ComDeviceName
Valid values: COM1-COM16
Definition: This is the serial port that this instance of the control will use. If you have more than one base station,
drop in another Wdterm control and set its ComDeviceName for your other COM port(s).
ComBaudValue
Valid values: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200.
Definition: This is the serial port speed setting and must match the base station setting.
ComParity
Valid values: None, Even, Odd.
Definition: This is a serial port setting and must match the base station setting. WDterm may allow other settings
but those listed here are the only ones compatible with current version base stations.
ComDataBits
Valid values: 7, 8
Definition: This is a serial port setting and must match the base station setting. WDterm may allow other settings
but those listed here are the only ones compatible with current version base stations.
ComStopBits
Valid values: 1, 2.
Definition: This is a serial port setting and must match the base station setting. WDterm may allow other settings
but those listed here are the only ones compatible with current version base stations.
Quiet
Valid values: True, False.
Definition: If Quiet is set to True then any status and error message generated by WDterm will be suppressed.