MECHANICAL INSTALLATION:
®
Verifact D and D-V microphones are designed to be installed in a single gang electrical box for flush or surface
mounting to a wall or ceiling. It should be positioned 3 to 6 ft. from the area of desired coverage. Ceiling heights in
excess of 10 ft. should be avoided.
MICROPHONE CONNECTION:
®
Verifact D and D-V Microphones connect directly to any Louroe Audio Base Station or to a Louroe Audio Interface
(Model IF-1, IF-2, IF-4 and IF-8). A small terminal block is located on the microphone pre-amp, and marked A, B,
C.
Using recommended cable, connect as follows:
MODEL D OR D-V MICROPHONE
CONNECTING VERIFACT D OR D-V MICROPHONE TO A LOUROE BASE STATION OR
AUDIO INTERFACE ADAPTER (IF-1, IF-4 or IF-8)
All Louroe base stations and audio interface adapters have a corresponding terminal block
marked A, B C for each audio zone. Bring in other end of cable from the microphone and connect
to the terminal block (or blocks) matching
Maximum cable run between microphone and base station/interface adapter is 1,000 ft.
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX
INSTALLATION AND OPERATING INSTRUCTIONS
Red wire connects to terminal A (+12Vdc)
Black wire connects to terminal B (audio output)
Bare wire connects to terminal C (ground)
If using cable from other manufacturers, color code may vary.
C
B
A
RED
®
®
website: www.louroe.com
BARE
BLACK
2 CONDUCTOR SHIELDED
22 GAUGE, with a 24 gauge drain wire
WEST PENN
452 OR EQUIVALENT
A to A
B to B
C to C
e-mail: sales@louroe.com
Page 2 of 4
WIRING REQUIREMENTS
2 Conductor shielded cable,
22 gauge with a 24 gauge
drain wire
BASE STATION
BARE
C
B
A
BLACK
RED
TO LOUROE
OR
AUDIO
INTERFACE
ADAPTER
(818)
994-6458
D/D-V-inst_12/14