Clean Air Filters; Cooling System; Acoustic Noise; Safety - Vivitek RP56HD21 Service Manual

Rear projection multi purpose display unit
Table of Contents

Advertisement

5.5. Clean Air Filters

Note:Clean air filters are replaceable without opening main projector cover.
5.6. Cooling system:
DVR5610 is a projection product which using UHP(ultra high pressure) lamp as light source, most of heat is
generated from the UHP lamp, this feature leads to following thermal consideration.
In DVR5610, forced convection is designed as the main cooling mechanism, fans are employeed as active
cooling devices to circulate flow. Regarding to flow path scheme, fresh air will be sucked into system naturally
and then cool the power module, DMD, electronics board and then lamp, hot air behind lamp wake will be
ventilated by an axial fan and be guideded by an air channel then exhaust to outside ambient. This thermal
system will provide about 15 CFM to circulate heat and keep low temperature inside DVR5610. For the most
important component,DMD, a high efficiency heat sink is designed to conduct heat from DMD and then
exchange heat with air that provided by a blower. This cooling design is applied to prevent DMD damage from
high temperature and make sure the lifetime of DMD.
5.7. Acoustic noise:
Acoustic noise measurements shall be conducted in accordance with ECMA 74 (5th edition).
The Equipment Under Test (EUT) is placed on a standard test table 0.5 m high, microphones centered on each
face of the EUT at a distance of 1.0 m from the EUT, 1.0 m above the floor. The free-field microphone shall
point at the EUT. The energy average A-weighted sound pressure level is reported.
the floor for the sound power test.
Test Procedure
The measurements shall be conducted in accordance with ECMA 74 with the addition for bystander positions
and declared in accordance with ECMA 109. Verification of the declared emission values shall be in
accordance with ECMA 109.
Maximum Levels
Steady State :

6. Safety

6.1. Interlocks

Interlocks
Lamp Module Cover

6.2. Labels

Labels
Lamp Removal Warning
Eye Damage Warning
Product label
Power Input label
Declared Sound Power Emission Level
(L
), bels
WAd
Type
Micro switch
Decal
Lens Cap Decal
Page25 of 79
Average Bystander Position Sound
Pressure Level (L
33
Description
Turns off all power when cover is removed
Warns not to remove lamp when hot
Warns not to look into the projection lens when the
lamp is on.
Includes model number and product serial number
Shows input voltage ranges and max current ratings.
The EUT is placed on
), dBA
pAm

Advertisement

Table of Contents
loading

Related Products for Vivitek RP56HD21

Table of Contents