Carrier 30GX Installation, Operation And Maintenance Instructions page 14

Screw-compressor air- and water-cooled liquid chillers
Table of Contents

Advertisement

ITEM INFORMATION TEMPERATURES PRESSURES
0
Operating
Evaporator
type
water entering
temperature
1
Mode
Evaporator
water leaving
temperature
2
Mode*
Copndenser
water entering
temperature*
3
Mode*
Condenser
water leaving
temperature*
4
Mode*
Reclaim
water entering
temperature*
5
Mode*
Reclaim
water leaving
temperature*
6
Cooling/heating* Saturated
discharge temp.
circuit A
7
Number of
Saturated
capacity
suction temp.
stages
circuit A
8
Present
Discharge gas
demand
temperature
limit in %
circuit A
9
Unit
Discharge
capacity
superheat,
in %
circuit A
10
Capacity
Motor
circuit A
temperature A1
11
Capacity
Motor
circuit B
temperature A2
in %*
12
Active
Saturated disch.
setpoint
temperature
compressor B
13
Control
Saturated suction
point
temperature
Ciucuit B
14
Active
Discharge temp.
condensing
circuit B*
setpoint*
15
Capacity
Discharge
override
superheat,
circuit B
16
EXV
Motor
override
temperature B1
17
hr_status
Motor
heat reclaim
temperature B2
mode
18
SMZ
Outdoor
temperature
19
ZM
-
Key:
* Displayed if the configuration requires it.
** Displayed if the alarm exists.
- Not in use.
14
SETPOINTS
INPUTS
Circuit A
Cooling
Remote
discharge
setpoint 1
start/stop
pressure
contact status
Circuit A
Cooling
Remote
suction
setpoint 2
stepoint contact
pressure
status
Oil pressure
Heating
Remote
A1*
setpoint*
heat/cool
contact status*
Oil pressure
Condensing
Remote
A2
setpoint*
reclaim operat.
contact status*
Oil differential
Reclaim
Capacity
pressure
setpoint*
reduction
compressor A1*
contact status*
Oil differential
Capacity
Evaporator
pressure
reduction
water flow
compressor A2*
setpoint as %
control contact
Economizer
Cooling
Condenser
pressure
loading
water flow
A1*
rate ramp
control contact
Economizer
Heating
Oil level
pressure
loading
circuit A
A2*
rate ramp*
Discharge
Cooling - 0-10 V
Oil level
pressure
d.c. signal for
circuit B
circuit B*
zero reset*
Suction
Cooling - 0-10 V
Water flow contr. Alarm circuit A
pressure
d.c. signal for
contact heat
circuit B*
full reset*
reclaim condenser B status
Oil pressure
Cooling - delta
Drain pressostat
B1*
temperature for
contact
circuit A
Oil pressure
Cooling - delta
Drain pressostat
B2*
temperature for
contact
full reset*
circuit B
Oil differential
Cooling -
Evaporator
pressure
full reset
fluid level
compressor B1
degrees value*
circuit A
Oil differential
Heating - 0-10 V
Evaporator
pressure
d.c. signal for
fluid level
compressor B2
zero reset*
circuit B
Economizer
Heating - 0-10 V
0-10 V
pressure
d.c. signal for
external signal
B1*
full reset*
Economizer
Heating - delta
-
pressure
temperature for
B2*
zero reset*
-
Heating - delta
-
temperature for
zero reset*
-
Heating - full
-
reset degrees
value*
-
-
-
-
-
-
OUTPUTS
CONFIGURATIONS ALARMS
Compressor
Password
Number of
status
active alarms/
resets
Loader
Master circuit
Active alarm
status
select*
code 1**
Motor cooling
Circuit
Active
valve status
loading
alarm code 2** alarm code 3**
circuit A
sequence*
Motor cooling
Delay at
Active
valve status
start-up
alarm code 3** alarm code 4**
circuit B
in minutes
Oil solenoid
Ramp
Active
status
loading
alarm code 4** alarm code 5**
selection
Oil heater
Setpoint
Active
status
reset
alarm code 5** alarm code 6**
selection
Oil pimp
Demand
-
status
limit
selection
Fan status
Software
-
A1 - A2 -
version
A3- A4
number
Fan status
ENO
-
B1 - B2 -
B3 - B4*
BUS
-
and alarm circuit
Position
-
-
EXV A in %*
Position
-
-
EXV B in %*
Fan speed/
-
-
valve position
circuit A in %*
Fan speed
-
-
circuit B
in %*
Evaporator and
-
-
condenser pump
status
Evaporator and
-
-
reclaim cond.
heater status
Reclaim cond.
-
-
water valve
position in %
Heat reclaim
-
-
solenoid valve
status
Local test
-
-
interface
-
-
-
ALARMS HIST.
OPERATING LOG
Historic
Unit
alarm code 1**
operating
hours/10
Historic
Circuit A
alarm code 2**
operating
hours/10
Historic
Compressor A1
operating
hours/10*
Historic
Compressor A2
operating
hours/10*
Hisotric
Compressor B
operating
hours/10*
Historic
Compressor B1
operating
hours/10*
Historic
Compressor B2
alarm code 7**
operating
hours/10*
Historic
Number of
alarm code 8**
units
start-ups/10*
Historic
Number of
alarm code 9**
compressor A1
start-ups/10*
Historic
Number of
alarm code 10**
compressor A2
start-ups/10*
-
Number of
compressor A2
star-ups/10
-
Number of
compressor B1
start-ups/10*
-
Number of
compressor B2
start-ups/10*
-
Max. number of
start-ups
last hour
-
Max. number of
average start-ups
last 24 hours
-
-
-
-
-
-
-
-
-
-

Hide quick links: