (4.45 cm; 1U) Weight 5 lb (2.27 kg) B-12 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 113 AK470 KVM Switch Specifications Table B-7. AK470 KVM Switch Specifications (Continued) Environmental ° ° ° ° Operating temperature F to 100.4 F (0 C to 38 0 to 2000 ft (0 to 609.6m) ° ° ° ° Storage temperature F to 140 F (-30 C to 60 Relative humidity during operation...
  • Page 114: Aa000400 Usb Floppy Disk Drive Specifications

    ° ° ° Storage temperature F to 140 F (-20 C to +60 Relative humidity during operation 20% to 80% (noncondensing) Relative humidity during storage 10% to 90% (noncondensing) B-14 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 115: T521 And T522 Tape Drive Enclosure Specifications

    T521 and T522 Tape Drive Enclosure Specifications T521 and T522 Tape Drive Enclosure Specifications Figure B-8 illustrates the T521 and T522 rack-mountable tape drive enclosures. The T521 enclosure contains a single tape drive and the T522 enclosure contains two tape drives.
  • Page 116: T511 Dds-4 Dat Tape Drive Specifications

    Nominal input voltage; Frequency 100–240 volts AC; 50–60 Hz Physical Height 3.7 in. (95 mm) Width 4.6 in. (116 mm) Depth 8.7 in. (220 mm) Weight 4.6 lb (2.1 kg) B-16 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 117: T513 Dlt 8000 Tape Drive Specifications

    T513 DLT 8000 Tape Drive Specifications T513 DLT 8000 Tape Drive Specifications Figure B-10 illustrates the T513 DLT 8000 tape drive. Table B-11 lists the specifications for the T513 tape drive. Figure B-10. T513 DLT 8000 Tape Drive mstr012a Table B-11. T513 Tape Drive Specifications Power Output wattage 28 W (AC) max.
  • Page 118: C719 External Modem Specifications

    Power Output wattage Nominal input voltage; Frequency range 100–240 volts AC; 50–60 Hz Physical Height 1.00 in. (2.5 cm) Width 4.25 in. (10.8 cm) Depth 5.60 in. (14.2 cm) B-18 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 119: Appendix C. Electrical Circuit And Wiring Information

    Appendix C Electrical Circuit and Wiring Information For electrical circuit and wiring information you need to provide to the contractor and/or facilities personnel responsible for wiring the power at the system installation site, see: • “Fault Protection Requirements” on page C-1 •...
  • Page 120: Figure C-1. Star Ground Example

    Figure C-1. Star Ground Example To monitor To ftServer system Earth reference ground (0V) Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 121: Circuit Wiring Diagrams

    Circuit Wiring Diagrams Circuit Wiring Diagrams The following circuit wiring diagrams show how the hot, ground, and/or neutral AC signals should be connected to the system’s power input plug: • Figure C-3 illustrates a single-phase 120V AC circuit connection (for ftServer 5600 and 3300 only).
  • Page 122: Figure C-3. Single-Phase 120V Ac Circuit Connection

    Figure C-3. Single-Phase 120V AC Circuit Connection Circuit A or B 120V G (PE) 15A Maximum Wall Power Cord G (PE) To power input A or B Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 123: Figure C-4. Single-Phase 240V Ac Circuit Connection

    Circuit Wiring Diagrams Figure C-4 shows a single-phase 240V AC circuit connection. Note that this application requires a single-pole circuit breaker. Figure C-4. Single-Phase 240V AC Circuit Connection Circuit A or B 240V G (PE) Single system: 20A maximum PDU: 30A maximum Wall Power Cord G (PE)
  • Page 124: Figure C-5. Split-Phase 120/240 Volts Ac Circuit Connection

    Figure C-5. Split-Phase 120/240 Volts AC Circuit Connection 240V Circuit A or B 120V 120V G (PE) Single system: 20A maximum PDU: 30A maximum Wall Power Cord G (PE) To power input A or B Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 125 Circuit Wiring Diagrams ∆ Figure C-6 shows a three-phase 208V AC, Y-, or -source circuit connection, which is a phase-to-neutral source connection. Note that the ftServer X input can be connected from L1, L2, or L3. This application requires a single-pole circuit breaker. ∆...
  • Page 126 -Source Circuit Connection, Phase-to-Phase 208V 120V 208V 120V Circuit A or B 120V G (PE) Single system: 20A maximum PDU: 30A maximum Wall Power Cord G (PE) To power input A or B Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 127: Electrical Power Connectors

    G (PE) To power input A or B Electrical Power Connectors Table C-1 describes the connectors that Stratus uses to connect the ftServer systems and its peripheral devices, such as tape drives, to AC power outlets. Electrical Circuit and Wiring Information...
  • Page 128: Table C-1. Connectors For Ac Power Outlets

    20A, 208/24 volts AC 2-pole, 3-wire NEMA 5-15 15A, 125 volts AC 2-pole, 3-wire NEMA L6-30 30A, 125/25 volts AC 2-pole, 3-wire CEE (7) VII 20A, 25 volts AC 2-pole, 3-wire C-10 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 129 Electrical Power Connectors Table C-1. Connectors for AC Power Outlets (Continued) Connector Configuration Rating Description ‡ BS 89 3 13A or 10A, 25 volts 2-pole, 3-wire CEI-23-16 16A, 25 volts AC 2-pole, 3-wire SI 32/1971 16A, 25 volts AC 2-pole, 3-wire IEC-309 16-20A, 200-24 volts 2-pole, 3-wire...
  • Page 130 3112-1993 † ftServer 6600 only ‡ ftServer 6600 only § ftServer 3300 and 5600 ¶ ftServer 3300 and 5600 †† ftServer 3300 and 5600 ‡‡ ftServer 3300 and 5600 C-12 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 131: Appendix D. Standards Compliance

    Electromagnetic compatibility (EMC) regulations. 3. All EMC emissions compliance tests are performed at a third-party certified test laboratory. You can obtain compliance reports for these tests from your Stratus account representative, who will contact the Product Compliance Group in the Stratus engineering organization.
  • Page 132: Table D-2. Immunity Standards

    ISO 9614-2 Acoustics. Determination of Sound Power European Union Levels of Noise Source using Sound Intensity ISO 7779 Measurements of Airborne Noise emitted by European Union Computers and Business Equipment Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 133 Standards Compliance VCCI Note BSMI Note Standards Compliance...
  • Page 134 Standards Compliance Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 135: Index

    B-14 USB, 3-2 ftGateway group VGA, 3-2 site planning for, 6-3 Y-style modem, 3-3 ftServer 3300 systems power service requirements, 4-2 getting assistance, 1-2 ftServer 5600 systems checklist for site planning, 1-2 power service requirements, 4-2 circuit connections, C-3...
  • Page 136 D540 storage enclosure, B-2 external modem, B-18 PDUs ftServer 3300 AAP41104 specifications, B-10 pedestal system, A-10 AAP41105 specifications, B-8 rack-mountable system, A-13 connecting to ftServer 3300 systems and ftServer 5600 system, A-6 Index-2 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)
  • Page 137 120/240V AC circuit V128 LCD monitors connection, C-6 power service requirements, 4-3 standards compliance, D-1 specifications, B-4 Stratus Customer Assistance Center. See CAC V129 LCD monitors system power cords, 4-15 power service requirements, 4-3, 4-5 specifications, B-6 VGA cables, 3-2...
  • Page 138 Index Index-4 Stratus ftServer 3300, 5600, and 6600: Site Planning Guide (R553)

This manual is also suitable for:

Ftserver 5600Ftserver 6600

Table of Contents