BACnet® Fixed Function Thermostat
FOR FAN COIL/HEAT PUMP/CONVENTIONAL SYSTEMS
Dimensions
The Fixed Function Thermostat consists of a mounting
plate and a circuit board with a plastic cover.
Fig. 1. Fixed Function Thermostat dimensions
INSTALLATION INSTRUCTIONS
APPLICATION
Honeywell's BACnet® Fixed Function Thermostat, BACnet
FF, is a configurable device with 19 pre-loaded
applications. The thermostat is a communicating,
intelligent sensor-controller combination with built-in
temperature and humidity sensors used to control
applications such as roof top units, fan-coil units and heat
pumps. The thermostat communicates over an MS/TP
LAN so it operates as a fully-functioning BACnet
controller and easily integrates with the building
automation system. The two available models are
TB3026B and TB3026B-W, which includes a wireless
sensor option.
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a
hazardous condition.
2. Check ratings given in instructions and on the
product to ensure the product is suitable for the
application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
operation as provided in these instructions.
MERCURY NOTICE
If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.
Contact your local waste management authority
for instructions regarding recycling and the proper
disposal of an old control. If you have questions,
contact Honeywell Customer Care Center.
CAUTION
Electrical Shock or Equipment Damage Hazard.
Can shock individuals or short equipment
circuitry.
Disconnect power supply before installation.
31-00093-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell TB3026B

  • Page 1 The thermostat communicates over an MS/TP LAN so it operates as a fully-functioning BACnet controller and easily integrates with the building automation system. The two available models are TB3026B and TB3026B-W, which includes a wireless sensor option. INSTALLATION When Installing this Product...
  • Page 2: Wiring The Wallplate

    BACNET® FIXED FUNCTION THERMOSTAT Location Do not install the thermostat where it can be affected by: — drafts or dead spots behind doors and in corners. — hot or cold air from ducts. — radiant heat from sun or appliances. —...
  • Page 3: Ms/Tp Lan Wiring

    BACNET® FIXED FUNCTION THERMOSTAT MS/TP LAN Wiring The BACnet FF communicates on the site-wide BACnet system over a twisted-pair MS/TP LAN, which uses the EIA–485 signaling standard. The BACnet FFs are master devices on the MS/TP LAN. Each BACnet FF employs a high-quality EIA–485 transceiver and exerts 1/4 unit load on the MS/TP LAN.
  • Page 4: Mounting Thermostat To Wallplate

    BACNET® FIXED FUNCTION THERMOSTAT Grounding the MS/TP LAN Shield Mounting Thermostat to Wallplate Proper shield grounding of the MS/TP cabling can help 1. Align the terminal screw blocks with the pins on the minimize the risk of communications problems and back of the thermostat.
  • Page 5: Installer Setup (Isu) Codes

    BACNET® FIXED FUNCTION THERMOSTAT TO SET THE MAC ADDRESS AND DEVICE INSTANCE AT 3. Use the down arrow next to the installer setup code THE DISPLAY to advance to ISU code 800. 1. From the home screen, press SYSTEM. Five blank 4.
  • Page 6 BACNET® FIXED FUNCTION THERMOSTAT Table 3. ISU Parameters. ISU Parameter Code Description Allowed Values Year, first 2 digits 19-21 Year, second 2 digits 00-99 (00-54 if ISU 200=21) Month 1-12 1-31 Schedule format BV-133 0 – not programmable (BV-133=0) 4 – 7 day programmable (BV-133=1) Backlight control BV-79 0 –...
  • Page 7: Field Service Mode

    Pairing a Sensor to a Wireless 5. Verify that the BACnet FF and sensor successfully paired. BACnet FF (TB3026B-W Only) Paired = sensor status is displayed, replacing --. Timed out = RESET is displayed and sensor status BACnet FFs and sensors ship unpaired, verified by two is --.
  • Page 8: Technical Data

    • BACnet Fixed Function Thermostat System loads are the maximum allowed (24VAC @ 0.5A). Actual Engineering Guide (Form No. 31-00098) power requirements depend on connected loads. Wireless Receiver (TB3026B-W only) 433.92 Mhz; range is 50 feet. Automation and Control Solutions Honeywell International Inc.

This manual is also suitable for:

Tb3026b-w

Table of Contents