Installing an AA-E99100 RSN Console Server
Stratus Technologies
R007S-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AA-E99100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stratus AA-E99100

  • Page 1 Installing an AA-E99100 RSN Console Server Stratus Technologies R007S-01...
  • Page 2 Software described in Stratus documents (a) is the property of Stratus Technologies Bermuda, Ltd. or the third party, (b) is furnished only under license, and (c) may be copied or used only as expressly permitted under the terms of the license.
  • Page 3: Table Of Contents

    Contents Preface 1. Installing an AA-E99100 RSN Console Server Required Tools Components of the Shelf Kit and RSN Console Server Installing the RSN Console Server Shelf Preparing and Installing the RSN Console Server Contents...
  • Page 4 Figure 1-12. Ports on the Rear of the RSN Console Server 1-12 Figure 1-13. Securing the RSN Console Server 1-13 Figure 1-14. RSN Console Server Status LEDs 1-14 Figure 1-15. Adjusting the Shelf for the 2U Bezel 1-15 Installing an AA-E99100 RSN Console Server (R007S)
  • Page 5 Tables Table 1-1. Components of the Shelf Kit Table 1-2. Components of the AA-E99100 RSN Console Server Kit Tables...
  • Page 6 Tables Installing an AA-E99100 RSN Console Server (R007S)
  • Page 7: Preface

    Preface The Installing an AA-E99100 RSN Console Server (R007S) documents the installation of the AA-E99100 RSN console server. This document is intended for service personnel who service ftServer V Series systems in the field. Revision Information This document is a revision. This revision incorporates changes to reflect modifications to the RSN console tray.
  • Page 8  Online support from Stratus Customer Service. You can find the latest technical information about an ftServer system in the Stratus Customer Service Portal at the following Web site: http://www.stratus.com/go/support The Service Portal provides access to Knowledge Base articles for all Stratus product lines.
  • Page 9 Submit.  From any email client, send email to comments@stratus.com.  From the Stratus Customer Service Portal, log on to your account and create a new issue. Stratus welcomes any corrections and suggestions for improving this manual. Regulatory Notice The following document provides regulatory notices: https://stratadoc.stratus.com/compliance_info/Compliance_Information_for_Strat...
  • Page 10 Preface Installing an AA-E99100 RSN Console Server (R007S)
  • Page 11: Installing An Aa-E99100 Rsn Console Server

    Chapter 1 Installing an AA-E99100 RSN Console Server This manual describes how to install the AA-E99100 RSN console server using the shelf kit. Topics include the following:  “Required Tools” on page 1-1  “Components of the Shelf Kit and RSN Console Server” on page 1-2 ...
  • Page 12: Components Of The Shelf Kit And Rsn Console Server

    10-32 x 3/8” pan-head screw with cup washer (4) 10-32 x 5/8” pan-head screw with cup washer (8) ® Velcro strap (2) The AA-E99100 RSN console server consists of the components listed in Table 1-2. Table 1-2. Components of the AA-E99100 RSN Console Server Kit Component...
  • Page 13: Installing The Rsn Console Server Shelf

    2. Locate the hex standoffs and ball studs. Attach the ball stud to each standoff, and then thread them into each side of the shelf rail plate. See Figure 1-1. Figure 1-1. Inserting Ball Studs in Shelf Installing an AA-E99100 RSN Console Server...
  • Page 14: Figure 1-2. Inserting Velcro Straps In Shelf

    4. Install two 6-32 x 3/8" screws into the holes located near the front edge of the shelf, but leave the screw loose. See Figure 1-2. 5. On the front of the cabinet, remove the 1U bezels from U36, U37, and U38. Installing an AA-E99100 RSN Console Server (R007S)
  • Page 15: Figure 1-3. Hardware Placement In Front Of Rack

    6. Locate four of the 10-32 cage nuts. Install two in the left front rail and two in the right front rail at U36 (middle) and U37 (middle). See Figure 1-3. Figure 1-3. Hardware Placement in Front of Rack Installing an AA-E99100 RSN Console Server...
  • Page 16: Figure 1-4. Sliding Shelf Into Rack

    8. At the rear of the cabinet, mount the shelf support brackets on each rail, aligning the mounting holes in U36 (middle, top) with four 10-32 x 5/8” pan-head screws. Figure 1-5 Figure 1-6. Installing an AA-E99100 RSN Console Server (R007S)
  • Page 17: Figure 1-5. Mounting The Shelf Brackets On Each Rail

    Installing the RSN Console Server Shelf Figure 1-5. Mounting the Shelf Brackets on Each Rail Figure 1-6. Hardware Placement in Rear of Rack Installing an AA-E99100 RSN Console Server...
  • Page 18: Preparing And Installing The Rsn Console Server

    1. Unpack the RSN console server and place it on a flat surface with the heatsink fins facing down. 2. Locate the following additional components:  Bag containing M3x5 pan-head screws (4)  Wall-mount brackets  Power-supply module Installing an AA-E99100 RSN Console Server (R007S)
  • Page 19: Figure 1-8. Attaching The Wall-Mount Brackets To The Rsn Console Server

    Attach the wall-mount brackets along the edges, with the step surface up as shown in Figure 1-8, using four M3x5 pan-head screws. Figure 1-8. Attaching the Wall-Mount Brackets to the RSN Console Server Installing an AA-E99100 RSN Console Server...
  • Page 20: Figure 1-9. Installing The Power-Supply Module

    Secure the power-supply module to the shelf with the Velcro straps. See Figure 1-9 Figure 1-10. Figure 1-9. Installing the Power-Supply Module Figure 1-10. Securing the Power-Supply Module With Velcro 1-10 Installing an AA-E99100 RSN Console Server (R007S)
  • Page 21: Figure 1-11. Placing Rsn Console Server On Shelf

    8. Install the RSN console server by placing it on the shelf with the wall-mount brackets facing down. Position it diagonally so that the Ethernet and serial ports are on the left, facing forward. See Figure 1-11. Figure 1-11. Placing RSN Console Server on Shelf Installing an AA-E99100 RSN Console Server 1-11...
  • Page 22: Figure 1-12. Ports On The Rear Of The Rsn Console Server

    (labeled PWR), and secure the attached screws with a mini flat-blade screwdriver. N O T E The RSN console server will power on when the PSU cable is connected. Figure 1-12. Ports on the Rear of the RSN Console Server 1-12 Installing an AA-E99100 RSN Console Server (R007S)
  • Page 23: Figure 1-13. Securing The Rsn Console Server

    Slide the RSN console server to the right so that the 6-32 x 3/8” pan-head screws are against the left edge of the wall-mount bracket slot. c. Secure the two screws. Figure 1-13. Securing the RSN Console Server Installing an AA-E99100 RSN Console Server 1-13...
  • Page 24: Figure 1-14. Rsn Console Server Status Leds

    Preparing and Installing the RSN Console Server 11. Verify that the PWR LED (green LED shown in Figure 1-14) is lit. Figure 1-14. RSN Console Server Status LEDs 1-14 Installing an AA-E99100 RSN Console Server (R007S)
  • Page 25: Figure 1-15. Adjusting The Shelf For The 2U Bezel

    Tighten the screws. Figure 1-15. Adjusting the Shelf for the 2U Bezel 13. Attach the 2U bezel to the front of the shelf. 14. Install the 1U bezel in U38. Installing an AA-E99100 RSN Console Server 1-15...
  • Page 26 Preparing and Installing the RSN Console Server 1-16 Installing an AA-E99100 RSN Console Server (R007S)