Page 1
100275092_2000533999_Rev B ™ F I R E T U B E C O M B I Noble Combi Boiler User’s Information Manual Models: 110 - 199 WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
™ User’s Information Manual F I R E T U B E C O M B I Please read before proceeding The Noble Combi Boiler Installation Boiler service and maintenance – NOTICE and Service Manual is for use only by •...
™ User’s Information Manual F I R E T U B E C O M B I Prevent combustion air contamination If the boiler combustion air inlet is located WARNING Table 1 Corrosive Contaminants and Sources in any area likely to cause contamination, or if products which would contaminate Products to avoid: the air cannot be removed, you must have...
™ User’s Information Manual F I R E T U B E C O M B I Maintenance schedule Owner maintenance Service technician (see pages 6 - 8 for detailed instructions) • Check boiler area General: • Check pressure/temperature • Reported problems gauge Daily •...
™ User’s Information Manual F I R E T U B E C O M B I Maintenance schedule Maintenance procedures Read the list of potential materials listed in Table 1 on page 4 of this manual. If any of these products are in the Boiler must be serviced and maintained room from which the boiler takes its combustion air, they must be removed immediately or the boiler combustion...
™ User’s Information Manual F I R E T U B E C O M B I Maintenance schedule (continued) Clean/Inspect Trap Assembly Use materials approved by the authority NOTICE having jurisdiction. In the absence of other Remove the clean out cap on the bottom of the trap. Let authority, PVC and CPVC pipe must comply the condensate and any debris drain out.
™ User’s Information Manual F I R E T U B E C O M B I Maintenance schedule Test low water cutoff (if installed) Operate relief valve Before proceeding, verify that the relief valve outlet has If the system is equipped with a low water cutoff, test the been piped to a safe place of discharge, avoiding any low water cutoff periodically during the heating season, possibility of scalding from hot water.
™ User’s Information Manual F I R E T U B E C O M B I SMART SYSTEM control module Noble Combi Boiler control module Use the control panel (FIG. 4-1) to set temperatures, operating conditions, and monitor boiler operation. Figure 4-1 Control Panel DISPLAY WINDOW RESET BUTTON...
™ User’s Information Manual F I R E T U B E C O M B I SMART SYSTEM control module (continued) Set space heating operation Adjust DHW set point temperature Determine controlling sensor For space heating systems, the temperature control can be ◄...
™ User’s Information Manual F I R E T U B E C O M B I SMART SYSTEM control module Figure 4-2 Status Display Screen OPERATION DISPLAY 1. Once the gas pressure switch(es) are closed, the control turns on the appropriate pumps (system and boiler pumps for space heating, DHW pump for DHW).
Page 13
™ User’s Information Manual F I R E T U B E C O M B I SMART SYSTEM control module (continued) OPERATION DISPLAY 6. If flame is detected, it holds the firing rate steady for a few seconds to let the flame stabilize, then it begins to modulate the firing rate based on a set point or some other command.
Page 14
™ User’s Information Manual F I R E T U B E C O M B I Notes...
Page 15
™ User’s Information Manual F I R E T U B E C O M B I Notes...
Page 16
Revision A (PCP #3000004508 / CN #500004666) initial release. Revision B (PCP #3000005203 / CN #500005353) reflects the addition of the Noble logo. MM #100275092_DIR #2000533999_Rev B 11/16...