TROUBLESHOOTING GUIDE
Fault Code
Fault D109: Motor
Controller Zero Cur-
rent
Fault D110: Motor
Controller
Overcurrent
Fault D111: Motor
Controller Voltage
Overload
Fault D112: Motor
Controller
Undervoltage
Fault D113: Motor
Controller Control
Fault
Fault D114: Lower
Board Incline Range
Fault
Category
Description
DC MCB
Low Incoming AC Voltage
DC MCB
High Incoming AC Voltage
DC MCB
Low Incoming AC Voltage
DC MCB
Low Incoming AC Voltage
Incline Stall - incline not
DC MCB
moving when commanded
DC MCB
Incline out of range
Truefitness.com / 800.426.6570 / 636.272.7100
(CONTINUED)
Cause
Low AC Line Voltage
High AC line voltage
Motor Control Board
High belt/deck
friction
Low AC Line Voltage
Low AC Line Voltage
Console displays Fault
Calibration not saved.
Incline disabled.
Incline Potentiometer
value out of range
Acme Nut jammed
Motor bearings
Console displays Fault
Calibration not saved.
Incline disabled.
Incline Potentiometer
value out of range
:
Corrective Action
Power cycle
Contact dealer or
TRUE service
Check AC line voltage
Power cycle
Contact dealer or
TRUE service
Lubricate treadbelt
Power cycle
Check AC line voltage
Contact dealer or
TRUE service
Power cycle
Check AC line voltage
Contact dealer or
TRUE service
Power cycle
Check cable
connections
Run incline calibration
Contact dealer or
TRUE service
Power cycle
Check cable
connections
Run incline calibration
Contact dealer or
TRUE service