Temperature Settings; Using Thermostat Keys; Installer Setup - Honeywell T8601D Installation Manual

Chronotherm iv deluxe zone thermostats
Hide thumbs Also See for T8601D:
Table of Contents

Advertisement

T8601D CHRONOTHERM

Using Thermostat Keys

The thermostat keys are used to:
• set current day and time,
• program times and setpoints for heating and cooling,
• temporarily override program temperatures,
• display present setting,
• configure Installer Setup,
• check Self-Test,
INCREASE TIME SETTING
OR SCROLL FORWARD
THROUGH INSTALLER SETUP
AND SYSTEM TEST
SET CURRENT
DAY AND TIME
RETURN TO
NORMAL
OPERATIONS
ENTER
INDEFINITE
OR TIMED
HOLD MODE
SET CURRENT OR
PROGRAM DAY
CHANGE BETWEEN
DAYLIGHT SAVINGS
AND STANDARD TIME
SETTINGS
System and Fan Settings
The system default setting is Heat and the fan default
setting is Auto. Use the System and Fan keys to change
the settings. See Fig. 7. The fan settings can be set for
each program period individually. The system selection is
for all the program periods.
System settings control thermostat operation as follows:
Heat: The thermostat controls the heating.
Off: Both the heating and cooling are off.
Cool: The thermostat controls the cooling.
Auto: The thermostat automatically changes between
heating and cooling operation, depending on the
indoor temperature.
Fan settings control the system fan as follows:
On: Fan operates continuously.
Auto: Fan operates with equipment.
69-1413—2
®
IV DELUXE ZONE THERMOSTATS
SET LEAVE TIMES
SET WAKE TIMES
AND SETPOINTS
AND SETPOINTS
Time
Set Current
Run
Day/Time
Program
Hold Temp
Day
Daylight
Copy
Time
COPY ONE PROGRAMMED
DAY TO ANOTHER DAY
Fig. 7. T8601D key locations and descriptions.
• display outdoor temperature (select models),
• set the system operation,
• set the fan operation.
NOTE: Always press the keys with your fingertip or
similar blunt tool. Sharp instruments like a pen
or pencil point can damage the keyboard.
See Fig. 7 for the location of the keys.
SET RETURN TIMES
AND SETPOINTS
Set Program
Wake
Leave
Return
Heat/Cool
System
Settings
DECREASE TIME SETTING OR
SCROLL BACKWARD THROUGH
INSTALLER SETUP AND SYSTEM TEST

Temperature Settings

Refer to Table 2 for the default program. If the daytime
energy savings period is not used, press the period key
(Leave or Return) until the time is blank. The fan setting
feature is available on select thermostat models. See
Owner's Guide, form number 69-1400, for complete
instructions on changing the program.
Table 3. Default Program Settings.
Period
Time
Wake
6:00 AM
Leave
8:00AM
Return 5:00 PM
Sleep
10:00 PM 62°F

INSTALLER SETUP

NOTE: For most applications, the thermostat factory-
settings will not need to be changed. Review
the factory settings in Table 2 and if no changes
are necessary, go to the Installer Self-Test
section.
4
INCREASE TEMPERATURE
SETTING OR SCROLL
FORWARD THROUGH
INSTALLER SETUP OPTIONS
DECREASE TEMPERATURE
SETTING OR SCROLL
BACKWARD THROUGH
INSTALLER SETUP OPTIONS
DISPLAY INFORMATION
SUCH AS PRESENT
SETTINGS AND OUTDOOR
TEMPERATURE
SET SLEEP TIMES
AND SETPOINTS
Sleep
SELECT FAN
Fan
OPERATION
SELECT SYSTEM
OPERATION
CHANGE BETWEEN
HEATING AND COOLING
SETPOINTS
Heat
Cool
Setpoint
Setpoint
70°F
78°F
(21°C)
(25.5°C)
62°F
85°F
(16.5°C)
(29.5°C)
70°F
78°F
(21°C)
(25.5°C)
82°F
(16.5°C)
(28°C)
M14624
Fan
Setting
Auto
Auto
Auto
Auto