Repair Flow Chart - Haier LE392D2320 Service Manual

Table of Contents

Advertisement

4. Repair Flow Chart

1. No power
No power (LED "Off")
Check the AC input and
the power is "ON"?
Yes
Power board
output=5/5.2V?
Yes
Check the IR board and LED
Replace the IR board
No
Replace the main board
No
Power "On"
No
Replace the power board
37