Page 1
7000 Running Watts MODEL NUMBER Visit Our Website at: http://www.a-ipower.com SUA9000E Email Our Technical Support at: support@a-ipower.com FOR TECHNICAL QUESTIONS, PLEASE CALL 1-855-888-3598 SAVE THIS MANUAL This manual contains important information regarding safety, operation, maintnance and storage of this product. Before use, A-iPower Corp.
Page 2
Wattage Reference Guide Parts list and Diagram WARNING The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer or birth defects and other reproductive harm.
A-iPower. Please call our Customer Service at 1-855-888-3598 for starting, operating and servicing procedures. We also strongly recommend you to instruct any other users who may operate the generator in an emergency. A-iPower SECTION 1 SAFETY RULES Failure to follow...
Page 5
please call our Customer Service at 1-855-888-3598.
SECTION 2 SET UP INSTALL THE WHEEL KIT 2- 9.5 in wheel 2 -axle pin Wheel kit 2- pin 4- washer 1- support leg Support Leg 2-flange bolt (M8x16) 2- nut (M8) 1- engine oil 1.0 Quart 1- DC charge cable Other 1- spark torch 1- extension bar...
Page 7
Control Panel - See "Power Panel" section on Page 8. We are always working to improve our products. Therefore, final product may vary from images shown. A-iPower reserves the right to change features, specifications without notice for further improvements of products.
CONTROL PANEL 1. Hour Meter - Monitor run time and schedule maintenance intervals 2. Low Oil Alarm - Alarm when low oil is detected 3. Circuit Breaker - The circuit breadker protects the generator against electrical overloads. The rating of the breaker and the load it protects are marked near the breaker.
4.4 WATTAGE REFERENCE GUIDE Fuel Valve START Turn Fuel Valve to ON position.
Page 11
starts Push the switch to “START” position, hold in start position until generator start. Caution: to prolong the life of starter components, DO NOT hold for more than 10 seconds. Pause and retry as necessary. After generator starts, release switch and it will return to the “ON” position automatically.
Volts x Amps = Watts The “WATTAGE REFERENCE GUIDE”on Page 10 helps to determine how many items the generator can operate at one time. turn Engine DO NOT overload Generator Capacity HIGH ALTITUDE OPERATION At high altitudes over 3,000 feet, the engine carburetor and any other parts that control the fuel-air ratio will be affected, which will decrease performance, increase fuel consumption and...
CHANGING ENGINE OIL engine If running this unit under dirty or dusty conditions, or in extremely hot weather, to change the oil more often. AIR FILTER MAINTENANCE SPARK PLUG MAINTENANCE...
Page 16
Problem Possible Causes Probable Solutions FUEL RELATED: Engine will not start FUEL RELATED: 1. No fuel in tank or fuel valve is in “OFF” position. 1. Fill fuel tank with fresh 87+ octane unleaded stabilizer-treated gasoline and turn fuel valve to “ON”...
Page 17
Problem Possible Causes Probable Solutions Engine misfires 1. Spark plug cap loose. 1. Check wire connections. 2. Incorrect spark plug gap or 2. Re-gap or replace spark plug. damaged spark plug. 3. Defective spark plug cap. 3. Replace spark plug cap. 4.
Page 18
Model Number SUA9000E Starting Watts 9000 Running Watts 7000 AC Load 120/240V Frequency 60Hz Running VAC Amperage 29.0A Generator Phase Single IP Class Power Factor ONE - 120V AC 30A L5-30R Receptacle FOUR - 120V 20A NEMA 5-20R GFCI Outlet...
SECTION 11 PARTS LIST AND DIAGRAM GENERAL PARTS LIST Part Part Discription Discription Nut, Flange Hexagon Blot Nut, Flange Bolt,Flange Shock Absorbing Mount Motor Bracket Washer, Plain Wiring Borad Assy Wheel Assy Bolt,Flange Axle Carbon Brush Clip, Dowel Pin Motor Cover, Rear Positive Charging Wire Washer, Plain Negative Charging Wire...
ENGINE PARTS LIST Part Part Discription Discription Bolt Bearing Cylinder Head Cover Assy Crankshaft Assy Exhaust Pipe Gasket, Crankcase Cover Gasket, Cylinder Cap Dowel Pin Bolt,Flange Crankcase Cover Assy Air Deflector Bolt,Flange Regulating Nut, Rockshaft Oil Seal Rockshaft Bearing Rocker Arm Dipstick Bolt, Rockshaft Bolt,Flange...