ascon ACK 20E Manual

ascon ACK 20E Manual

Ack-e series; a5ck-e series ceiling cassette split systems

Advertisement

Models:
ACK/A5CK 20E/ER
ACK/A5CK 25E/ER
ACK/A5CK 28E/ER
ACK/A5CK 40E/ER
ACK/A5CK 50E/ER
Ceiling Cassette Split Systems
ACK - E - 2009

Advertisement

Table of Contents

Troubleshooting

loading
Need help?

Need help?

Do you have a question about the ACK 20E and is the answer not in the manual?

Questions and answers

Summary of Contents for ascon ACK 20E

  • Page 1 Models: ACK/A5CK 20E/ER ACK/A5CK 25E/ER ACK/A5CK 28E/ER ACK/A5CK 40E/ER ACK/A5CK 50E/ER Ceiling Cassette Split Systems ACK - E - 2009...
  • Page 2: Table Of Contents

    ACK-E-2009 Table of Contents Table of Contents Nomenclature........................1 Indoor Unit ........................1 Outdoor Unit ........................2 Product Line-Up ......................3 Features..........................10 Application Information ....................11 Operating Range ......................11 Refrigerant Circuit Diagram ..................12 Controller ........................17 Installation Guideline ....................20 Sound Data ........................33 Sound Pressure Level ....................33 NC Curve ........................34 Engineering &...
  • Page 3: Nomenclature

    Nomenclature ACK-E-2009 Nomenclature Indoor Brand : Acson Refrigerant “ “ : Omitted if R22 : R407C : R410A Model Name : Ceiling Cassette Capacity Index : 20,000 Btu/h Chassis : E Series Model Type “ “ : Omitted if cooling only : Heatpump...
  • Page 4: Outdoor Unit

    ACK-E-2009 Nomenclature Outdoor Brand : Acson Refrigerant “ “ : Omitted if R22 : R407C : R410A Model Name : Single Split Condensing Unit Capacity Index : 20,000 Btu/h Chassis : E Series Model Type “ “ : Omitted if cooling only : Heatpump...
  • Page 5: Indoor Unit

    Product Line-Up ACK-E-2009 Product Line-Up Indoor Unit ACK-E Series Classifi cation Model ACOBA ACOBA ACOBA ACOBA ACOBA 20ER ACOBA 25ER ACOBA 28ER ACOBA 40ER ACOBA 50ER ACOBA...
  • Page 6 ACK-E-2009 Product Line-Up Indoor Unit A5CK-E Series Classifi cation Model ACOBA ACOBA ACOBA ACOBA ACOBA 20ER ACOBA 25ER ACOBA 28ER ACOBA 40ER ACOBA 50ER ACOBA...
  • Page 7 Product Line-Up ACK-E-2009 Indoor Unit ACK Panel Product Line Up Classifi cation Model PLCKE-NG18 PLCKER-NG18...
  • Page 8 ACK-E-2009 Product Line-Up Outdoor Unit Classifi cation Model ACPOD ACPID ACPHB ACPBD ACPOD ACPID ACPBD ACPHB ACPSD ACHOB ACHIB ACHBB AFGE AFGG AFGE AFGG FFGE FFGF FFGG FFGL AUCOA FUDOA FFGN FFGP FFGQ FFGT FUDOA...
  • Page 9 Product Line-Up ACK-E-2009 Outdoor Unit Classifi cation Model ACPOD 20CR ACPID ACPHB ACPOD 25CR ACPID ACPHB ACHOB 28CR ACHIB AFFB 35CR AFFD AFFB AFFD 40CR FFFB FFFD FFFF 50CR FFFG...
  • Page 10 ACK-E-2009 Product Line-Up Outdoor Unit A5LC Classifi cation Model ACPIC ACPOC FCPOC ACPIC ACPOC FCPOC ACPOA ACPIA FCPOA ACCOB ACCGB FCCOB FCCGB FCCGB FCCOB ACCOB ACCGB FCCOB FCCGB...
  • Page 11 Product Line-Up ACK-E-2009 Outdoor Unit A5LC Classifi cation Model ACPIC 20CR ACPOC FCPOC ACPIC 25CR ACPOC FCPOC ACPOA 28CR ACPIA FCPOA ACCOB ACCGB 35CR FCCOB FCCGB ACCGB ACCOB 40CR FCCOB FCCGB FCCOB 50CR FCCGB...
  • Page 12: Features

    ACK-E-2009 Features Features Improved Sound Level The new ACK-E series is equipped with a newly-developed turbo fan, which has improved the sound pressure level of the unit signifi cantly. Lower Height Model To ease installation, the overall height of the ACK-E series has been greatly reduces. (350mm for ACK-E, 290mm for ACK 20-28E/ER, 325mm for ACK 40-50E/ER).
  • Page 13: Application Information

    Application Information ACK-E-2009 Application Information Operating Range Ensure the operating temperature is in allowable range. Cooling only Standard point Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. Indoor temp.
  • Page 14: Refrigerant Circuit Diagram

    ACK-E-2009 Application Information Refrigerant Circuit Diagram Model: ACK 20E - ALC 20C A5CK 25E - A5LC 25C A5CK 20E - A5LC 20C 70034 095231 Model: ACK 25E - ALC 25C A5CK 28E - A5LC 28C 70034 049972...
  • Page 15 Application Information ACK-E-2009 Model: ACK 28E - ALC 28C 70034 049972 Model: ACK 40E - ALC 35/40C ACK 50E - ALC 50C 70034 049181...
  • Page 16 ACK-E-2009 Application Information Model: A5CK 40E - A5LC 35/40C A5CK 50E - A5LC 50C 70034 097007 Model: ACK/A5CK 20ER - ALC/A5LC 20CR A5CK 25ER - A5LC 25CR 70034 095238...
  • Page 17 Application Information ACK-E-2009 Model: ACK 28ER - ALC 28CR 70034 049972 Model: ACK/A5CK 28ER - ALC/A5LC 28CR 70034 049181...
  • Page 18 ACK-E-2009 Application Information Model: ACK 30ER - ALC 30CR ACK 40ER - ALC 35/40CR ACK 50ER - ALC 50CR 70034 095246 Model: A5CK 40ER - A5LC 35/40CR A5CK 50ER - A5LC 50CR 08014 085116...
  • Page 19: Controller

    Application Information ACK-E-2009 Controller Operation Guide Transmission Source Operating Mode • The source where the signal will be transmitted. • Press the MODE button to select the type of operating mode. Signal Transmission Indication • For cooling only unit, the available modes are: COOL ( ), •...
  • Page 20 ACK-E-2009 Application Information Operating State and Fault Table Wireless Remote Control Cooling : LED Indicator Light Display Heatpump : LED Indicator Light Display POWER TIMER SLEEP POWER TIMER HEAT Operation / Faulty Indication HEAT POWER TIMER SLEEP Cool Mode Time On Sleep Mode On Heat Mode Auto Mode - Cool...
  • Page 21: Water Pump

    Application Information ACK-E-2009 Water Pump The water pump will on if compressor is on during cooling cycle. The pump will remain on for at least 5 minutes after the compressor is off. During mode change from cooling to non-cooling mode, the pump will on for minimum 5 minutes. During defrost cycle, the pump will on and will on for another 5 minutes once the defrost cycle is terminated.
  • Page 22: Installation Guideline

    ACK-E-2009 Application Information Installation Guideline Caution • Sharp edges and coil surfaces are potential injury hazard. Avoid from contact with them. (1) Installation Of Indoor Unit Preliminary Site Survey • Electrical supply and installation is to confi rm to local authority’s (e.g. National Electrical Board) codes and regulations.
  • Page 23: Drain Piping Work

    Application Information ACK-E-2009 Unit Hanging Ceiling Board 35.0mm ACK-E • Confi rm the pitch of the hanging rod is 770mm x 622mm sharp. • Hold the unit and hand it on the hanging rod with the nut and washer. • Adjust the unit height to 35.0mm between the indoor unit bottom surface and the ceiling surface.
  • Page 24: Panel Installation

    ACK-E-2009 Application Information Panel Installation • The front panel can only be fi tted in one direction, follow the piping direction. (Follow piping arrow sticker on the front panel). • Be sure to remove the installation template before installing the front panel. •...
  • Page 25 Application Information ACK-E-2009 Short Duct Specifi cation • The indoor unit is provided with air discharge and air intake “knock-out” hole for duct connection. However the connection of the short duct for air discharge is possible on only one side. •...
  • Page 26 ACK-E-2009 Application Information (2) Installation Of Outdoor Unit As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum cooling capacity, the location selected for outdoor unit should fulfi ll the following requirements: • Install the condensing (outdoor) unit in a way such that hot air distributed by the outdoor condensing unit cannot be drawn in again (as in the case of short circuit of hot discharge air).
  • Page 27 Application Information ACK-E-2009 (3) Refrigerant Piping Maximum Piping Length and Maximum Number of Bends When the pipe length becomes too long, both the capacity and reliability drop. As the number of bends increases, system piping resistance to the refrigerant fl ow increases, thus lowering the cooling capacity, and as the result the compressor may become defective.
  • Page 28: Electrical Connections

    ACK-E-2009 Application Information Piping Connection To The Units • Align the centre of the piping and tighten the fl are nut suffi ciently with fi ngers. • Finally tighten the fl are nut with torque wrench unit the wrench clicks. •...
  • Page 29 Application Information ACK-E-2009 (5) Vacuuming and Charging The pre-charged outdoor unit does not need any vacuuming or charging. However once it is connected, the connecting pipe line and the indoor unit need to be vacuumed before releasing the R22/R407C/R410A from the outdoor unit.
  • Page 30 ACK-E-2009 Application Information (6) Additional Charge • The refrigerant charge has already charged into the outdoor unit. For the piping length of 7.6m, additional refrigerant charge after vacuuming is not necessary. • When the piping length is more than 7.6m, please use the table below (unit in gram). Model 20C/CR 38 / 53...
  • Page 31 Application Information ACK-E-2009 The additional refrigerant charge amount recommended is a guideline for longer piping application. The actual charge required may be different from the guideline due to different application and variation in site conditions. Diagram shows typical charging method: (Mclecular-Sieve Type) Note : R407C - Fix filter dryer R22 - Nil...
  • Page 32 ACK-E-2009 Application Information Special Precautions When Dealing With Refrigerant R410A Unit (1) What is New Refrigerant R410A? R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential.
  • Page 33 Application Information ACK-E-2009 (d) When charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This is to ensure that only the original composition of R410A is being delivered into the system. The liquid composition can be different from the vapor composition. Invert cylinder Dip-pipe without dip-pipe...
  • Page 34 ACK-E-2009 Application Information (7) Overall Checking • Ensure the following, in particular: 1. The unit is mounted solidly and rigid in position. 2. Piping and connections are leak proof after charging. 3. Proper wiring has been done. • Drainage check – pour some water into drain pan. •...
  • Page 35: Sound Data

    1/1 Octave A-Weighted Sound Pressure (dBA), ref 20μPa Overall Noise Model A (dBA) Criteria 125 Hz 250 Hz 500 Hz 1k Hz 2k Hz 4k Hz 8k Hz High Medium ACK 20E/ER Super Low High Medium ACK 25E/ER Super Low High Medium ACK 28E/ER...
  • Page 36: Nc Curve

    ACK-E-2009 Sound Data ACK 20E/ER NC Curve NC70 NC65 NC60 NC55 NC50 NC45 NC40 NC35 Super High Fan NC30 High Fan NC25 Medium Fan NC20 Low Fan 1000 2000 4000 8000 Octave-band frequency (Hz) ACK 25E/ER NC Curve NC70 NC65...
  • Page 37 Sound Data ACK-E-2009 ACK 28E/ER NC Curve NC70 NC65 NC60 NC55 NC50 NC45 Super High Fan NC40 NC35 High Fan NC30 Medium Fan NC25 Low Fan NC20 1000 2000 4000 8000 Octave-band frequency (Hz) ACK 40E/ER NC Curve NC70 NC65 NC60 NC55 NC50...
  • Page 38 ACK-E-2009 Sound Data ACK 50E/ER NC Curve NC70 NC65 NC60 NC55 NC50 NC45 NC40 Super High Fan NC35 High Fan NC30 Medium Fan NC25 Low Fan NC20 1000 2000 4000 8000 Octave-band frequency (Hz)
  • Page 39: Engineering & Physical Data

    Engineering & Physical Data ACK-E-2009 Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT ACK 20E ACK 25E MODEL OUTDOOR UNIT ALC 20C ALC 25C Btu/h 19500 25000 NOMINAL CAPACITY 5715 7327 NOMINAL TOTAL INPUT POWER 1960...
  • Page 40 ACK-E-2009 Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT ACK 28E MODEL OUTDOOR UNIT ALC 28C Btu/h 27000 NOMINAL CAPACITY 7913 NOMINAL TOTAL INPUT POWER 2720 NOMINAL RUNNING CURRENT 12.3 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 2.91 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE)
  • Page 41 Engineering & Physical Data ACK-E-2009 General Data - Cooling Only (R22) INDOOR UNIT ACK 40E ACK 40E MODEL OUTDOOR UNIT ALC 35C ALC 40C Btu/h 35000 39000 <40000> NOMINAL CAPACITY - 1Ø <3Ø> 10258 11430 <11723> NOMINAL TOTAL INPUT POWER - 1Ø <3Ø> 3010 3450 <3260>...
  • Page 42 ACK-E-2009 Engineering & Physical Data General Data - Cooling Only (R22) INDOOR UNIT ACK 50E MODEL OUTDOOR UNIT ALC 50C Btu/h 47500 NOMINAL CAPACITY 13921 NOMINAL TOTAL INPUT POWER 4600 NOMINAL RUNNING CURRENT POWER SOURCE V/Ph/Hz 380 - 415 / 3 / 50 3.03 REFRIGERANT TYPE REFRIGERANT CONTROL (EXPANSION DEVICE)
  • Page 43 Engineering & Physical Data ACK-E-2009 General Data - Heat Pump (R22) INDOOR UNIT ACK 20ER ACK 25ER MODEL OUTDOOR UNIT ALC 20CR ALC 25CR Btu/h 19500 25000 NOMINAL COOLING CAPACITY 5715 7327 Btu/h 19500 25000 NOMINAL HEATING CAPACITY 5715 7327 NOMINAL TOTAL INPUT POWER (COOLING) 1960 2540...
  • Page 44 ACK-E-2009 Engineering & Physical Data General Data - Heat Pump (R22) INDOOR UNIT ACK 28ER MODEL OUTDOOR UNIT ALC 28CR Btu/h 27000 NOMINAL COOLING CAPACITY 7913 Btu/h 28000 NOMINAL HEATING CAPACITY 8206 NOMINAL TOTAL INPUT POWER (COOLING) 2720 NOMINAL TOTAL INPUT POWER (HEATING) 2350 NOMINAL RUNNING CURRENT (COOLING) 12.3...
  • Page 45 Engineering & Physical Data ACK-E-2009 General Data - Heat Pump (R22) INDOOR UNIT ACK 40ER ACK 40ER MODEL OUTDOOR UNIT ALC 35CR ALC 40CR Btu/h 35000 39000 / <40000> NOMINAL COOLING CAPACITY - 1Ø <3Ø> 10258 11430 / <11723> Btu/h 35000 41000 / <42000>...
  • Page 46 ACK-E-2009 Engineering & Physical Data General Data - Heat Pump (R22) INDOOR UNIT ACK 50ER MODEL OUTDOOR UNIT ALC 50CR Btu/h 47500 NOMINAL COOLING CAPACITY 13921 Btu/h 48000 NOMINAL HEATING CAPACITY 14068 NOMINAL TOTAL INPUT POWER (COOLING) 4600 NOMINAL TOTAL INPUT POWER (HEATING) 4070 NOMINAL RUNNING CURRENT (COOLING) NOMINAL RUNNING CURRENT (HEATING)
  • Page 47 Engineering & Physical Data ACK-E-2009 General Data - Cooling Only (R410A) INDOOR UNIT A5CK 20E A5CK 25E MODEL OUTDOOR UNIT A5LC 20C A5LC 25C Btu/h 18300 22200 NOMINAL CAPACITY 5363 6506 NOMINAL TOTAL INPUT POWER 1740 1940 NOMINAL RUNNING CURRENT POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50...
  • Page 48 ACK-E-2009 Engineering & Physical Data General Data - Cooling Only (R410A) INDOOR UNIT A5CK 28E MODEL OUTDOOR UNIT A5LC 28C Btu/h 27000 NOMINAL CAPACITY 7913 NOMINAL TOTAL INPUT POWER 2790 NOMINAL RUNNING CURRENT 13.1 POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 2.84 REFRIGERANT TYPE R410A...
  • Page 49 Engineering & Physical Data ACK-E-2009 General Data - Cooling Only (R410A) INDOOR UNIT A5CK 40E A5CK 40E MODEL OUTDOOR UNIT A5LC 35C A5LC 40C Btu/h 29200 / <31000> 39000 / <39000> NOMINAL COOLING CAPACITY - 1Ø / <3Ø> 8558 / <9086> 11430 / <11430>...
  • Page 50 ACK-E-2009 Engineering & Physical Data General Data - Cooling Only (R410A) INDOOR UNIT A5CK 50E MODEL OUTDOOR UNIT A5LC 50C Btu/h 43000 NOMINAL CAPACITY 12603 NOMINAL TOTAL INPUT POWER 4390 NOMINAL RUNNING CURRENT POWER SOURCE V/Ph/Hz 380 - 415 / 3 / 50 2.87 REFRIGERANT TYPE R410A...
  • Page 51 Engineering & Physical Data ACK-E-2009 General Data - Heat Pump (R410A) INDOOR UNIT A5CK 20ER A5CK 25ER MODEL OUTDOOR UNIT A5LC 20CR A5LC 25CR Btu/h 18300 22200 NOMINAL COOLING CAPACITY 5363 6506 Btu/h 17700 20500 NOMINAL HEATING CAPACITY 5188 6008 NOMINAL TOTAL INPUT POWER (COOLING) 1740 1940...
  • Page 52 ACK-E-2009 Engineering & Physical Data General Data - Heat Pump (R410A) INDOOR UNIT A5CK 28ER MODEL OUTDOOR UNIT A5LC 28CR Btu/h 27000 NOMINAL COOLING CAPACITY 7913 Btu/h 28000 NOMINAL HEATING CAPACITY 8206 NOMINAL TOTAL INPUT POWER (COOLING) 2790 NOMINAL TOTAL INPUT POWER (HEATING) 2320 NOMINAL RUNNING CURRENT (COOLING) 13.1...
  • Page 53 Engineering & Physical Data ACK-E-2009 General Data - Heat Pump (R410A) INDOOR UNIT A5CK 40ER A5CK 40ER MODEL OUTDOOR UNIT A5LC 35CR A5LC 40CR Btu/h 29200 / <31000> 39000 / <39000> NOMINAL COOLING CAPACITY - 1Ø / <3Ø> 8558 / <9086> 11430 / <11430>...
  • Page 54 ACK-E-2009 Engineering & Physical Data General Data - Heat Pump (R410A) INDOOR UNIT A5CK 50ER MODEL OUTDOOR UNIT A5LC 50CR Btu/h 43000 NOMINAL COOLING CAPACITY 12603 Btu/h 47300 NOMINAL HEATING CAPACITY 13863 NOMINAL TOTAL INPUT POWER (COOLING) 4390 NOMINAL TOTAL INPUT POWER (HEATING) 4010 NOMINAL RUNNING CURRENT (COOLING) NOMINAL RUNNING CURRENT (HEATING)
  • Page 55: Component Data

    Engineering & Physical Data ACK-E-2009 Component Data - Cooling Only (R22) INDOOR UNIT ACK 20E ACK 25E MODEL OUTDOOR UNIT ALC 20C ALC 25C TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT...
  • Page 56 ACK-E-2009 Engineering & Physical Data Component Data - Cooling Only (R22) INDOOR UNIT ACK 28E MODEL OUTDOOR UNIT ALC 28C TYPE BLOWER WHEEL QUANTITY MATERIAL ASG 10% INDOOR FAN DRIVE DIRECT DIAMETER mm/in 462 / 18.18 LENGTH mm/in 171 / 6.13 TYPE INDUCTION INDOOR FAN MOTOR...
  • Page 57 Engineering & Physical Data ACK-E-2009 Component Data - Cooling Only (R22) INDOOR UNIT ACK 40E ACK 40E MODEL OUTDOOR UNIT ALC 35C ALC 40C TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 462 / 18.18...
  • Page 58 ACK-E-2009 Engineering & Physical Data Component Data - Cooling Only (R22) INDOOR UNIT ACK 50E MODEL OUTDOOR UNIT ALC 50C TYPE BLOWER WHEEL QUANTITY MATERIAL ASG 10% INDOOR FAN DRIVE DIRECT DIAMETER mm/in 462 / 18.18 LENGTH mm/in 171 / 6.13 TYPE INDUCTION INDOOR FAN MOTOR...
  • Page 59 Engineering & Physical Data ACK-E-2009 Component Data - Heat Pump (R22) INDOOR UNIT ACK 20ER ACK 25ER MODEL OUTDOOR UNIT ALC 20CR ALC 25CR TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 462 / 18.18...
  • Page 60 ACK-E-2009 Engineering & Physical Data Component Data - Heat Pump (R22) INDOOR UNIT ACK 28ER ACK 28ER MODEL OUTDOOR UNIT ALC 28CR ALC 28CR TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 462 / 18.18...
  • Page 61 Engineering & Physical Data ACK-E-2009 Component Data - Heat Pump (R22) INDOOR UNIT ACK 40ER ACK 40ER MODEL OUTDOOR UNIT ALC 35CR ALC 40CR TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 462 / 18.18...
  • Page 62 ACK-E-2009 Engineering & Physical Data Component Data - Heat Pump (R22) INDOOR UNIT ACK 50ER MODEL OUTDOOR UNIT ALC 50CR TYPE BLOWER WHEEL QUANTITY MATERIAL ASG 10% INDOOR FAN DRIVE DIRECT DIAMETER mm/in 462 / 18.18 LENGTH mm/in 171 / 6.13 TYPE INDUCTION INDOOR FAN MOTOR...
  • Page 63 Engineering & Physical Data ACK-E-2009 Component Data - Cooling Only (R410A) INDOOR UNIT A5CK 20E A5CK 25E MODEL OUTDOOR UNIT A5LC 20C A5LC 25C TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 462 / 18.18...
  • Page 64 ACK-E-2009 Engineering & Physical Data Component Data - Cooling Only (R410A) INDOOR UNIT A5CK 28E MODEL OUTDOOR UNIT A5LC 28C TYPE BLOWER WHEEL QUANTITY MATERIAL ASG 10% INDOOR FAN DRIVE DIRECT DIAMETER mm/in 462 / 18.18 LENGTH mm/in 171 / 6.13 TYPE INDUCTION INDOOR FAN MOTOR...
  • Page 65 Engineering & Physical Data ACK-E-2009 Component Data - Cooling Only (R410A) INDOOR UNIT A5CK 40E A5CK 40E MODEL OUTDOOR UNIT A5LC 35C A5LC 40C TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 462 / 18.18...
  • Page 66 ACK-E-2009 Engineering & Physical Data Component Data - Cooling Only (R410A) INDOOR UNIT A5CK 50E MODEL OUTDOOR UNIT A5LC 50C TYPE BLOWER WHEEL QUANTITY MATERIAL ASG 10% INDOOR FAN DRIVE DIRECT DIAMETER mm/in 462 / 18.18 LENGTH mm/in 171 / 6.13 TYPE INDUCTION INDOOR FAN MOTOR...
  • Page 67 Engineering & Physical Data ACK-E-2009 Component Data - Heat Pump (R410A) INDOOR UNIT A5CK 20ER A5CK 25ER MODEL OUTDOOR UNIT A5LC 20CR A5LC 25CR TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 462 / 18.18...
  • Page 68 ACK-E-2009 Engineering & Physical Data Component Data - Heat Pump (R410A) INDOOR UNIT A5CK 28ER A5CK 28ER MODEL OUTDOOR UNIT A5LC 28CR A5LC 28CR TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 462 / 18.18...
  • Page 69 Engineering & Physical Data ACK-E-2009 Component Data - Heat Pump (R410A) INDOOR UNIT A5CK 40ER A5CK 40ER MODEL OUTDOOR UNIT A5LC 35CR A5LC 40CR TYPE BLOWER WHEEL BLOWER WHEEL QUANTITY MATERIAL ASG 10% ASG 10% INDOOR FAN DRIVE DIRECT DIRECT DIAMETER mm/in 462 / 18.18...
  • Page 70 ACK-E-2009 Engineering & Physical Data Component Data - Heat Pump (R410A) INDOOR UNIT A5CK 50ER MODEL OUTDOOR UNIT A5LC 50CR TYPE BLOWER WHEEL QUANTITY MATERIAL ASG 10% INDOOR FAN DRIVE DIRECT DIAMETER mm/in 462 / 18.18 LENGTH mm/in 171 / 6.13 TYPE INDUCTION INDOOR FAN MOTOR...
  • Page 71: Safety Devices

    Engineering & Physical Data ACK-E-2009 Safety Devices - MCK-E Series INDOOR UNIT ACK 20E MODEL OUTDOOR UNIT ALC 20C TYPE HIGH PRESSURE SWITCH OPEN kPa / psi CLOSE kPa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH OPEN kPa / psi...
  • Page 72 ACK-E-2009 Engineering & Physical Data Safety Devices - MCK-E Series INDOOR UNIT ACK 50E MODEL OUTDOOR UNIT ALC 50C TYPE HIGH PRESSURE SWITCH OPEN kPa / psi 2937 / 426 CLOSE kPa / psi 2413 / 350 TYPE SAFETY DEVICE LOW PRESSURE SWITCH OPEN kPa / psi...
  • Page 73 Engineering & Physical Data ACK-E-2009 Safety Devices - MCK-E Series INDOOR UNIT ACK 40ER ACK 40ER MODEL OUTDOOR UNIT ALC 35CR ALC 40CR TYPE HIGH PRESSURE SWITCH OPEN kPa / psi 2937 / 426 2937 / 426 CLOSE kPa / psi 2413 / 350 2413 / 350 TYPE...
  • Page 74 ACK-E-2009 Engineering & Physical Data Safety Devices - M5CK-E Series INDOOR UNIT A5CK 20E A5CK 25E MODEL OUTDOOR UNIT A5LC 20C A5LC 25C TYPE HIGH PRESSURE SWITCH OPEN kPa / psi CLOSE kPa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH OPEN kPa / psi CLOSE...
  • Page 75 Engineering & Physical Data ACK-E-2009 Safety Devices - M5CK-E Series INDOOR UNIT A5CK 20ER A5CK 25ER MODEL OUTDOOR UNIT A5LC 20CR A5LC 25CR TYPE HIGH PRESSURE SWITCH OPEN kPa / psi CLOSE kPa / psi TYPE SAFETY DEVICE LOW PRESSURE SWITCH OPEN kPa / psi CLOSE...
  • Page 76: Performance Data

    Interpolation and Extrapolation method can be used to get the total capacity, TC and sensible capacity, SC at those temperatures which are not stated out in the table. Example: Model: ACK 20E – ALC 20C Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB...
  • Page 77: Calculation Steps

    Performance Data ACK-E-2009 Details: Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 24°C DB, 15°C WB Outdoor Condition: 35°C DB Outdoor DB, ˚C Indoor DB˚C Indoor WB˚C TC (kW) SC (kW) ........... 5.419 3.94 5.495 3.71 Total capacity, TC ⇒...
  • Page 78 ACK-E-2009 Performance Data Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 35°C DB Outdoor DB, ˚C Indoor DB˚C Indoor WB˚C TC (kW) SC (kW) 5.343 2.925 ........... 5.343 4.17 Total capacity, TC ⇒...
  • Page 79 Performance Data ACK-E-2009 Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB Outdoor DB, ˚C Indoor DB˚C Indoor WB˚C TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) 3.295 3.859...
  • Page 80: Performance Table

    ACK-E-2009 Performance Data Cooling Only (R22) Model: ACK 20E - ALC 20C Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 6.886 4.269 6.371 3.821 5.857 3.373 5.343 2.925 4.828 2.477 4.211...
  • Page 81 Performance Data ACK-E-2009 Model: ACK 28E - ALC 28C Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 9.173 5.692 5.095 7.827 4.498 7.154 3.901 6.481 3.303 5.673 2.587 9.177 5.051 8.542 4.561 7.907...
  • Page 82 ACK-E-2009 Performance Data Model: ACK 40E - ALC 35C (1 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 11.539 7.064 10.8 6.384 10.061 5.704 9.322 5.024 8.582 4.343 7.696 3.527 11.555 6.316...
  • Page 83 Performance Data ACK-E-2009 Model: ACK 40E - ALC 40C (3 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 12.723 7.926 11.899 7.223 11.074 6.52 10.25 5.817 9.425 5.114 8.436 4.271 12.924 7.053...
  • Page 84 ACK-E-2009 Performance Data Heat Pump (R22) Model: ACK 20ER - ALC 20CR Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 6.886 4.269 6.371 3.821 5.857 3.373 5.343 2.925 4.828 2.477 4.211 1.939 6.843...
  • Page 85 Performance Data ACK-E-2009 Model: ACK 25ER - ALC 25CR Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 8.301 5.301 4.867 7.299 4.433 6.798 3.998 6.297 3.564 5.695 3.043 8.436 4.744 7.955 4.391 7.474...
  • Page 86 ACK-E-2009 Performance Data Model: ACK 28ER - ALC 28CR Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 9.173 5.692 5.095 7.827 4.498 7.154 3.901 6.481 3.303 5.673 2.587 9.177 5.051 8.542 4.561 7.907...
  • Page 87 Performance Data ACK-E-2009 Model: ACK 40ER - ALC 35CR (1 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 11.539 7.064 10.8 6.384 10.061 5.704 9.322 5.024 8.582 4.343 7.696 3.527 11.555 6.316...
  • Page 88 ACK-E-2009 Performance Data Model: ACK 40ER - ALC 40CR (1 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 12.509 7.883 11.704 7.151 10.899 6.419 10.094 5.687 9.289 4.955 8.323 4.077 12.673 7.135...
  • Page 89 Performance Data ACK-E-2009 Model: ACK 40ER - ALC 40CR (3 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 12.723 7.926 11.899 7.223 11.074 6.52 10.25 5.817 9.425 5.114 8.436 4.271 12.924 7.053...
  • Page 90 ACK-E-2009 Performance Data Model: ACK 50ER - ALC 50CR Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 14.59 9.052 13.731 12.872 7.547 12.013 6.794 11.154 6.041 10.124 5.138 14.78 8.071 13.973 7.468 13.167...
  • Page 91 Performance Data ACK-E-2009 Cooling Only (R410A) Model: A5CK 20E - A5LC 20C Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 6.043 3.869 5.628 3.454 5.236 3.062 4.844 2.67 4.452 2.277 3.981 1.807 6.16...
  • Page 92 ACK-E-2009 Performance Data Model: A5CK 28E - A5LC 28C Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 8.526 5.482 7.952 4.908 7.412 4.369 6.873 3.83 6.334 3.291 5.686 2.644 8.751 5.113 8.186 4.599...
  • Page 93 Performance Data ACK-E-2009 Model: A5CK 40E - A5LC 35C (1 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 9.941 6.288 9.131 5.477 8.325 4.672 7.52 3.867 6.715 3.061 5.748 2.095 10.082 5.815...
  • Page 94 ACK-E-2009 Performance Data Model: A5CK 40E - A5LC 40C (1 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 11.252 7.087 10.56 6.396 9.743 5.752 8.927 5.108 8.111 4.464 7.132 3.691 11.666 6.645...
  • Page 95 Performance Data ACK-E-2009 Model: A5CK 50E - A5LC 50C Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 13.022 8.478 12.216 7.672 11.482 6.938 10.747 6.203 10.013 5.469 9.131 4.587 13.447 7.897 12.686 7.192...
  • Page 96 ACK-E-2009 Performance Data Heat Pump (R410A) Model: A5CK 20ER - A5LC 20CR Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 6.043 3.869 5.628 3.454 5.236 3.062 4.844 2.67 4.452 2.277 3.981 1.807 6.16...
  • Page 97 Performance Data ACK-E-2009 Model: A5CK 25ER - A5LC 25CR Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 6.553 4.344 6.133 3.924 5.745 3.536 5.357 3.148 4.969 2.76 4.504 2.295 6.781 4.071 6.35 3.697...
  • Page 98 ACK-E-2009 Performance Data Model: A5CK 28ER - A5LC 28CR Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 8.526 5.482 7.952 4.908 7.412 4.369 6.873 3.83 6.334 3.291 5.686 2.644 8.751 5.113 8.186 4.599...
  • Page 99 Performance Data ACK-E-2009 Model: A5CK 40ER - A5LC 35CR (1 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 9.941 6.288 9.131 5.477 8.325 4.672 7.52 3.867 6.715 3.061 5.748 2.095 10.082 5.815...
  • Page 100 ACK-E-2009 Performance Data Model: A5CK 40ER - A5LC 35CR (3 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 9.319 5.853 8.669 5.203 8.05 4.584 7.432 3.966 6.813 3.347 6.071 2.605 9.616 5.458...
  • Page 101 Performance Data ACK-E-2009 Model: A5CK 40ER - A5LC 40CR (1 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 11.252 7.087 10.56 6.396 9.743 5.752 8.927 5.108 8.111 4.464 7.132 3.691 11.666 6.645...
  • Page 102 ACK-E-2009 Performance Data Model: A5CK 40ER - A5LC 40CR (3 Phase) Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 11.313 7.381 10.646 6.707 9.862 6.086 9.079 5.466 8.295 4.846 7.356 4.102 11.692 6.931...
  • Page 103 Performance Data ACK-E-2009 Model: A5CK 50ER - A5LC 50CR Cooling Mode Outdoor DB°C DB°C WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 13.022 8.478 12.216 7.672 11.482 6.938 10.747 6.203 10.013 5.469 9.131 4.587 13.447 7.897 12.686 7.192...
  • Page 104: Outline And Dimension

    ACK-E-2009 Outline and Dimension Outline and Dimension Indoor Unit Model: ACK/A5CK 20/25/28E/ER All dimensions are in mm/(in) Model CK20/25/28E (32.3) (32.3) (13.8) (11.4) (2.4) (39.0) (39.0) (24.7) (24.7) (23.9) (23.9) CK40/50E (32.3) (32.3) (12.8) (12.8) (2.4) (39.0) (39.0) (24.7) (24.7) (23.9) (23.9) Outdoor Unit...
  • Page 105 ACK-E-2009 Outline and Dimension Model: ALC/A5LC 35/40/50C/CR All dimensions are in mm/(in)
  • Page 106: Electrical Data

    ACK-E-2009 Electrical Data Electrical Data Electrical Data - Cooling Only (R22) INDOOR UNIT ACK 20E ACK 25E MODEL OUTDOOR UNIT ALC 20C ALC 25C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50...
  • Page 107 Electrical Data ACK-E-2009 Electrical Data - Cooling Only (R22) INDOOR UNIT ACK 40E ACK 40E MODEL OUTDOOR UNIT ALC 35C ALC 40C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT...
  • Page 108: Electrical Data

    ACK-E-2009 Electrical Data Electrical Data - Heat Pump (R22) INDOOR UNIT ACK 20ER ACK 25ER MODEL OUTDOOR UNIT ALC 20CR ALC 25CR INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT...
  • Page 109 Electrical Data ACK-E-2009 Electrical Data - Heat Pump (R22) INDOOR UNIT ACK 40ER ACK 40ER MODEL OUTDOOR UNIT ALC 35CR ALC 40CR INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT...
  • Page 110 ACK-E-2009 Electrical Data Electrical Data - Cooling Only (R410A) INDOOR UNIT A5CK 20E A5CK 25E MODEL OUTDOOR UNIT A5LC 20C A5LC 25C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT...
  • Page 111 Electrical Data ACK-E-2009 Electrical Data - Cooling Only (R410A) INDOOR UNIT A5CK 40E A5CK 40E MODEL OUTDOOR UNIT A5LC 35C A5LC 40C INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT...
  • Page 112 ACK-E-2009 Electrical Data Electrical Data - Heat Pump (R410A) INDOOR UNIT A5CK 20ER A5CK 25ER MODEL OUTDOOR UNIT A5LC 20CR A5LC 25CR INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT...
  • Page 113 Electrical Data ACK-E-2009 Electrical Data - Heat Pump (R410A) INDOOR UNIT A5CK 40ER A5CK 40ER MODEL OUTDOOR UNIT A5LC 35CR A5LC 40CR INSULATION GRADE CLASS B CLASS B POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT...
  • Page 114: Wiring Diagram

    ACK-E-2009 Wiring Diagram Wiring Diagram Cooling Only Indoor Unit Outdoor Unit Model: ACK/A5CK 20/25/28E Model: ALC/A5LC 20/25/28C 08024 105303...
  • Page 115 Wiring Diagram ACK-E-2009 Indoor Unit Outdoor Unit Model: ACK/A5CK 40E Model: ALC/A5LC 35/40C (1 Phase) 08024 105059...
  • Page 116 ACK-E-2009 Wiring Diagram Indoor Unit Outdoor Unit Model: ACK/A5CK 40/50E Model: ALC/A5LC 40/50C (3 Phase) 08024 105061...
  • Page 117 Wiring Diagram ACK-E-2009 Heat Pump Indoor Unit Outdoor Unit Model: ACK/A5CK 20/25/28ER Model: ALC/A5LC 20/25/28CR 08024 105062...
  • Page 118 ACK-E-2009 Wiring Diagram Indoor Unit Outdoor Unit Model: ACK 40ER Model: ALC 35/40CR (1 Phase) 08024 105063...
  • Page 119 Wiring Diagram ACK-E-2009 Indoor Unit Outdoor Unit Model: ACK 40/50ER Model: ALC 35/40CR (3 Phase) ALC 50CR 08024 105064...
  • Page 120 ACK-E-2009 Wiring Diagram Indoor Unit Outdoor Unit Model: A5CK 40ER Model: A5LC 35CR (1 Phase) 08024 105065...
  • Page 121 Wiring Diagram ACK-E-2009 Indoor Unit Outdoor Unit Model: A5CK 40ER Model: A5LC 40CR (1 Phase) 08024 105066...
  • Page 122 ACK-E-2009 Wiring Diagram Indoor Unit Outdoor Unit Model: A5CK 40/50ER Model: A5LC 35/40CR (3 Phase) A5LC 50CR 08024 105067...
  • Page 123: Service And Maintenance

    Service and Maintenance ACK-E-2009 Service and Maintenance Warning • Disconnect from main supply before servicing the air conditioner. • The unit is designed to give long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention. Components Maintenance Procedures Period...
  • Page 124 ACK-E-2009 Service and Maintenance For ALC Outdoor Models The design of the ALC outdoor series allows servicing to be carried out easily. The removal of the top, front and side panels makes almost every part accessible. Under normal circumstances, these outdoor units only require a check and cleaning of air intake coil surface once every 3 months.
  • Page 125: Troubleshooting

    Troubleshooting ACK-E-2009 Troubleshooting Error Code / Fault Condition When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before proceeding with the following troubleshooting procedures. The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which are not listed occur, contact your nearest local dealer.
  • Page 126 ACK-E-2009 Troubleshooting Diagnostic Guidelines By means of pressure reading: Data Pressure Probable cause Circuit High side 1. Overcharged with refrigerant. • Low side 2. Non-condensable gases in refrigerant circuit (e.g. air) • 3. Obstructed air-intake / discharge. 4. Hot air short circuiting in outdoor unit. High side 1.
  • Page 127: Troubleshooting

    Troubleshooting ACK-E-2009 By means of diagnostic fl ow chart: Generally, there are two kinds of problems, i.e. starting failure and insuffi cient cooling/heating. “Starting failure” is caused by electrical defect while improper application or defects in refrigerant circuit causes “Insuffi cient cooling / heating”.
  • Page 128 ACK-E-2009 Troubleshooting Change the contactor Coil burnt Faulty Condenser fan contactor Change the contacts Contact faulty Repair or replace the motor contactor Fan motor faulty Other electrical Repair or change if necessary component faulty Change the contactor Coil burnt Faulty Compressor contactor Change the contacts...
  • Page 129 Troubleshooting ACK-E-2009 ii ) Diagnosis of Refrigerant Circuit / Application There might be some causes where the unit starts running but does not perform satisfactorily, i.e. insuffi cient cooling. Judgement could be made by measuring temperature difference of indoor unit’s intake and discharge air as well as running current.
  • Page 130 ACK-E-2009 Troubleshooting Insuffi cient heating Indoor / outdoor coil dirty Clean the coil (clogged) Restricted circulation Clean the fi lter Indoor air fi lter dirty Change or repair the motor Fan motor malfunction Obstruction at air inlet / Remove the obstruction outlet of indoor / outdoor unit Windows / doors wide...
  • Page 131: Exploded View And Part List

    Exploded View and Part List ACK-E-2009 Exploded View and Part List INDOOR UNIT MODEL: ACK/A5CK 20/25/28E/ER 70024103951 Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
  • Page 132 No Description Part Number Assy. Base Pan R50013088907 13 Assy. Cover Terminal R50124103629 Assy. Coil Main 14 Support, Coil B R01014082313 ACK 20E/ER R50024101760 15 Cover, Wire A R12014091808 ACK 25E/ER R50024102942 16 Cover, Wire B R12014091809 ACK 28E/ER R50024102953...
  • Page 133 Exploded View and Part List ACK-E-2009 INDOOR UNIT MODEL: ACK/A5CK 40/50E/ER 70024104061 Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
  • Page 134 ACK-E-2009 Exploded View and Part List INDOOR UNIT MODEL: ACK/A5CK 40/50E/ER No Description Part Number No Description Part Number Assy. Base Pan R50013088907 Bracket, Hanger A R01024092644 Assy. Coil Bracket, Hanger B R01024092645 ACK 40E/ER R50024057753 Bracket, Hanger C R01024092779 ACK 50E/ER R50024036350 Assy.
  • Page 135 Exploded View and Part List ACK-E-2009 INDOOR UNIT MODEL: ACK-E/ER Panel 70024103952 No Description Part Number No Description Part Number Front, Frame R12014097197 10 Assy. LED R50044102825 Assy. Intake Grille R50124102823 Cover, Cross Connector R12014098030 Assy. Air Discharge Main R50124102820 12 Assy.
  • Page 136 ACK-E-2009 Exploded View and Part List OUTDOOR UNIT MODEL: ALC 20C No Description Part Number No Description Part Number Assy. Base Pan R50014078281 13 Top Panel R01014070596 Assy. Outdoor Coil 14 Assy. Front Grille R50124093631 ALC 18C R50024089940 15 Plastic Handle R12014057948 ALC 20C R50024084570...
  • Page 137 Exploded View and Part List ACK-E-2009 OUTDOOR UNIT MODEL: ALC 25/28C Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
  • Page 138 ACK-E-2009 Exploded View and Part List OUTDOOR UNIT MODEL: ALC 25/28C No Description Part Number No Description Part Number Assy. Base Pan 13 Top Panel R01014070596 ALC 25C R50014073884 14 Assy. Front Grille R50124093631 ALC 28C R50014090627 15 Plastic Handle, Side R12014057948 Assy.
  • Page 139 Exploded View and Part List ACK-E-2009 OUTDOOR UNIT MODEL: ALC 35/40/50C No Description Part Number No Description Part Number Assy. Base Pan R50014053238 11 Fan Motor Bracket R01014053232 Assy. 3 Way VLV 3/8” R50059030464 12 Panel Side Left R01010029899 Assy. 3 Way VLV 3/8” R50059030464 13 Fan Motor R03039004046...
  • Page 140 ACK-E-2009 Exploded View and Part List OUTDOOR UNIT MODEL: ALC 20CR No Description Part Number No Description Part Number Assy. Base Pan R50014078281 14 Assy. Front Grille R50124093631 Assy. Outdoor Coil R50024075143 15 Plastic Handle R12014057948 Bracket, Fan Motor R01014070601 16 Assy.
  • Page 141 Exploded View and Part List ACK-E-2009 OUTDOOR UNIT MODEL: ALC 25/28CR Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
  • Page 142 ACK-E-2009 Exploded View and Part List OUTDOOR UNIT MODEL: ALC 25/28CR No Description Part Number No Description Part Number Assy. Base Pan 13 Top Panel R01014070596 ALC 25CR R50014073884 14 Assy. Front Grille R50124093631 ALC 28CR R50014090627 15 Plastic Handle, Side R12014057948 Assy.
  • Page 143 Exploded View and Part List ACK-E-2009 OUTDOOR UNIT MODEL: ALC 35/40/50CR No Description Part Number No Description Part Number Assy. Base Pan R50014053238 14 Fan Blade R03013028160 Assy. 3 Way VLV 3/8” R50059030464 15 Front Panel R50014053236 Assy. 3 Way VLV 3/8” R50059030464 16 Valve Plate R01013029901...
  • Page 144 ACK-E-2009 Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 20C No Description Part Number No Description Part Number Assy. Base Pan R50014078281 14 Assy. Control Panel R50044086076 Assy. Outdoor Coil R50024079078 15 Top Panel R01014070596 Bracket, Fan Motor R01014070601 16 Assy.
  • Page 145 Exploded View and Part List ACK-E-2009 OUTDOOR UNIT MODEL: A5LC 25/28C Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
  • Page 146 ACK-E-2009 Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 25/28C No Description Part Number No Description Part Number Assy. Base Pan 12 Service Panel R01014070949 A5LC 25C R50014078281 13 Terminal Cover Panel R01014070838 A5LC 28C R50014073884 14 Assy. Control Panel Assy.
  • Page 147 Exploded View and Part List ACK-E-2009 OUTDOOR UNIT MODEL: A5LC 35/40/50C Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
  • Page 148 ACK-E-2009 Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 35/40/50C No Description Part Number No Description Part Number Assy. Base Pan R50014053238 Capacitor, Fan Motor Assy. 3 Way VLV 3/8” R50059017536 A5LC 35C R04029026782 Assy. 3 Way VLV 5/8” R50059030530 A5LC 40C R04029026761...
  • Page 149 Exploded View and Part List ACK-E-2009 OUTDOOR UNIT MODEL: A5LC 20CR No Description Part Number No Description Part Number Assy. Base Pan R50014078281 14 Assy. Control Panel R50044086136 Assy. Outdoor Coil R50024075143 15 Top Panel R01014070596 Bracket, Fan Motor R01014070601 16 Assy.
  • Page 150 ACK-E-2009 Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 20CR Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
  • Page 151 Exploded View and Part List ACK-E-2009 OUTDOOR UNIT MODEL: A5LC 25/28CR No Description Part Number No Description Part Number Assy. Base Pan 13 Terminal Cover Panel R01014070838 A5LC 25CR R50014078281 14 Assy. Control Panel A5LC 28CR R50014073884 A5LC 25CR R50044086076 Assy.
  • Page 152 ACK-E-2009 Exploded View and Part List OUTDOOR UNIT MODEL: A5LC 35/40/50CR Note: All exploded view and part list are subjected to change by the manufacturer without prior notice...
  • Page 153 Exploded View and Part List ACK-E-2009 OUTDOOR UNIT MODEL: A5LC 35/40/50CR No Description Part Number No Description Part Number Assy. Base Pan R50014053238 Capacitor, Fan Motor Assy. 3 Way VLV 3/8” R50059017536 A5LC 35CR R04029026782 Assy. 3 Way VLV 5/8” R50059030530 A5LC 40CR R04029026761...
  • Page 154 While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of speci fications andequipment are also subject to change to suit local conditions and equirements and not all models are available in every market.

Table of Contents