Overall Audio Distorsion Factor Check; Overall Noise Level Check; Hifi Audio Frequency Response Check; Audio Pb Level Check - Sony SLV-SE850 Service Manual

Table of Contents

Advertisement

2-6-1-2. Overall Audio Distorsion Factor Check

[Adjustment purpose]
Confirm that the audio distorsion is within the specification.
Mode
Recording and playback (LP mode)
Signal
400Hz, –6.3dBs
Measurement Point
LINE1 A(L) OUT (CN500 3 pin) or
LINE1 A(R) OUT (CN500 1 pin)
Measuring Instrument
Distorsion meter
Specified Value
Less than 1.0%
Note: Perform "Audio Output Level Check" before this adjustment.
Switch setting:
INPUT SELECT ................................... L1
[Check method]
1)
Input a 400Hz, –6.3dBs signal to both L and R channels of
LINE 1 (A(L/R)IN) terminal.
2)
Record the signal in the LP mode.
3)
Playback the recorded section.
4)
Check that the 400Hz signal distorsion factor satisfies the
specified value.

2-6-1-3. Overall Noise Level Check

[Adjustment purpose]
Confirm that the noise level is within the specification.
Mode
Recording and playback (SP mode)
Signal
No signal :
Connect a shorting jumper between
A(L/R) IN (pins 2 and 6) and Au
GND (pin 4) of CN500
Measurement Point
LINE1 A(L) OUT (CN500 3 pin) or
LINE1 A(R) OUT (CN500 1 pin)
Measuring Instrument
Audio level meter
Specified Value
Less than –67.5dBs
Switch setting:
INPUT SELECT ................................... L1
[Check method]
1)
Connect A(L/R) IN (pins 2 and 6 of CN500) and Au
GND (pin 4 of CN500) with a shorting jumper.
2)
Record the signal in the SP mode.
3)
Playback the recorded section.
4)
Check that noise level is the specified value.

2-6-1-4. HiFi Audio Frequency Response Check

[Adjustment purpose]
Confirm that the frequency characteristics are within the
specification.
Mode
Signal
Measurement Point
Measuring Instrument
Specified Value
Note: Perform "Audio Output Level Check" of "Hi-Fi Audio System
Check" before this adjustment.
Switch setting:
INPUT SELECT ................................... L1
[Check method]
1)
Input a 30Hz, –26.3dBs signal to both L and R channels of
LINE 1 (A(L/R)IN) terminal.
2)
Record the signal in the SP/LP mode.
3)
Input a 400Hz, –26.3dBs signal to both L and R channels of
LINE 1 (A(L/R)IN) terminal.
4)
Record the signal in the SP/LP mode.
5)
Input a 20kHz, –26.3dBs signal to both L and R channels of
LINE 1 (A(L/R)IN) terminal.
6)
Record the signal in the SP/LP mode.
7)
Playback the recorded section.
8)
Press the AUDIO MONITOR button of the remote commander
and select the normal audio mode (STEREO indicator on the
display window turns off.).
9)
Check that the 20kHz, 400Hz signal level against to the 30Hz
signal level satisfies the specified value.

2-6-1-5. Audio PB Level Check

[Adjustment purpose]
Confirm that the Audio PB Level are within the specification.
Mode
Signal
Measurement Point
Measuring Instrument
Specified Value
[Check method]
1)
Check that the audio PB level the specified value.
6-5
Recording and playback
(SP/LP mode)
1: 30Hz, –26.3dBs
2: 400Hz, –26.3dBs
3: 20kHz, –26.3dBs
LINE1 A(L) OUT (CN500 3 pin) or
LINE1 A(R) OUT (CN500 1 pin)
Audio level meter
0 ± 3dB
Playback
Alignment tape : SP mode
HiFi audio position
LINE1 A(L) OUT (CN500 3 pin) or
LINE1 A(R) OUT (CN500 1 pin)
Audio level meter
–6.3 ± 2dBs

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents