Indesit CA55KUK Service Information

Indesit CA55KUK Service Information

Freestanding fridge freezer

Advertisement

Service
Information
© 2011 Reg. Office: Peterborough PE2 9JB Registered in London: 106725
Indesit Company UK Ltd
5407586 Issue 3 May 2012
INDESIT
FREESTANDING
FRIDGE
FREEZERS
Models
Covered
CA55UK
CA55KUK
CA55SUK
Energy Band A+ Models
CAA55UK
CAA55KUK
CAA55SUK
NCAA55UK
Comm.
Code
69937
74471
75733
77736
77739
77740
77735

Advertisement

Table of Contents
loading

Summary of Contents for Indesit CA55KUK

  • Page 1 FREEZERS Models Comm. Covered Code CA55UK 69937 CA55KUK 74471 CA55SUK 75733 Energy Band A+ Models CAA55UK 77736 CAA55KUK 77739 CAA55SUK 77740 Service NCAA55UK 77735 Information Indesit Company UK Ltd © 2011 Reg. Office: Peterborough PE2 9JB Registered in London: 106725...
  • Page 2: Health And Safety

    For the servicing of refrigeration products, containing Isobutane R600a refrigerant. These instructions are in addition to any other Company procedures already published. Published primarily for Indesit Company engineers working in the UK or Southern Ireland, for which these instructions are MANDATORY.
  • Page 3 Indesit Company HEALTH AND SAFETY 19. Working with a naked flame i.e. soldering or brazing is forbidden. Unless otherwise stated, pipework connections must only be made using the Lokring coupling system. 20. Electronic leak detectors with high voltage tips must NOT be used with any Isobutane (R600a).
  • Page 4: Table Of Contents

    Indesit Company INDEX Health and Safety........... 2 - 3 Index &...
  • Page 5: Introduction

    These models are two door 50/50 split freestanding fridge freezers. Model CA55UK was introduced during May 2010, manufactured by Indesit Company in Turkey. Model CA55KUK in black was introduced during July 2011 and model CA55SUK in silver was introduced during November 2010.
  • Page 6: Specifications

    Model Colour Commercial Code Introduction Date CA55UK White 69937 May 2010 Silver 75733 Nov. 2010 CA55SUK Black 74471 July 2011 CA55KUK White 77735 March 2012 NCAA55UK White 77736 Feb. 2012 CAA55UK Black 77739 Feb. 2012 CAA55KUK Silver 77740 May 2012...
  • Page 7 Indesit Company Energy Consumption - 2011 Regulation CAA55 NCAA55 kWh/year kWh/24 Hours 0.73 Energy Band Conservation Time - CA55 Models EU 1998 or Other Dedicated 17 hours Conservation Time - CA55 Models 2011 Regulation 14 hours Conservation Time - 2011 Regulation...
  • Page 8: Detailed View

    Indesit Company DETAILED VIEW TEMPERATURE REGULATING Removable Knob multipurpose SHELVES SHELVES GLASS COVER FRUIT and BOTTLE shelf VEGETABLE bins FREEZER and STORAGE compartment STORAGE compartments * Levelling FOOT FIXED FOOT (Hinge Side) • Varies by number and / or position...
  • Page 9: Component Details

    Indesit Company COMPONENT DETAILS Fast Freeze / Low Ambient Switch Fig. 1 This switch is mounted in the control box below the thermostat knob (see Fig. 1). Pressing ‘I’ enables the switch to the ‘ON’ position. Pressing ‘0’ enables the switch to the ‘OFF’ position.
  • Page 10: Servicing & Dismantling Instructions

    Indesit Company SERVICING & DISMANTLING INSTRUCTIONS Important Notes for Guidance: Before commencing any work refer to the Safety Notes and Safety Precaution at the beginning of this manual. Caution: When carrying out the following procedures care must be taken to protect the appliance and customers property, especially if the appliance is moved or laid down.
  • Page 11: Door Reversal Instructions

    Indesit Company DOOR REVERSAL Important Notes for Guidance: Before commencing any work refer to the Safety Notes at the beginning of this manual. Read the instructions below fully and refer to the diagrams before carrying out the door reversal. Caution: When carrying out the following procedures care must be taken to protect the appliance and the customers property, especially if the appliance is moved or laid down.
  • Page 12: Door Seal Replacement

    Indesit Company DOOR SEAL REPLACEMENT Various types of door seal are used for production and as replacements. See Figs. A, B and C showing seal profiles. Note also the liner profiles A5, A6 and B5, B6 below. Door seals as Fig. A, are retained by the liner which has 2 screws securing each corner.
  • Page 13: Theoretical Wiring Diagram

    Indesit Company THEORETICAL WIRING DIAGRAM COMPRESSOR CAPACITOR THERMOSTAT (if fitted) BLACK BROWN HEATER BROWN BROWN FAST FREEZE LIGHT LIGHT SWITCH SWITCH 5407275wd.pdf RFA52 BLUE BROWN Service Manual UK English 13 of 13...

This manual is also suitable for:

Ca55ukCaa55ukCa55sukCaa55kukCaa55sukNcaa55uk