Model SRK28CD-S (Indoor unit)
SRC28CD-S (Outdoor unit)
Item
(1)
Cooling capacity
Power source
Cooling input
Running current (Cooling)
Inrush current
COP
sound level
Cooling
Noise level
Power level
Exterior dimensions
Height × Width × Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
(3)
Refrigerant
Refrigerant oil
Deice control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Size × Core number
Connection wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
The piping length is 7.5m.
(2) The operation data are applied to the 220/230/240V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 15 m connecting piping.
(Purging is not required even in the short piping.)
Model
W
kW
A
A
dB
mm
kg
kW
kg
R
W
(Cooling)
CMM
Compressor: Overheat protection, overcurrent protection, Serial signal error protection, Indoor fan
motor error protection, Frost protection
mm (in)
Item
Indoor air temperature
DB
27ºC
SRK28CD-S
1 Phase, 220/230/240V, 50Hz
Cooling: 3.21
Hi 39, Me 33, Lo 30
55
250 × 815 × 249
Cool white
9.0
Louver fins & inner grooved tubing
Capillary tubes + Electronic expansion valve
R410A 0.9 (Pre-Charged up to the piping length of 15m)
0.35 (RB68A)
Tangential fan × 1
14
8.0
Polypropylene net (washable) × 2
Wireless-Remote controller
MC. Thermostat
RUN (Green), TIMER (Yellow), HI POWER (Green), ECONO (Orange)
Liquid line: φ6.35 (1/4") Gas line: φ9.52 (3/8")
Flare connecting
Liquid line: 0.4 m
Gas line : 0.33 m
Necessary (Both sides)
Connectable
2.5 m (3 cores with Earth)
× 4 cores (Including earth cable)
1.5 mm
2
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
WB
DB
19ºC
35ºC
6
-
-
SRC28CD-S
2550
0.79
3.9/3.7/3.5
17.2
46
60
540 × 720 × 290
Stucco white
32
5PS102DAB [Rotary type] × 1
0.7
Line starting
MC control
Propeller fan × 1
15
30
Cushion rubber (for compressor)
WB
24ºC
Standards
ISO-T1, JIS C9612