7. Determine the status of all storage subsystems and components in the
8. Are the LEDs indicating normal operation, and is the status Optimal on all the
9. Diagnose and correct the fault by completing the following steps:

Firmware updates

Attention: Save the storage subsystem profile before performing any controller or
ESM firmware upgrades. Save the storage subsystem profile and all configuration
(*.cfg) files to a server disk that will remain accessible in the event of a DS3950
storage configuration failure. Do not save these files only to a LUN in the DS3950
Storage Subsystem.
To ensure the optimal operation of the DS3950 storage subsystem and its attached
storage expansion enclosures, the storage expansion enclosure ESM firmware, the
DS3950 controller firmware, the hard drive firmware, and the NVSRAM (for
controllers only) must be up- to-date. Go to the following Web site to get the latest
updates:
www.ibm.com/servers/storage/support/disk/
Refer to "Software and hardware compatibility and upgrades" on page 9 for
software and hardware compatibility information and requirements.
configuration by completing the following steps:
a. Check all LEDs on each component in the storage expansion enclosures.
Ensure that all the LEDs show normal status. For more information on LED
status for storage expansion enclosures, see "Checking the LEDs" on page
51 or the Installation, User's, and Maintenance Guide for your DS3950
storage expansion enclosure.
b. Check all LEDs on each component in the storage subsystem. Ensure that
all the LEDs show normal status. For information about LED status, see
"Solving problems" on page 93.
c. Open the DS Storage Manager Subsystem Management Window, and
display the Physical View for the configuration.
The status for each component will be either Optimal or Needs Attention.
d. Review the status of the configuration components shown in the Subsystem
Management Window by selecting the appropriate component button for
each storage subsystem.
configuration components?
v Yes — End of procedure.
v No — Go to step 9.
a. Run the DS Storage Manager Recovery Guru by selecting the Recovery
Guru toolbar button in the Subsystem Management window.
b. Complete the recovery procedure.
If the Recovery Guru directs you to replace a failed component, use the
individual LEDs on the storage subsystem to locate the specific failed
component. For troubleshooting procedures, see Chapter 6, "Hardware
maintenance," on page 93.
c. When the recovery procedure is completed, select Recheck in the Recovery
Guru. This action reruns the Recovery Guru to ensure that the problem has
been corrected.
d. If the problem persists, contact your IBM service representative.